2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 30864-2014
GB 30864-2014   Respiratory protection―Powered air-purifying respirator (English Version)
Standard No.: GB 30864-2014 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 21000 words Translation Price(USD):340.0 remind me the price change

Email:

Implemented on:2015-6-1 Delivery: via email in 1 business day

→ → →

,,2015-6-1,7794DA22D03B81021433312607271
Standard No.: GB 30864-2014
English Name: Respiratory protection―Powered air-purifying respirator
Chinese Name: 呼吸防护 动力送风过滤式呼吸器
Chinese Classification: C73    Articles for labor protection
Professional Classification: GB    National Standard
ICS Classification: 13.340.30 13.340.30    Respiratory protective devices 13.340.30
Source Content Issued by: AQSIQ; SAC
Issued on: 2014-07-24
Implemented on: 2015-6-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 21000 words
Translation Price(USD): 340.0
Delivery: via email in 1 business day
1 Scope This standard specifies the classification, labelling, technical requirements, test methods and identification of powered air-purifying respirators. This standard is applicable to powered air-purifying respirators preventing particles, toxic and harmful gas or vapor. This standard is not applicable to respirators used in combustible, explosive and oxygen-deficient environment and for escape. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2428 Head-face Dimensions of Adults GB 2626-2006 Respiratory Protective Equipment - Non-powered Air-purifying Particle Respirator GB 2811-2007 Safety Helmet GB 2890-2009 Respiratory Protection - Non-powered Air-purifying Respirators GB/T 3609.1-2008 Occupational Eye and Face Protection - Welding Protection - Part 1: Welding Protector GB/T 3609.2-2009 Occupational Eye and Face Protection - Welding Protection - Part 2: Automatic Welding Filter GB/T 3785.1-2010 Electroacoustics - Sound Level Meters - Part 1: Specifications GB 3836.1-2010 Explosive Atmospheres - Part 1: Equipment - General Requirements GB 3836.4-2010 Explosive Atmospheres - Part 4: Equipment Protection by Intrinsic Safety "i" GB/T 5703 Basic Human Body Measurements for Technological Design GB 12476.4-2010 Electrical Apparatus for Use in the Presence of Combustible Dust - Part 4: Protection by Intrinsic Safety “iD” GB/T 12903-2008 Personal Protective Equipment - Terminology GB 14866-2006 The Specifications for Personal Eye-protectors GB/T 18664-2002 Selection, Use and Maintenance of Respiratory Protective Equipment GB/T 23465-2009 Respiratory Protective Equipment - Practical Performance Evaluation Methods IEC 61241.1: 2004 Electrical Apparatus for Use in the Presence of Combustible Dust - Part 1: Protection by Enclosures "tD" 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 12903-2008 and the following apply. 3.1 powered air-purifying respirator; PAPR the air-purifying respirator overcoming component resistance by air flow provided by electric fan 3.2 positive pressure in any respiratory cycle, the internal pressure of such components as respirator facepiece, hood and breathing hose shall not be less than the ambient atmospheric pressure 3.3 negative pressure in any air suction cycle, the internal pressure of such components as respirator facepiece and breathing hose may be less than the ambient atmospheric pressure. 3.4 tight-fitting facepiece the protective facepiece isolating the respiratory tract from ambient air by tightly fitting with the wearer's facial skin. Tight-fitting facepieces are classified into half facepieces and full facepieces. 3.5 half facepiece the tight-fitting facepiece capable of covering mouth and nose, or covering mouth, nose and lower jaw [GB 2626-2006, as defined in 3.8] 3.6 full facepiece the tight-fitting facepiece capable of covering mouth, nose, eyes and lower jaw [GB 2626-2006, as defined in 3.9] 3.7 loose-fitting facepiece the loose-fitting air introduction unit used for positive pressure respirator, which only covers eyes, nose and mouth and tightly fits with face in part Note: as defined in 5.2.2.1 of modified GB/T 12903-2008. 3.8 loose-fitting hood the loose-fitting air introduction unit used for positive pressure respirator, which is able to completely cover head, neck and part of the shoulder or is used together with protective clothing Note: as defined in 3.1.12 of modified GB/T 18664-2002. 3.9 breathing hose
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Labelling 4.1 Classification and Labelling of Powered Air-purifying Respirator (PAPR) 4.2 Classification, Labelling and Tinting of PAPR Filter Elements 5 Technical Requirements 5.1 General Requirements 5.2 Tight-fitting Facepiece 5.3 Loose-fitting Facepiece and Loose-Fitting Hood 5.4 Manufacturer’s Minimum Design Flow Rate (MMDF) and Manufacturer's Design Duration 5.5 Respiratory Resistance 5.6 Visor 5.7 Inward Leakage 5.8 Breathing Hose 5.9 Dead Space 5.10 Filter Element 5.11 Strength of Connecting Component 5.12 Noise 5.13 Flammability 5.14 Checking Device 5.15 Warning Device 5.16 Intrinsic Safety and Electrical Part 5.17 Mass 5.18 Practical Performance 5.19 Requirements for Fire-fighting PAPR 5.20 Information to be Provided by the Manufacturer 6 Test 6.1 Samples and Ambient Conditions of Test 6.2 Visual Checking 6.3 Pretreatment 6.4 Actual Flow Rate and Manufacturer's Design Duration 6.5 Respiratory Resistance 6.6 Visual Field 6.7 Mechanical Strength of Visor 6.8 Inward Leakage 6.9 Compression Resistance of Breathing Hose Hose 6.10 Dead Space 6.11 Filter Efficiency 6.12 Protective Time 6.13 Resistance of Multiple Filter Elements 6.14 Interactive Flow Rate of PAPR with Tight-fitting Facepiece 6.15 Tensile Strength 6.16 Noise 6.17 Flammability 6.18 Mass 6.19 Practical Performance 7 Identification 7.1 Identification Content 7.2 Identification Location Annex A (Normative) Test Methods for Electrical Insulation and Heat Resistance of Respirator Facepiece or Hood for Welding Protection Annex B (Informative) Application of Warning Device Annex C (Informative) Description on PAPR Application in Fire Fighting Annex D (Informative) Summary of Requirements for Test Sample Annex E (Normative) Assembly Method of Loose-fitting Hood (with Neck Sealing Design) with or without Head Fixing Device References Figure 1 Schematic Diagram for Test System of Actual Flow Rate of PAPR with Tight-fitting Facepiece Figure 2 Schematic Diagram for Test System of Actual Flow Rate of PAPR with Loose-fitting Hood with Neck Sealed Figure 3 Schematic Diagram for Test System of Actual Flow Rate of PAPR with Air Supply Fan inside Loose-fitting Facepiece Figure 4 Schematic Diagram for Test System of Actual Flow Rate of PAPR with Air Supply Fan outside Loose-fitting Facepiece Figure 5 Diagram for the Arrangement of Sampling Tube of Soft Hood Figure 6 Schematic Diagram for Test Device of Compression Resistance of Breathing Figure 7 Schematic Diagram for Test System of Interactive Flow Rate Figure 8 Schematic Diagram for Flammability Detection Device Figure E.1 Necklace with Regulable Flow Figure E.2 Schematic Diagram for the Test Method with Head Fixing Device Table 1 Classification and Labelling of PAPR Table 2 Classification, Tinting, Labelling and Prevented Pollutant Examples of PAPR Filter Elements Table 3 Technical Requirements for PAPR Inward Leakage Table 4 Requirements for the Protective Time of Types A/B/E/K Filter Elements Table 5 Requirements for the Protective Time of Type NO/Hg Filter Element Table 6 Requirements for the Protective Time of Type AN Filter Element Table 7 Requirements for the Protective Time of Type SX Filter Element Table 8 Requirements for the Protective Time of Type CO Filter Element Table 9 Strength Requirements for Connection and Connecting Component Table 10 Visual Field Assessment Table D.1 Summary of Sample Requirements in the Test Methods
GB 30864-2014 is referred in:
*GB 42302-2022 Respiratory protection—Non-powered air-purifying respirators for escape
*GB 2890-2022 Respiratory protection—Non-powered air-purifying respirators
Code of China
Standard
GB 30864-2014  Respiratory protection―Powered air-purifying respirator (English Version)
Standard No.GB 30864-2014
Statusvalid
LanguageEnglish
File FormatPDF
Word Count21000 words
Price(USD)340.0
Implemented on2015-6-1
Deliveryvia email in 1 business day
Detail of GB 30864-2014
Standard No.
GB 30864-2014
English Name
Respiratory protection―Powered air-purifying respirator
Chinese Name
呼吸防护 动力送风过滤式呼吸器
Chinese Classification
C73
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2014-07-24
Implemented on
2015-6-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
21000 words
Price(USD)
340.0
Keywords
GB 30864-2014, GB/T 30864-2014, GBT 30864-2014, GB30864-2014, GB 30864, GB30864, GB/T30864-2014, GB/T 30864, GB/T30864, GBT30864-2014, GBT 30864, GBT30864
Introduction of GB 30864-2014
1 Scope This standard specifies the classification, labelling, technical requirements, test methods and identification of powered air-purifying respirators. This standard is applicable to powered air-purifying respirators preventing particles, toxic and harmful gas or vapor. This standard is not applicable to respirators used in combustible, explosive and oxygen-deficient environment and for escape. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2428 Head-face Dimensions of Adults GB 2626-2006 Respiratory Protective Equipment - Non-powered Air-purifying Particle Respirator GB 2811-2007 Safety Helmet GB 2890-2009 Respiratory Protection - Non-powered Air-purifying Respirators GB/T 3609.1-2008 Occupational Eye and Face Protection - Welding Protection - Part 1: Welding Protector GB/T 3609.2-2009 Occupational Eye and Face Protection - Welding Protection - Part 2: Automatic Welding Filter GB/T 3785.1-2010 Electroacoustics - Sound Level Meters - Part 1: Specifications GB 3836.1-2010 Explosive Atmospheres - Part 1: Equipment - General Requirements GB 3836.4-2010 Explosive Atmospheres - Part 4: Equipment Protection by Intrinsic Safety "i" GB/T 5703 Basic Human Body Measurements for Technological Design GB 12476.4-2010 Electrical Apparatus for Use in the Presence of Combustible Dust - Part 4: Protection by Intrinsic Safety “iD” GB/T 12903-2008 Personal Protective Equipment - Terminology GB 14866-2006 The Specifications for Personal Eye-protectors GB/T 18664-2002 Selection, Use and Maintenance of Respiratory Protective Equipment GB/T 23465-2009 Respiratory Protective Equipment - Practical Performance Evaluation Methods IEC 61241.1: 2004 Electrical Apparatus for Use in the Presence of Combustible Dust - Part 1: Protection by Enclosures "tD" 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 12903-2008 and the following apply. 3.1 powered air-purifying respirator; PAPR the air-purifying respirator overcoming component resistance by air flow provided by electric fan 3.2 positive pressure in any respiratory cycle, the internal pressure of such components as respirator facepiece, hood and breathing hose shall not be less than the ambient atmospheric pressure 3.3 negative pressure in any air suction cycle, the internal pressure of such components as respirator facepiece and breathing hose may be less than the ambient atmospheric pressure. 3.4 tight-fitting facepiece the protective facepiece isolating the respiratory tract from ambient air by tightly fitting with the wearer's facial skin. Tight-fitting facepieces are classified into half facepieces and full facepieces. 3.5 half facepiece the tight-fitting facepiece capable of covering mouth and nose, or covering mouth, nose and lower jaw [GB 2626-2006, as defined in 3.8] 3.6 full facepiece the tight-fitting facepiece capable of covering mouth, nose, eyes and lower jaw [GB 2626-2006, as defined in 3.9] 3.7 loose-fitting facepiece the loose-fitting air introduction unit used for positive pressure respirator, which only covers eyes, nose and mouth and tightly fits with face in part Note: as defined in 5.2.2.1 of modified GB/T 12903-2008. 3.8 loose-fitting hood the loose-fitting air introduction unit used for positive pressure respirator, which is able to completely cover head, neck and part of the shoulder or is used together with protective clothing Note: as defined in 3.1.12 of modified GB/T 18664-2002. 3.9 breathing hose
Contents of GB 30864-2014
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Labelling 4.1 Classification and Labelling of Powered Air-purifying Respirator (PAPR) 4.2 Classification, Labelling and Tinting of PAPR Filter Elements 5 Technical Requirements 5.1 General Requirements 5.2 Tight-fitting Facepiece 5.3 Loose-fitting Facepiece and Loose-Fitting Hood 5.4 Manufacturer’s Minimum Design Flow Rate (MMDF) and Manufacturer's Design Duration 5.5 Respiratory Resistance 5.6 Visor 5.7 Inward Leakage 5.8 Breathing Hose 5.9 Dead Space 5.10 Filter Element 5.11 Strength of Connecting Component 5.12 Noise 5.13 Flammability 5.14 Checking Device 5.15 Warning Device 5.16 Intrinsic Safety and Electrical Part 5.17 Mass 5.18 Practical Performance 5.19 Requirements for Fire-fighting PAPR 5.20 Information to be Provided by the Manufacturer 6 Test 6.1 Samples and Ambient Conditions of Test 6.2 Visual Checking 6.3 Pretreatment 6.4 Actual Flow Rate and Manufacturer's Design Duration 6.5 Respiratory Resistance 6.6 Visual Field 6.7 Mechanical Strength of Visor 6.8 Inward Leakage 6.9 Compression Resistance of Breathing Hose Hose 6.10 Dead Space 6.11 Filter Efficiency 6.12 Protective Time 6.13 Resistance of Multiple Filter Elements 6.14 Interactive Flow Rate of PAPR with Tight-fitting Facepiece 6.15 Tensile Strength 6.16 Noise 6.17 Flammability 6.18 Mass 6.19 Practical Performance 7 Identification 7.1 Identification Content 7.2 Identification Location Annex A (Normative) Test Methods for Electrical Insulation and Heat Resistance of Respirator Facepiece or Hood for Welding Protection Annex B (Informative) Application of Warning Device Annex C (Informative) Description on PAPR Application in Fire Fighting Annex D (Informative) Summary of Requirements for Test Sample Annex E (Normative) Assembly Method of Loose-fitting Hood (with Neck Sealing Design) with or without Head Fixing Device References Figure 1 Schematic Diagram for Test System of Actual Flow Rate of PAPR with Tight-fitting Facepiece Figure 2 Schematic Diagram for Test System of Actual Flow Rate of PAPR with Loose-fitting Hood with Neck Sealed Figure 3 Schematic Diagram for Test System of Actual Flow Rate of PAPR with Air Supply Fan inside Loose-fitting Facepiece Figure 4 Schematic Diagram for Test System of Actual Flow Rate of PAPR with Air Supply Fan outside Loose-fitting Facepiece Figure 5 Diagram for the Arrangement of Sampling Tube of Soft Hood Figure 6 Schematic Diagram for Test Device of Compression Resistance of Breathing Figure 7 Schematic Diagram for Test System of Interactive Flow Rate Figure 8 Schematic Diagram for Flammability Detection Device Figure E.1 Necklace with Regulable Flow Figure E.2 Schematic Diagram for the Test Method with Head Fixing Device Table 1 Classification and Labelling of PAPR Table 2 Classification, Tinting, Labelling and Prevented Pollutant Examples of PAPR Filter Elements Table 3 Technical Requirements for PAPR Inward Leakage Table 4 Requirements for the Protective Time of Types A/B/E/K Filter Elements Table 5 Requirements for the Protective Time of Type NO/Hg Filter Element Table 6 Requirements for the Protective Time of Type AN Filter Element Table 7 Requirements for the Protective Time of Type SX Filter Element Table 8 Requirements for the Protective Time of Type CO Filter Element Table 9 Strength Requirements for Connection and Connecting Component Table 10 Visual Field Assessment Table D.1 Summary of Sample Requirements in the Test Methods
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 30864-2014, GB/T 30864-2014, GBT 30864-2014, GB30864-2014, GB 30864, GB30864, GB/T30864-2014, GB/T 30864, GB/T30864, GBT30864-2014, GBT 30864, GBT30864