2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 18890.3-2015
GB/T 18890.3-2015   Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(Um=252 kV)―Part 3:Accessories (English Version)
Standard No.: GB/T 18890.3-2015 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 10500 words Translation Price(USD):260.0 remind me the price change

Email:

Implemented on:2016-5-1 Delivery: via email in 1 business day

→ → →

,,2016-5-1,E008A3ECE7AFAEBB1452150259165
Standard No.: GB/T 18890.3-2015
English Name: Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(Um=252 kV)―Part 3:Accessories
Chinese Name: 额定电压220kV(Um=252kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:电缆附件
Chinese Classification: K13    Cable and its accessory
Professional Classification: GB    National Standard
ICS Classification: 29.060.20 29.060.20    Cables 29.060.20
Source Content Issued by: AQSIQ; MOH
Issued on: 2015-10-09
Implemented on: 2016-5-1
Status: valid
Superseding:GB/Z 18890.3-2002 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220kV(Um=252kV) - Part 3: Accessories for power cables with cross-linked polyethylen
Target Language: English
File Format: PDF
Word Count: 10500 words
Translation Price(USD): 260.0
Delivery: via email in 1 business day
1 Scope This part of GB/T 18890 specifies the basic structure, model designation, technical requirements, test and acceptance rules, packaging, transportation and storage of power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220kV (Um=252kV). This part is applicable to outdoor termination, gas-immersed termination for GIS, oil-immersed (transformer) termination, straight joint and sectionalizing joint used for power cables with cross-linked polyethylene insulation for rated voltage of 220kV (Um=252kV) specified in GB/T 18890.1-2015 under ordinary installation conditions. This part is not applicable to insulated joint, transition joint for connecting cross-linked polyethylene insulated cable and paper insulated cable and separable cable termination. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 311.1-2012 Insulation Co-ordination - Part 1: Definitions, Principles and Rules GB/T 1527-2006 Drawn Tube of Copper and Copper Alloys GB/T 2900.10-2013 Electrotechnical Vocabulary - Electric Cables GB/T 3048.8-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 8: AC Voltage Test GB/T 3048.12-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 12: Partial Discharge Test GB/T 3048.13-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 13: Impulse Voltage Test GB/T 4109-2008 Insulated Insulator for Alternating Voltages above 1000V GB/T 4423-2007 Copper and Copper-alloy Cold-drawn Rod and Bar GB/T 7354-2003 Partial Discharge Measurements GB/T 8287.1-2008 Indoor and Outdoor Post Insulators for Systems with Nominal Voltage Greater than 1000V - Part 1: Test on Insulators of Ceramic Material or Glass GB/T 12464 Wooden Boxes GB/T 16927.1 High-voltage Test Techniques - Part 1: General Definitions and Test Requirements GB/T 18890.1-2015 Power Cables with Cross-linked Polyethylene Insulation and Their Accessories for Rated Voltage of 220kV (Um=252kV) - Part 1: Test Methods and Requirements GB/T 18890.2-2015 Power Cables with Cross-linked Polyethylene Insulation and Their Accessories for Rated Voltage of 220kV (Um=252kV) - Part 2: Power Cables GB/T 21429-2008 Composite Insulators - Hollow Insulators for Use in Outdoor and Indoor Electrical Equipment - Definitions, Test Methods, Acceptance Criteria and Design Recommendations GB/T 22381-2008 Cable Connections for Gas-insulated Metal-enclosed Switchgear for Rated Voltages of 72.5kV and Above - Fluid-filled and Extruded Insulation Power Cables - Fluid-filled and Dry Type Cable Terminations GB/T 23752-2009 Hollow Pressurized and Unpressurized Ceramic and Glass Insulators for Use in Electrical Equipment with Rated Voltages Greater than 1000V GB/T 26218.1-2010 Selection and Dimensioning of High-voltage Insulators Intended for Use in Polluted Conditions - Part 1: Definitions, Information and General Principles IEC 62271-209:2007 High-voltage Switchgear and Controlgear - Part 209: Cable Connections for Gas-insulated Metal-enclosed Switchgear for Rated Voltages above 52kV - Fluid-filled and Extruded Insulation Cables Fluid - Filled and Dry-type Cable Terminations IEC/TR 62271-301:2009 High-voltage Switchgear and Controlgear - Part 301: Dimensional Standardization of High-voltage Terminals 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 18890.1-2015 and GB/T 2900.10-2013 apply. For the convenience of application, some terms and definitions specified in GB/T 2900.10-2013 are listed below. 3.1 outdoor termination cable termination used by being directly exposed in sun and/or climatic environment [GB/T 2900.10-2013, definition 461-10-14] 3.2
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Service Conditions 5 Product Designation 6 Technical Requirements 7 Accessory Mark 8 Test and Requirement 9 Acceptance Rules 10 Packaging, Transportation and Storage Annex A (Informative) Performance of Semi-conductive Rubber Belt Annex B (Informative) Performance of Epoxy Resin Solidified Body (Adhesive) Annex C (Informative) Performance of Fluid Insulating Filler Annex D (Informative) Installation Guide Bibliography
Referred in GB/T 18890.3-2015:
*GB 311.1-2012 Insulation co-ordination - Part 1:Definitions, principles and rules
*GB/T 1527-2006 Drawn tube of copper and copper alloys
*GB/T 2900.10-2013 Electrotechnical Terminology - Electric Cables
*GB/T 3048.8-2007 Test methods for electrical properties of electric cables and wires—Part 8:AC voltage test
*GB/T 3048.12-2007 Test methods for electrical properties of electric cables and wires—Part 12:Partial discharge test
*GB/T 3048.13-2007 Test methods for electrical properties of electric cables and wires—Part 13: Impulse voltage test
*GB/T 4109-2008 Insulated bushings for alternating voltages above 1 000V
*GB/T 4423-2007 Copper and copper-alloy cold-drawn rod and bar
*GB/T 7354-2003 Partial discharge measurements
*GB/T 8287.1-2008 Indoor and outdoor post insulators for systems with nominal voltage greater than 1000 V - Part 1: Test on insulators of ceramic material or glass
*GB/T 12464-2016 Wooden boxes
*GB/T 16927.1-2011 High-voltage test techniques—Part 1:General definitions and test requirements
*GB/T 18890.1-2015 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(Um=252 kV)―Part 1:Test methods and requirements
*GB/T 18890.2-2015 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(Um=252 kV)―Part 2:Power cables
*GB/T 21429-2008 Composite insulators - Hollow insulators for use in outdoor and indoor electrical equipment - Definitions test methods acceptance criteria and design recommendations
*GB/T 22381-2008 Cable connections for gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above - Fluid-filled and extruded insulation power cables - Fluid-filled and dry type cable-terminations
*GB/T 23752-2009 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
*GB/T 26218.1-2010 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions—Part 1:Definitions,information and general principles
Code of China
Standard
GB/T 18890.3-2015  Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(Um=252 kV)―Part 3:Accessories (English Version)
Standard No.GB/T 18890.3-2015
Statusvalid
LanguageEnglish
File FormatPDF
Word Count10500 words
Price(USD)260.0
Implemented on2016-5-1
Deliveryvia email in 1 business day
Detail of GB/T 18890.3-2015
Standard No.
GB/T 18890.3-2015
English Name
Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(Um=252 kV)―Part 3:Accessories
Chinese Name
额定电压220kV(Um=252kV)交联聚乙烯绝缘电力电缆及其附件 第3部分:电缆附件
Chinese Classification
K13
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; MOH
Issued on
2015-10-09
Implemented on
2016-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/Z 18890.3-2002 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220kV(Um=252kV) - Part 3: Accessories for power cables with cross-linked polyethylen
Language
English
File Format
PDF
Word Count
10500 words
Price(USD)
260.0
Keywords
GB/T 18890.3-2015, GB 18890.3-2015, GBT 18890.3-2015, GB/T18890.3-2015, GB/T 18890.3, GB/T18890.3, GB18890.3-2015, GB 18890.3, GB18890.3, GBT18890.3-2015, GBT 18890.3, GBT18890.3
Introduction of GB/T 18890.3-2015
1 Scope This part of GB/T 18890 specifies the basic structure, model designation, technical requirements, test and acceptance rules, packaging, transportation and storage of power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220kV (Um=252kV). This part is applicable to outdoor termination, gas-immersed termination for GIS, oil-immersed (transformer) termination, straight joint and sectionalizing joint used for power cables with cross-linked polyethylene insulation for rated voltage of 220kV (Um=252kV) specified in GB/T 18890.1-2015 under ordinary installation conditions. This part is not applicable to insulated joint, transition joint for connecting cross-linked polyethylene insulated cable and paper insulated cable and separable cable termination. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 311.1-2012 Insulation Co-ordination - Part 1: Definitions, Principles and Rules GB/T 1527-2006 Drawn Tube of Copper and Copper Alloys GB/T 2900.10-2013 Electrotechnical Vocabulary - Electric Cables GB/T 3048.8-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 8: AC Voltage Test GB/T 3048.12-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 12: Partial Discharge Test GB/T 3048.13-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 13: Impulse Voltage Test GB/T 4109-2008 Insulated Insulator for Alternating Voltages above 1000V GB/T 4423-2007 Copper and Copper-alloy Cold-drawn Rod and Bar GB/T 7354-2003 Partial Discharge Measurements GB/T 8287.1-2008 Indoor and Outdoor Post Insulators for Systems with Nominal Voltage Greater than 1000V - Part 1: Test on Insulators of Ceramic Material or Glass GB/T 12464 Wooden Boxes GB/T 16927.1 High-voltage Test Techniques - Part 1: General Definitions and Test Requirements GB/T 18890.1-2015 Power Cables with Cross-linked Polyethylene Insulation and Their Accessories for Rated Voltage of 220kV (Um=252kV) - Part 1: Test Methods and Requirements GB/T 18890.2-2015 Power Cables with Cross-linked Polyethylene Insulation and Their Accessories for Rated Voltage of 220kV (Um=252kV) - Part 2: Power Cables GB/T 21429-2008 Composite Insulators - Hollow Insulators for Use in Outdoor and Indoor Electrical Equipment - Definitions, Test Methods, Acceptance Criteria and Design Recommendations GB/T 22381-2008 Cable Connections for Gas-insulated Metal-enclosed Switchgear for Rated Voltages of 72.5kV and Above - Fluid-filled and Extruded Insulation Power Cables - Fluid-filled and Dry Type Cable Terminations GB/T 23752-2009 Hollow Pressurized and Unpressurized Ceramic and Glass Insulators for Use in Electrical Equipment with Rated Voltages Greater than 1000V GB/T 26218.1-2010 Selection and Dimensioning of High-voltage Insulators Intended for Use in Polluted Conditions - Part 1: Definitions, Information and General Principles IEC 62271-209:2007 High-voltage Switchgear and Controlgear - Part 209: Cable Connections for Gas-insulated Metal-enclosed Switchgear for Rated Voltages above 52kV - Fluid-filled and Extruded Insulation Cables Fluid - Filled and Dry-type Cable Terminations IEC/TR 62271-301:2009 High-voltage Switchgear and Controlgear - Part 301: Dimensional Standardization of High-voltage Terminals 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 18890.1-2015 and GB/T 2900.10-2013 apply. For the convenience of application, some terms and definitions specified in GB/T 2900.10-2013 are listed below. 3.1 outdoor termination cable termination used by being directly exposed in sun and/or climatic environment [GB/T 2900.10-2013, definition 461-10-14] 3.2
Contents of GB/T 18890.3-2015
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Service Conditions 5 Product Designation 6 Technical Requirements 7 Accessory Mark 8 Test and Requirement 9 Acceptance Rules 10 Packaging, Transportation and Storage Annex A (Informative) Performance of Semi-conductive Rubber Belt Annex B (Informative) Performance of Epoxy Resin Solidified Body (Adhesive) Annex C (Informative) Performance of Fluid Insulating Filler Annex D (Informative) Installation Guide Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 18890.3-2015, GB 18890.3-2015, GBT 18890.3-2015, GB/T18890.3-2015, GB/T 18890.3, GB/T18890.3, GB18890.3-2015, GB 18890.3, GB18890.3, GBT18890.3-2015, GBT 18890.3, GBT18890.3