GB/T 18380.2-2001   Tests on electric cables under fire conditions-Part 2:Test on a single small vertical insulated copper wire or cable (English Version)
Standard No.: GB/T 18380.2-2001 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 1500 words Translation Price(USD):184.0 remind me the price change

Email:

Implemented on:2001-12-1 Delivery: via email in 1~3 business day

→ → →

2009-04-01,2009-4-1,2001-12-1,574E19542CFC331B1482809737534
Standard No.: GB/T 18380.2-2001
English Name: Tests on electric cables under fire conditions-Part 2:Test on a single small vertical insulated copper wire or cable
Chinese Name: 电缆在火焰条件下的燃烧试验 第2部分:单根铜心绝缘细电线或电缆垂直燃烧试验方法
Chinese Classification: K13    Cable and its accessory
Professional Classification: GB    National Standard
ICS Classification: 29.060.20 29.060.20    Cables 29.060.20
Source Content Issued by: AQSIQ
Issued on: 2001-07-12
Implemented on: 2001-12-1
Status: superseded
Superseded by:GB/T 18380.21-2008 Tests on electric and optical fibre cables under fire conditions - Part 21: Test for vertical flame propagation for a single small insulated wire or cable - Apparatus
Superseded on:2009-4-1
Abolished on:2009-04-01
Superseding:GB 12666.2-1990
Target Language: English
File Format: PDF
Word Count: 1500 words
Translation Price(USD): 184.0
Delivery: via email in 1~3 business day
Tests on Electric Cables under Fire Conditions — Part 2: Test on a Single Small Vertical Insulated Copper Wire or Cable 1 Scope This standard specifies a method of testing a small insulated wire under_ fire conditions when the method specified in GB/T 18380.1 is not suitable because some small conductors may melt during the application of the flame. The range of application. recommended is for solid copper conductors from 0.4 mm to 0.8 mm diameter and for stranded conductors from 0.1 mm2 to 0.5 mm2. cross-section. This standard includes the requirement for compliance. Note: The use of insulated wire which complies with this standard is not sufficient to prevent flame propagation under all conditions of installation. When the risk of propagation is high, such as with long. vertical runs of bunches of wires, it cannot be assumed that because a sample complies with this standard the bunch will behave in a similar manner. 2 Performance Requirement The test is intended for type approval testing or may be referred to in cable standards. One sample of insulated wire or cable, after having. been tested in accordance with Clauses 6, 7 and 8, shall comply with the following requirement: After all burning has ceased, the surface of the sample shall be wiped clean and the charred portion shall not have reached within 50 mm of the lower edge of the top clamp. 3 Test Equipment a) Propane burner complying with the requirements of Figure 1. It is allowable to fit an adaptor to burners not exactly complying with the figure in order to obtain the 8 mm bore shown. b) Propane bottle with pressure device and pressure gauge. c) Metal screen (1200 ± 25) mm high; (300 ± 25) mm wide and (450 ± 25) mm deep, with open front and closed top and bottom (see Figure 3). d) Stop watch. e) Electrically heated oven. 4 Sample
1 Scope 2 Performance Requirement 3 Test Equipment 4 Sample 5 Conditioning Before Test 6 Test Conditions 7 Source of Heat 8 Test Procedure
GB/T 18380.2-2001 is referred in:
*GB/T 12528-2008 Rail vehicle cables with rated voltages up to and including 3kV
*JB/T 10491.1-2004 Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V Part1: General requirements
*JB/T 10491.2-2004 Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V Part2:
*GB/T 18380.3-2001 Tests on electric cables under fire conditions-Part 3:Tests on bunched wires or cables
*GB/T 19666-2005 Flame retardant and fire resistant wires and cables
Code of China
Standard
GB/T 18380.2-2001  Tests on electric cables under fire conditions-Part 2:Test on a single small vertical insulated copper wire or cable (English Version)
Standard No.GB/T 18380.2-2001
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count1500 words
Price(USD)184.0
Implemented on2001-12-1
Deliveryvia email in 1~3 business day
Detail of GB/T 18380.2-2001
Standard No.
GB/T 18380.2-2001
English Name
Tests on electric cables under fire conditions-Part 2:Test on a single small vertical insulated copper wire or cable
Chinese Name
电缆在火焰条件下的燃烧试验 第2部分:单根铜心绝缘细电线或电缆垂直燃烧试验方法
Chinese Classification
K13
Professional Classification
GB
ICS Classification
Issued by
AQSIQ
Issued on
2001-07-12
Implemented on
2001-12-1
Status
superseded
Superseded by
GB/T 18380.21-2008 Tests on electric and optical fibre cables under fire conditions - Part 21: Test for vertical flame propagation for a single small insulated wire or cable - Apparatus
Superseded on
2009-4-1
Abolished on
2009-04-01
Superseding
GB 12666.2-1990
Language
English
File Format
PDF
Word Count
1500 words
Price(USD)
184.0
Keywords
GB/T 18380.2-2001, GB 18380.2-2001, GBT 18380.2-2001, GB/T18380.2-2001, GB/T 18380.2, GB/T18380.2, GB18380.2-2001, GB 18380.2, GB18380.2, GBT18380.2-2001, GBT 18380.2, GBT18380.2
Introduction of GB/T 18380.2-2001
Tests on Electric Cables under Fire Conditions — Part 2: Test on a Single Small Vertical Insulated Copper Wire or Cable 1 Scope This standard specifies a method of testing a small insulated wire under_ fire conditions when the method specified in GB/T 18380.1 is not suitable because some small conductors may melt during the application of the flame. The range of application. recommended is for solid copper conductors from 0.4 mm to 0.8 mm diameter and for stranded conductors from 0.1 mm2 to 0.5 mm2. cross-section. This standard includes the requirement for compliance. Note: The use of insulated wire which complies with this standard is not sufficient to prevent flame propagation under all conditions of installation. When the risk of propagation is high, such as with long. vertical runs of bunches of wires, it cannot be assumed that because a sample complies with this standard the bunch will behave in a similar manner. 2 Performance Requirement The test is intended for type approval testing or may be referred to in cable standards. One sample of insulated wire or cable, after having. been tested in accordance with Clauses 6, 7 and 8, shall comply with the following requirement: After all burning has ceased, the surface of the sample shall be wiped clean and the charred portion shall not have reached within 50 mm of the lower edge of the top clamp. 3 Test Equipment a) Propane burner complying with the requirements of Figure 1. It is allowable to fit an adaptor to burners not exactly complying with the figure in order to obtain the 8 mm bore shown. b) Propane bottle with pressure device and pressure gauge. c) Metal screen (1200 ± 25) mm high; (300 ± 25) mm wide and (450 ± 25) mm deep, with open front and closed top and bottom (see Figure 3). d) Stop watch. e) Electrically heated oven. 4 Sample
Contents of GB/T 18380.2-2001
1 Scope 2 Performance Requirement 3 Test Equipment 4 Sample 5 Conditioning Before Test 6 Test Conditions 7 Source of Heat 8 Test Procedure
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 18380.2-2001, GB 18380.2-2001, GBT 18380.2-2001, GB/T18380.2-2001, GB/T 18380.2, GB/T18380.2, GB18380.2-2001, GB 18380.2, GB18380.2, GBT18380.2-2001, GBT 18380.2, GBT18380.2