GB/T 19071.1-2018   Wind turbines—Asynchronous generator—Part 1:Technical conditions (English Version)
Standard No.: GB/T 19071.1-2018 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 7500 words Translation Price(USD):150.0 remind me the price change

Email:

Implemented on:2018-12-1 Delivery: via email in 1 business day

→ → →

,,2018-12-1,4963F805BE9A20861536203999470
Standard No.: GB/T 19071.1-2018
English Name: Wind turbines—Asynchronous generator—Part 1:Technical conditions
Chinese Name: 风力发电机组 异步发电机 第1部分:技术条件
Chinese Classification: F11    Wind energy
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2018-05-14
Implemented on: 2018-12-1
Status: valid
Superseding:GB/T 19071.1-2003 Asynchronous generator for wind turbine generator systems—Part 1:Technical condition
Target Language: English
File Format: PDF
Word Count: 7500 words
Translation Price(USD): 150.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. GB/T 19071 consists of two parts under the general title Wind turbines - Asynchronous generator: ——Part 1: Technical conditions; ——Part 2: Testing methods. This is part 1 of GB/T 19071. This part is developed in accordance with the rules given in GB/T 1.1-2009. This part replaces GB/T 19071.1-2003 Asynchronous generator for wind turbine generator systems - Part 1: Test conditions. The following main technical changes have been made with respect to GB/T 19071.1-2003: —— the application scope is modified (see Clause 1); —— the normative references GB/T 1971, GB/T 1032, GB/T 10069.3, and GB/T 20626.1 are added (see Clause 2); —— the rated power specifications for single-speed generators are added: 50 kW, 100 kW, 800 kW, 1,100 kW, 2,000 kW, 2,500 kW, and 3,000 kW (any special requirements by the users may be negotiated with the manufacturer) (see 3.5); —— the specifications of "400 V, 1,000V, 1,500V" are deleted for rated power of single-speed generator (see 3.6); —— the specifications of "660 kW/180 kW, 750 kW/220 kW" are deleted for rated power of double-speed generator; and the specifications of “660 kW/150 kW, 750 kW/200 kW, 1,300 kW/250 kW” are added (see 3.7); —— the synchronous speed of 1,000 r/min/750 r/min is added for double-speed generator (see 3.8); —— the slip ratios are deleted for single-speed and double-speed generators (see 3.9 of Edition 2003); —— the diameter specification and deviation are added for shaft extension without keyway (see 3.9, Table 1); —— the circular run-out tolerance is modified for the shaft extension (see 3.10 of this standard; and 3.10.3 of Edition 2003); —— the installation size is added for generators with center heights of 560 and 630 (see 3.11 of this standard; and 3.10.2 of Edition 2003); —— the minimum ambient air temperature is modified from not less than "-15 ℃" to "-20 ℃", and the requirements are canceled for ambient temperature in cold areas [see 4.2 b) of this standard; and 4.2.2 of Edition 2003]; —— the monthly average minimum temperature corresponding to relative humidity is deleted [see 4.2 c) of this standard; and 4.2.3 of Edition 2003]; —— the provision is added that "efficiency is determined by direct method"; the provision is changed that stray loss is calculated from “0.025 lgPn to 0.005 lgPn” instead of “0.5%” of rated output (see 4.4); —— the overspeed of generator is changed from “1.2 times rated speed” to “1.2 times maximum operating speed”, and contents is added that any special requirements for overspeed by users may be negotiated with the manufacturer (see 4.8); —— the requirement is added that when measuring resistance, the selection of tramegger shall meet the requirements of GB/T 1032 (see 4.9); —— the requirement is added that there shall be no damage between turns after the short-term voltage rising test (see 4.12); —— the requirement for vibration limits of generators during no-load motor operation is changed from “velocity RMS value shall not exceed 2.8 mm/s” to “according to Table 1 of GB/T 10068-2008”, and the determination and requirements are added for the vibration after overspeed test (see 4.14); —— the requirement for noise limits of generator is changed from “according to Table 5” to “according to the requirements of GB/T 10069.3” (see 4.15); —— the requirements is added that the current waveform distortion rate of the generator shall not be greater than 5% (see 4.17); —— the end-of-manufacturing test items are added such as the “phase sequence inspection of windings”, “locked rotor test at rated frequency”, and “hourly thermal test” (see 6.1.2 of this standard; and 6.2 of Edition 2003); —— the description is deleted for the specific inspection contents of appearance and mechanical inspection items of generator (see 6.5 of Edition 2003); —— the type test items are added such as “efficiency determination”, “rotational inertia test”, “determination of distortion rate of current waveform”, and “weighting” (see 6.2.2 of this standard; and 6.4 of Edition 2003); —— the type test item of the “enclosure protection grade test” is deleted (see 6.2.2 of this standard; and 6.4 of Edition 2003); —— the environmental and safety requirements are added (see Clause 8); —— the quality warranty period is added (see Clause 9). This part was proposed by the China Machinery Industry Federation. This part is under the jurisdiction of the National Technical Committee 50 on Wind Power Machinery of Standardization Administration of China. The previous edition replaced by this part is as follows: —— GB/T 19071.1-2003. Wind turbines - Asynchronous generator - Part 1: Technical conditions 1 Scope This part of GB/T 19071 specifies the main types, basic parameters and dimensions, technical requirements, test methods, inspection rules, inspection items, marking, packaging, transport and other requirements for asynchronous generators of grid-connected and fixed-speed wind turbines. This part is applicable to the single-speed or double-speed asynchronous generators (hereinafter referred to as "generators") of grid-connected and fixed-speed wind turbines, and may serve as a reference for other types of generators. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 191 Packaging - Pictorial marking for handling of goods GB/T 755 Rotating electrical machines - Rating and performance GB/T 997-2008 Rotating electrical machines - Classification of types of construction, mounting arrangements and terminal box position for (IM Code) GB/T 1032 Test procedures for three-phase induction motors GB/T 1971 Rotating electrical machines - Terminal markings and direction of rotation GB/T 4942.1-2006 Degrees of protection provided by the integral design of rotating electrical machined (IP code) - Classification GB/T 10068-2008 Mechanical vibration of certain machines with shaft heights 56 mm and higher - Measurement, evaluation and limits of vibration severity GB/T 10069.1 Measurement of airborne noise emitted by rotating electrical machines and the noise limits - Part 1: Method for the measurement of airborne noise emitted by rotating electrical machines GB/T 10069.3 Measurement of airborne noise emitted by rotating electrical machines and the noise limits - Part 3: Noise limits GB/T 12665 Requirements of damp-heat testing of electrical machine for service in general environmental condition GB/T 19071.2 Wind turbines - Asynchronous generator - Part 2: Testing methods GB/T 22714 Test specifications of interturn insulation of form-wound winding for AC low-voltage electrical machines GB/T 22719.1 Interturn insulation of random-wound winding for AC low-voltage electrical machines - Part 1: Test methods GB/T 22719.2 Interturn insulation of random-wound winding for AC low-voltage electrical machines - Part 2: Test limits 3 Types, basic parameters, and dimensions 3.1 The protection grade of generator enclosure shall not be inferior to the requirements of IP 44 in GB/T 4942.1-2006. 3.2 The generator shall have a reliable cooling method. If ventilation cooling method is adopted, it shall be ensured that the introduced air shall not cause harm to the generator. If water cooling method is adopted, there shall be no water seepage and leakage problems. 3.3 The structure and installation type of the generator shall meet the requirements of IM B3 in GB/T 997-2008. 3.4 The generator quota is a continuous quota based on the continuous working system (S1). 3.5 Single-speed generators are recommended to be manufactured at the following rated power: 50 kW, 100 kW, 150 kW, 200 kW, 250 kW, 300 kW, 400 kW, 500 kW, 600 kW, 660 kW, 750 kW, 800 kW, 1,000 kW, 1,100 kW, 1,320 kW, 1,500 kW, 2,000 kW, 2,500 kW, and 3,000 kW (any special requirements by users may be negotiated with the manufacturer). 3.6 The rated frequency of the single-speed generator is 50 Hz, the synchronous speed is 1,500 r/min, and the rated voltage is 690 V (any special requirements by users may be negotiated with the manufacturer). 3.7 The double-speed generator shall be manufactured at the following rated power: 600 kW/125 kW, 660 kW/150 kW, 750 kW/200 kW, and 1,300 kW/250 kW (any special requirements by users may be negotiated with the manufacturer). 3.8 The rated frequency of the double-speed generator is 50 Hz, the synchronous speed is 1,500 r/min/1,000 r/min, 1,000r/min/750r/min, and the rated voltage is 690V/690V (any special requirements by users may be negotiated with the manufacturer). Note: For the double-speed generator power, voltage, speed, slip ratio and other parameters, the expression method is as follows: the parameters before the slash correspond to the high speed state, and the parameters after the slash correspond to the low speed state. 3.9 The dimension and deviation of generator shaft extension (without keyway) shall meet the requirements in Table 1, and the dimension and deviation of generator shaft extension key (with keyway) shall meet the requirements in Table 2 (any special requirements by users may be negotiated with the manufacturer). Table 1 The dimension and deviation of shaft extension (without keyway) Shaft extension diameter mm Deviation mm 90 0, -0.022 100 0, -0.022 110 0, -0.022 130 0, -0.025 150 0, -0.025 170 0, -0.025 Table 2 The dimension and deviation of shaft extension key (with keyway) Shaft extension diameter mm Key width mm Key height mm 90 100 110 130 170 3.10 The shaft extension radial circular runout tolerance shall meet the requirements in Table 3. Table 3 The shaft extension radial circular runout tolerance Shaft extension diameter mm Circular runout tolerance mm >80~120 0.05 >130 0.06 3.11 The mounting dimension and overall dimension of the generator shall meet the requirements specified in Table 4 and Figure 1 (any special requirements by users may be negotiated with the manufacturer). Table 4 Frame with footing, mounting type IM B3 Center height Mounting dimension and tolerance/ mm Overall dimension limit/ mm A B C D E F G H K AB AC AD HD L Basic dimension Basic dimension Basic dimension Limit deviation Basic dimension Limit deviation Basic dimension Limit deviation Basic dimension Limit deviation Basic dimension Limit deviation Basic dimension Limit deviation Basic dimension Limit deviation 315 508 508 216 ±4.0 90 +0.035 +0.013 170 ±0.57 25 0 -0.052 81 0 -0.2 315 0 -1.0 28 +0.52 0 750 650 580 870 1,340 355 610 630 254 100 210 28 90 355 740 750 680 1,035 1,540 450 800 1,120 355 110 450 35 900 900 760 1,140 2,050 500 900 1,250 475 130 +0.04 0.015 250 32 0 -0.062 119 500 42 +0.62 0 1,050 1,050 970 1,200 2,550 560 1,000 1,400 500 130 250 560 42 1,200 1,200 1,100 1,300 3,020 630 1,120 1,600 530 170 300 ±0.65 40 157 0 -0.3 630 48 1,300 1,300 1,150 1,500 3,100 Note: The limit deviation of the basic dimension D and the basic dimension F are the dimension and deviation of the shaft extension with keyway. Figure 1 3.12 The parallelism tolerance of the generator axis to the footing supporting surface is 1 mm. 3.13 the flatness tolerance of the generator footing supporting surface is 0.30 mm. 3.14 If the generator shaft extension is equipped with keyway, its symmetry tolerance is 0.05 mm. The coaxiality tolerance of parallel shaft extension is 0.05 mm. 4 Technical requirements 4.1.1 The generator shall meet the requirements of this part, and be fabricated according to the drawings and technical documents approved through established procedures. 4.2 The generator shall be able to operate normally under the following altitude, ambient temperature and relative humidity conditions: a) the altitude does not exceed 1,000 m; b) the ambient air temperature is not higher than 40 ℃ and not lower than -20 ℃; c) the average maximum air relative humidity in the wettest month is not greater than 95%. If the generator needs to operate under conditions exceeding one or more of the above limits, its special requirements may be negotiated between the user and the manufacturer. 4.3 At rated speed and rated power factor, the generator shall be able to operate normally when the deviation between voltage, frequency and rated value meets the requirements of GB/T 755. 4.4 If the generator is in rated operation, the tolerance of the output rated efficiency and power factor shall meet the requirements of Table 5. The efficiency is measured by direct method or indirect method, and the stray loss is calculated according to the (0.025 lgPn to 0.005 lgPn) of rated output.
Foreword i 1 Scope 2 Normative references 3 Types, basic parameters, and dimensions 4 Technical requirements 5 Test methods 6 Inspection rules 7 Marking, packaging, transport and storage 8 Environmental and safety requirements 9 Quality warranty period
Referred in GB/T 19071.1-2018:
*GB/T 191-2008 Packaging - Pictorial Marking for Handling of Goods
*GB/T 755-2019 Rotating electrical machines—Rating and performance
*GB/T 997-2008 Rotating Electrical Machines—Classification of Types of Construction, Mounting Arrangements and Terminal Box Position (IM Code)
*GB/T 1032-2012 Test procedures for three-phase induction motors
*GB/T 1971-2021 Rotating electrical machines—Terminal markings and direction of rotation
*GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machined (IP Code)-Classification
*GBT10068-2008
*GB/T 10069.1-2006 Measurement of airborne noise emitted by rotating electrical machines and the noise limits Part 1: Method for the measurement of airborne noise emitted by rotating electrical machines
*GBT10069.3-
*GB/T 12665-2017 Requirements of damp-heat testing of electrical machine for service in general environmental condition
*GB/T 19071.2-2018 Wind turbines—Asynchronous generatorg—Part 2:Testing methods
*GB/T 22714-2008 Test specifications of interturn insulation of form-wound winding for AC low-voltage electrical machines
*GB/T 22719.1-2008 Interturn insulation of random-wound winding for AC low-voltage electrical machines - Part 1: Test methods
*GB/T 22719.2-2008 Interturn insulation of random-wound winding for AC low-voltage electrical machines - Part 2: Test limits
Code of China
Standard
GB/T 19071.1-2018  Wind turbines—Asynchronous generator—Part 1:Technical conditions (English Version)
Standard No.GB/T 19071.1-2018
Statusvalid
LanguageEnglish
File FormatPDF
Word Count7500 words
Price(USD)150.0
Implemented on2018-12-1
Deliveryvia email in 1 business day
Detail of GB/T 19071.1-2018
Standard No.
GB/T 19071.1-2018
English Name
Wind turbines—Asynchronous generator—Part 1:Technical conditions
Chinese Name
风力发电机组 异步发电机 第1部分:技术条件
Chinese Classification
F11
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2018-05-14
Implemented on
2018-12-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 19071.1-2003 Asynchronous generator for wind turbine generator systems—Part 1:Technical condition
Language
English
File Format
PDF
Word Count
7500 words
Price(USD)
150.0
Keywords
GB/T 19071.1-2018, GB 19071.1-2018, GBT 19071.1-2018, GB/T19071.1-2018, GB/T 19071.1, GB/T19071.1, GB19071.1-2018, GB 19071.1, GB19071.1, GBT19071.1-2018, GBT 19071.1, GBT19071.1
Introduction of GB/T 19071.1-2018
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. GB/T 19071 consists of two parts under the general title Wind turbines - Asynchronous generator: ——Part 1: Technical conditions; ——Part 2: Testing methods. This is part 1 of GB/T 19071. This part is developed in accordance with the rules given in GB/T 1.1-2009. This part replaces GB/T 19071.1-2003 Asynchronous generator for wind turbine generator systems - Part 1: Test conditions. The following main technical changes have been made with respect to GB/T 19071.1-2003: —— the application scope is modified (see Clause 1); —— the normative references GB/T 1971, GB/T 1032, GB/T 10069.3, and GB/T 20626.1 are added (see Clause 2); —— the rated power specifications for single-speed generators are added: 50 kW, 100 kW, 800 kW, 1,100 kW, 2,000 kW, 2,500 kW, and 3,000 kW (any special requirements by the users may be negotiated with the manufacturer) (see 3.5); —— the specifications of "400 V, 1,000V, 1,500V" are deleted for rated power of single-speed generator (see 3.6); —— the specifications of "660 kW/180 kW, 750 kW/220 kW" are deleted for rated power of double-speed generator; and the specifications of “660 kW/150 kW, 750 kW/200 kW, 1,300 kW/250 kW” are added (see 3.7); —— the synchronous speed of 1,000 r/min/750 r/min is added for double-speed generator (see 3.8); —— the slip ratios are deleted for single-speed and double-speed generators (see 3.9 of Edition 2003); —— the diameter specification and deviation are added for shaft extension without keyway (see 3.9, Table 1); —— the circular run-out tolerance is modified for the shaft extension (see 3.10 of this standard; and 3.10.3 of Edition 2003); —— the installation size is added for generators with center heights of 560 and 630 (see 3.11 of this standard; and 3.10.2 of Edition 2003); —— the minimum ambient air temperature is modified from not less than "-15 ℃" to "-20 ℃", and the requirements are canceled for ambient temperature in cold areas [see 4.2 b) of this standard; and 4.2.2 of Edition 2003]; —— the monthly average minimum temperature corresponding to relative humidity is deleted [see 4.2 c) of this standard; and 4.2.3 of Edition 2003]; —— the provision is added that "efficiency is determined by direct method"; the provision is changed that stray loss is calculated from “0.025 lgPn to 0.005 lgPn” instead of “0.5%” of rated output (see 4.4); —— the overspeed of generator is changed from “1.2 times rated speed” to “1.2 times maximum operating speed”, and contents is added that any special requirements for overspeed by users may be negotiated with the manufacturer (see 4.8); —— the requirement is added that when measuring resistance, the selection of tramegger shall meet the requirements of GB/T 1032 (see 4.9); —— the requirement is added that there shall be no damage between turns after the short-term voltage rising test (see 4.12); —— the requirement for vibration limits of generators during no-load motor operation is changed from “velocity RMS value shall not exceed 2.8 mm/s” to “according to Table 1 of GB/T 10068-2008”, and the determination and requirements are added for the vibration after overspeed test (see 4.14); —— the requirement for noise limits of generator is changed from “according to Table 5” to “according to the requirements of GB/T 10069.3” (see 4.15); —— the requirements is added that the current waveform distortion rate of the generator shall not be greater than 5% (see 4.17); —— the end-of-manufacturing test items are added such as the “phase sequence inspection of windings”, “locked rotor test at rated frequency”, and “hourly thermal test” (see 6.1.2 of this standard; and 6.2 of Edition 2003); —— the description is deleted for the specific inspection contents of appearance and mechanical inspection items of generator (see 6.5 of Edition 2003); —— the type test items are added such as “efficiency determination”, “rotational inertia test”, “determination of distortion rate of current waveform”, and “weighting” (see 6.2.2 of this standard; and 6.4 of Edition 2003); —— the type test item of the “enclosure protection grade test” is deleted (see 6.2.2 of this standard; and 6.4 of Edition 2003); —— the environmental and safety requirements are added (see Clause 8); —— the quality warranty period is added (see Clause 9). This part was proposed by the China Machinery Industry Federation. This part is under the jurisdiction of the National Technical Committee 50 on Wind Power Machinery of Standardization Administration of China. The previous edition replaced by this part is as follows: —— GB/T 19071.1-2003. Wind turbines - Asynchronous generator - Part 1: Technical conditions 1 Scope This part of GB/T 19071 specifies the main types, basic parameters and dimensions, technical requirements, test methods, inspection rules, inspection items, marking, packaging, transport and other requirements for asynchronous generators of grid-connected and fixed-speed wind turbines. This part is applicable to the single-speed or double-speed asynchronous generators (hereinafter referred to as "generators") of grid-connected and fixed-speed wind turbines, and may serve as a reference for other types of generators. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 191 Packaging - Pictorial marking for handling of goods GB/T 755 Rotating electrical machines - Rating and performance GB/T 997-2008 Rotating electrical machines - Classification of types of construction, mounting arrangements and terminal box position for (IM Code) GB/T 1032 Test procedures for three-phase induction motors GB/T 1971 Rotating electrical machines - Terminal markings and direction of rotation GB/T 4942.1-2006 Degrees of protection provided by the integral design of rotating electrical machined (IP code) - Classification GB/T 10068-2008 Mechanical vibration of certain machines with shaft heights 56 mm and higher - Measurement, evaluation and limits of vibration severity GB/T 10069.1 Measurement of airborne noise emitted by rotating electrical machines and the noise limits - Part 1: Method for the measurement of airborne noise emitted by rotating electrical machines GB/T 10069.3 Measurement of airborne noise emitted by rotating electrical machines and the noise limits - Part 3: Noise limits GB/T 12665 Requirements of damp-heat testing of electrical machine for service in general environmental condition GB/T 19071.2 Wind turbines - Asynchronous generator - Part 2: Testing methods GB/T 22714 Test specifications of interturn insulation of form-wound winding for AC low-voltage electrical machines GB/T 22719.1 Interturn insulation of random-wound winding for AC low-voltage electrical machines - Part 1: Test methods GB/T 22719.2 Interturn insulation of random-wound winding for AC low-voltage electrical machines - Part 2: Test limits 3 Types, basic parameters, and dimensions 3.1 The protection grade of generator enclosure shall not be inferior to the requirements of IP 44 in GB/T 4942.1-2006. 3.2 The generator shall have a reliable cooling method. If ventilation cooling method is adopted, it shall be ensured that the introduced air shall not cause harm to the generator. If water cooling method is adopted, there shall be no water seepage and leakage problems. 3.3 The structure and installation type of the generator shall meet the requirements of IM B3 in GB/T 997-2008. 3.4 The generator quota is a continuous quota based on the continuous working system (S1). 3.5 Single-speed generators are recommended to be manufactured at the following rated power: 50 kW, 100 kW, 150 kW, 200 kW, 250 kW, 300 kW, 400 kW, 500 kW, 600 kW, 660 kW, 750 kW, 800 kW, 1,000 kW, 1,100 kW, 1,320 kW, 1,500 kW, 2,000 kW, 2,500 kW, and 3,000 kW (any special requirements by users may be negotiated with the manufacturer). 3.6 The rated frequency of the single-speed generator is 50 Hz, the synchronous speed is 1,500 r/min, and the rated voltage is 690 V (any special requirements by users may be negotiated with the manufacturer). 3.7 The double-speed generator shall be manufactured at the following rated power: 600 kW/125 kW, 660 kW/150 kW, 750 kW/200 kW, and 1,300 kW/250 kW (any special requirements by users may be negotiated with the manufacturer). 3.8 The rated frequency of the double-speed generator is 50 Hz, the synchronous speed is 1,500 r/min/1,000 r/min, 1,000r/min/750r/min, and the rated voltage is 690V/690V (any special requirements by users may be negotiated with the manufacturer). Note: For the double-speed generator power, voltage, speed, slip ratio and other parameters, the expression method is as follows: the parameters before the slash correspond to the high speed state, and the parameters after the slash correspond to the low speed state. 3.9 The dimension and deviation of generator shaft extension (without keyway) shall meet the requirements in Table 1, and the dimension and deviation of generator shaft extension key (with keyway) shall meet the requirements in Table 2 (any special requirements by users may be negotiated with the manufacturer). Table 1 The dimension and deviation of shaft extension (without keyway) Shaft extension diameter mm Deviation mm 90 0, -0.022 100 0, -0.022 110 0, -0.022 130 0, -0.025 150 0, -0.025 170 0, -0.025 Table 2 The dimension and deviation of shaft extension key (with keyway) Shaft extension diameter mm Key width mm Key height mm 90 100 110 130 170 3.10 The shaft extension radial circular runout tolerance shall meet the requirements in Table 3. Table 3 The shaft extension radial circular runout tolerance Shaft extension diameter mm Circular runout tolerance mm >80~120 0.05 >130 0.06 3.11 The mounting dimension and overall dimension of the generator shall meet the requirements specified in Table 4 and Figure 1 (any special requirements by users may be negotiated with the manufacturer). Table 4 Frame with footing, mounting type IM B3 Center height Mounting dimension and tolerance/ mm Overall dimension limit/ mm A B C D E F G H K AB AC AD HD L Basic dimension Basic dimension Basic dimension Limit deviation Basic dimension Limit deviation Basic dimension Limit deviation Basic dimension Limit deviation Basic dimension Limit deviation Basic dimension Limit deviation Basic dimension Limit deviation 315 508 508 216 ±4.0 90 +0.035 +0.013 170 ±0.57 25 0 -0.052 81 0 -0.2 315 0 -1.0 28 +0.52 0 750 650 580 870 1,340 355 610 630 254 100 210 28 90 355 740 750 680 1,035 1,540 450 800 1,120 355 110 450 35 900 900 760 1,140 2,050 500 900 1,250 475 130 +0.04 0.015 250 32 0 -0.062 119 500 42 +0.62 0 1,050 1,050 970 1,200 2,550 560 1,000 1,400 500 130 250 560 42 1,200 1,200 1,100 1,300 3,020 630 1,120 1,600 530 170 300 ±0.65 40 157 0 -0.3 630 48 1,300 1,300 1,150 1,500 3,100 Note: The limit deviation of the basic dimension D and the basic dimension F are the dimension and deviation of the shaft extension with keyway. Figure 1 3.12 The parallelism tolerance of the generator axis to the footing supporting surface is 1 mm. 3.13 the flatness tolerance of the generator footing supporting surface is 0.30 mm. 3.14 If the generator shaft extension is equipped with keyway, its symmetry tolerance is 0.05 mm. The coaxiality tolerance of parallel shaft extension is 0.05 mm. 4 Technical requirements 4.1.1 The generator shall meet the requirements of this part, and be fabricated according to the drawings and technical documents approved through established procedures. 4.2 The generator shall be able to operate normally under the following altitude, ambient temperature and relative humidity conditions: a) the altitude does not exceed 1,000 m; b) the ambient air temperature is not higher than 40 ℃ and not lower than -20 ℃; c) the average maximum air relative humidity in the wettest month is not greater than 95%. If the generator needs to operate under conditions exceeding one or more of the above limits, its special requirements may be negotiated between the user and the manufacturer. 4.3 At rated speed and rated power factor, the generator shall be able to operate normally when the deviation between voltage, frequency and rated value meets the requirements of GB/T 755. 4.4 If the generator is in rated operation, the tolerance of the output rated efficiency and power factor shall meet the requirements of Table 5. The efficiency is measured by direct method or indirect method, and the stray loss is calculated according to the (0.025 lgPn to 0.005 lgPn) of rated output.
Contents of GB/T 19071.1-2018
Foreword i 1 Scope 2 Normative references 3 Types, basic parameters, and dimensions 4 Technical requirements 5 Test methods 6 Inspection rules 7 Marking, packaging, transport and storage 8 Environmental and safety requirements 9 Quality warranty period