DL/T 5056-1996   Technical Code of General Plan Design for Substation (English Version)
Standard No.: DL/T 5056-1996 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 10000 words Translation Price(USD):250.0 remind me the price change

Email:

Implemented on:1997-1-1 Delivery: via email in 1 business day

→ → →

,2008-6-1,1997-1-1,14113731203823204E33C1FEDA0AC
Standard No.: DL/T 5056-1996
English Name: Technical Code of General Plan Design for Substation
Chinese Name: 变电所总布置技术设计规程
Professional Classification: DL    Professional Standard - Electricity
Source Content Issued by: Ministry of Power Industry
Issued on: 1996-08-26
Implemented on: 1997-1-1
Status: superseded
Superseded by:DL/T 5056-2007 Technical code of general plan design for substation
Superseded on:2008-6-1
Target Language: English
File Format: PDF
Word Count: 10000 words
Translation Price(USD): 250.0
Delivery: via email in 1 business day
1.0.1 The design of the substation general plan shall comprehensively implement the national project construction guidelines and policies and observe design principles and technical specifications stated herein. The design shall adapt the national situation and meet targets of the state-of-the-art technology and safety production, to obtain notable overall economic benefits. 1.0.2 This Code is applicable to the design of newly-built and extended 110-500kV substations. 1.0.3 The design of the substation general plan shall save land, rationally utilize terrain according to local conditions and decrease the site grading quantities and the relocation of facilities like buildings and structures. The design proposal shall be optimized after the technical comparison and argumentation. 1.0.4 This Code has been established guided by the principles stated in Code for Design of General Plan of Industrial Enterprises (GB50187-93). The design of substation general plan shall be in accordance with this Code as well as provisions stated in current concerned national and industrials standards. Substations constructed in special natural conditions, like the seismic areas, the collapsible loess region, the swelling soil region, soft ground, water congealed ground areas, shall meet provisions in the related national standards.
Preface 3 1. General Provisions 5 2. General Planning 5 3. General Layout 6 3.1 General Provisions 6 3.2 Main Buildings and Structures 7 3.3 Auxiliary and Outbuildings 8 3.4 Fences and Passageways 9 3.5 Spacing of Buildings and Structures 9 4. Vertical Layout 12 4.1 General Provisions 12 4.2 Determination of Design Elevation 13 4.3 Step Allocation 14 4.4 Site Drainage 18 4.5 Earthwork/Stonework 19 5. Arrangement of Pipe and Trench 21 5.1 General Provision 21 5.2 Underground Pipeline 22 5.3 Overhead Pipeline 25 5.4 Groove 26 6. Road 27 6.1 General Provisions 27 6.2 Substation-entrance Road 28 6.3 Roads in Substation 29 7. Treatment and Landscaping of Power Distribution Unit Site 30 7.1 Treatment of Power Distribution Unit Site 30 7.2 Landscaping 30 8. Technical and Economic Indices 31 Annex A Explanations of Terms in This Code 34 List of Compiling Unit, Participating Unit and Rapporteur 35
DL/T 5056-1996 is referred in:
* DL/T 5218-2005 Technical code for designing 220kV~500kV substation
Code of China
Standard
DL/T 5056-1996  Technical Code of General Plan Design for Substation (English Version)
Standard No.DL/T 5056-1996
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count10000 words
Price(USD)250.0
Implemented on1997-1-1
Deliveryvia email in 1 business day
Detail of DL/T 5056-1996
Standard No.
DL/T 5056-1996
English Name
Technical Code of General Plan Design for Substation
Chinese Name
变电所总布置技术设计规程
Chinese Classification
Professional Classification
DL
ICS Classification
Issued by
Ministry of Power Industry
Issued on
1996-08-26
Implemented on
1997-1-1
Status
superseded
Superseded by
DL/T 5056-2007 Technical code of general plan design for substation
Superseded on
2008-6-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
10000 words
Price(USD)
250.0
Keywords
DL/T 5056-1996, DL 5056-1996, DLT 5056-1996, DL/T5056-1996, DL/T 5056, DL/T5056, DL5056-1996, DL 5056, DL5056, DLT5056-1996, DLT 5056, DLT5056
Introduction of DL/T 5056-1996
1.0.1 The design of the substation general plan shall comprehensively implement the national project construction guidelines and policies and observe design principles and technical specifications stated herein. The design shall adapt the national situation and meet targets of the state-of-the-art technology and safety production, to obtain notable overall economic benefits. 1.0.2 This Code is applicable to the design of newly-built and extended 110-500kV substations. 1.0.3 The design of the substation general plan shall save land, rationally utilize terrain according to local conditions and decrease the site grading quantities and the relocation of facilities like buildings and structures. The design proposal shall be optimized after the technical comparison and argumentation. 1.0.4 This Code has been established guided by the principles stated in Code for Design of General Plan of Industrial Enterprises (GB50187-93). The design of substation general plan shall be in accordance with this Code as well as provisions stated in current concerned national and industrials standards. Substations constructed in special natural conditions, like the seismic areas, the collapsible loess region, the swelling soil region, soft ground, water congealed ground areas, shall meet provisions in the related national standards.
Contents of DL/T 5056-1996
Preface 3 1. General Provisions 5 2. General Planning 5 3. General Layout 6 3.1 General Provisions 6 3.2 Main Buildings and Structures 7 3.3 Auxiliary and Outbuildings 8 3.4 Fences and Passageways 9 3.5 Spacing of Buildings and Structures 9 4. Vertical Layout 12 4.1 General Provisions 12 4.2 Determination of Design Elevation 13 4.3 Step Allocation 14 4.4 Site Drainage 18 4.5 Earthwork/Stonework 19 5. Arrangement of Pipe and Trench 21 5.1 General Provision 21 5.2 Underground Pipeline 22 5.3 Overhead Pipeline 25 5.4 Groove 26 6. Road 27 6.1 General Provisions 27 6.2 Substation-entrance Road 28 6.3 Roads in Substation 29 7. Treatment and Landscaping of Power Distribution Unit Site 30 7.1 Treatment of Power Distribution Unit Site 30 7.2 Landscaping 30 8. Technical and Economic Indices 31 Annex A Explanations of Terms in This Code 34 List of Compiling Unit, Participating Unit and Rapporteur 35