2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/DL/T 403-2000
DL/T 403-2000   HV vacuum circuit-breaker for rated voltage 12kv to 40.5kv (English Version)
Standard No.: DL/T 403-2000 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 7000 words Translation Price(USD):170.0 remind me the price change

Email:

Implemented on:2001-1-1 Delivery: via email in 1 business day

→ → →

2018-03-01,2018-3-1,2001-1-1,14113736164476955A4C9AC4DA5AC
Standard No.: DL/T 403-2000
English Name: HV vacuum circuit-breaker for rated voltage 12kv to 40.5kv
Chinese Name: 12kV-40.5kV高压真空断路器订货技术条件
Chinese Classification: K43    High voltage switchgear
Professional Classification: DL    Professional Standard - Electricity
Source Content Issued by: SETC
Issued on: 2000-11-3
Implemented on: 2001-1-1
Status: superseded
Superseded by:DL/T 403-2017 High-voltage alternating-current vacuum circuit-breaker
Superseded on:2018-3-1
Abolished on:2018-03-01
Superseding:DL/T 403-1991 Indoor HV Vacuum Circuit-Breaker for Rated Voltage 10kv to 35kv
Target Language: English
File Format: PDF
Word Count: 7000 words
Translation Price(USD): 170.0
Delivery: via email in 1 business day
1 Scope This standard specifies the service conditions, parameters, structures, technical requirements and test items of HV vacuum circuit-breakers. This standard is applicable to three-phase and single-phase HV vacuum circuit-breakers (hereinafter referred to as vacuum circuit-breakers) with rated voltage 12kV~40.5kV and frequency 50Hz and their fitted vacuum interrupters (hereinafter referred to as interrupters, also called switching tubes).This product is mainly used for the protection and control in the power plant, AC distribution system and transformer substation as well as such locations as transformer substations of industrial and mining enterprises. Note: The generator circuit-breaker shall not be included. 2 Normative References The following normative documents contain provisions which, through reference in this standard, constitute provisions of this standard. At time of publication, the editions indicated were valid. All the standards will be revised, all parties coming to an agreement according to this standard are encouraged to study whether the latest editions of the following standards are applicable.
Foreword I 1 Scope 2 Normative References 3 Normal and Particular Service Requirements 4 Rated Parameters 5 Structural and Technical Requirements 6 Type Tests 7 Delivery Tests 8 Marking, Packaging, Transport and Storage
Referred in DL/T 403-2000:
*GB 311.1-1997 Insulation co-ordination for high voltage transmission and distribution equipment
*GB/T 2423.1-1989
*GB/T 2423.4-1993 Basic environmental testing procedures for electric and electronic products-Test Db: Damp heat, cyclic
*-
*-
*GB/T 3309-1989 Mechanical test at ambient temperature for high-voltage switchgear
*GB/T 11022-1999 Common specifications for high-voltage switchgear and controlgear standards
*GB/T 16927.1-1997 Hign voltsge test techniques - Part 1: General test requirements
*DL/T 402-1999 High-Voltage Alternating Current Circuit-Breakers
*DL/T 593-1996 Common Specifications for HV Switchgear
*JB 8738-1998
DL/T 403-2000 is referred in:
* GB 50147-2010 High-Voltage Electric Equipment Installation Engineering
* GB 50147-2010 High-Voltage Electric Equipment Installation Engineering
Code of China
Standard
DL/T 403-2000   HV vacuum circuit-breaker for rated voltage 12kv to 40.5kv (English Version)
Standard No.DL/T 403-2000
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count7000 words
Price(USD)170.0
Implemented on2001-1-1
Deliveryvia email in 1 business day
Detail of DL/T 403-2000
Standard No.
DL/T 403-2000
English Name
HV vacuum circuit-breaker for rated voltage 12kv to 40.5kv
Chinese Name
12kV-40.5kV高压真空断路器订货技术条件
Chinese Classification
K43
Professional Classification
DL
ICS Classification
Issued by
SETC
Issued on
2000-11-3
Implemented on
2001-1-1
Status
superseded
Superseded by
DL/T 403-2017 High-voltage alternating-current vacuum circuit-breaker
Superseded on
2018-3-1
Abolished on
2018-03-01
Superseding
DL/T 403-1991 Indoor HV Vacuum Circuit-Breaker for Rated Voltage 10kv to 35kv
Language
English
File Format
PDF
Word Count
7000 words
Price(USD)
170.0
Keywords
DL/T 403-2000, DL 403-2000, DLT 403-2000, DL/T403-2000, DL/T 403, DL/T403, DL403-2000, DL 403, DL403, DLT403-2000, DLT 403, DLT403
Introduction of DL/T 403-2000
1 Scope This standard specifies the service conditions, parameters, structures, technical requirements and test items of HV vacuum circuit-breakers. This standard is applicable to three-phase and single-phase HV vacuum circuit-breakers (hereinafter referred to as vacuum circuit-breakers) with rated voltage 12kV~40.5kV and frequency 50Hz and their fitted vacuum interrupters (hereinafter referred to as interrupters, also called switching tubes).This product is mainly used for the protection and control in the power plant, AC distribution system and transformer substation as well as such locations as transformer substations of industrial and mining enterprises. Note: The generator circuit-breaker shall not be included. 2 Normative References The following normative documents contain provisions which, through reference in this standard, constitute provisions of this standard. At time of publication, the editions indicated were valid. All the standards will be revised, all parties coming to an agreement according to this standard are encouraged to study whether the latest editions of the following standards are applicable.
Contents of DL/T 403-2000
Foreword I 1 Scope 2 Normative References 3 Normal and Particular Service Requirements 4 Rated Parameters 5 Structural and Technical Requirements 6 Type Tests 7 Delivery Tests 8 Marking, Packaging, Transport and Storage
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords: