2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 23479.1-2009
GB/T 23479.1-2009   Wind turbine double-fed asynchronous generator - Part 1: Technical specification (English Version)
Standard No.: GB/T 23479.1-2009 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 6000 words Translation Price(USD):180.0 remind me the price change

Email:

Implemented on:2009-11-1 Delivery: via email in 1 business day

→ → →

,2023-12-1,2009-11-1,141138181866259D532741202DE97
Standard No.: GB/T 23479.1-2009
English Name: Wind turbine double-fed asynchronous generator - Part 1: Technical specification
Chinese Name: 风力发电机组 双馈异步发电机 第1部分:技术条件
Chinese Classification: F11    Wind energy
Professional Classification: GB    National Standard
Source Content Issued by: AQSIQ; SAC
Issued on: 2009-4-2
Implemented on: 2009-11-1
Status: superseded
Superseded by:GB/T 23479-2023 Wind turbine―Doubly-fed induction generator
Superseded on:2023-12-1
Target Language: English
File Format: PDF
Word Count: 6000 words
Translation Price(USD): 180.0
Delivery: via email in 1 business day
Wind turbine - Double-fed asynchronous generator - Part 1: Technical specification 1 Scope This part of GB/T 23479 specifies types, specifications, technical requirements, testing methods, inspection rules, safety and warning signs, product information, packaging, transport and storage of low-voltage double-fed asynchronous generators for grid-connected wind turbines. This part of GB/T 23479 is applicable to low-voltage double-fed asynchronous generators for grid-connected wind turbines (hereinafter referred to as generators). 2 Normative references The following documents contain provisions which, through reference in this part of GB/T 23479, constitute provisions of this part. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this part. However parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document applies. GB 755 Rotating electrical machines - Rating and performance (GB 755-2000, idt IEC 60034-1: 1996) GB/T 997 Rotating electrical machines - Classification of types of construction, mounting arrangements and terminal box position for (IM Code) (GB/T 997-2008, IEC 60034-7: 2001, IDT) GB/T 1032 Test procedures for three-phase induction motors GB 1971 Rotating electrical machines - Terminal markings and direction of rotation (GB 1971-2006, IEC 60034-8: 2002, IDT) GB/T 1993 Cooling methods for rotating electrical machines (GB/T 1993-1993, idt IEC 60034-6: 1991) GB/T 2900.25 Electrotechnical terminology - Rotating electrical machines (GB/T 2900.25-2008, IEC 60050-411: 1996, IDT) GB/T 4942.1-2006 Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification (IEC 60034-5: 2000, IDT) GB 10068 Mechanical vibration of certain machines with shaft heights 56 mm and higher - Measurement, evaluation and limits of vibration severity (GB 10068-2008, IEC 60034-14: 2007, IDT) GB 10069.3 Measurement of airborne noise emitted by rotating electrical machines and the noise limits - Part 3: Noise limits (GB 10069.3-2008, IEC 60034-9: 2007, IDT) GB/T 23479.2 Wind turbine - Double-fed asynchronous generator - Part 2: Testing methods JB/T 5811 Test method and limits of form-wound winding for alternating current low-voltage electrical machines JB/T 9615.2 Test limits of the interturn insulation on random wound winding for AC low-voltage machines 3 Terms and definitions For the purposes of this part, the terms and definitions given in GB/T 2900.25 and the following apply. 3.1 doubly-fed asynchronous generator variable speed constant frequency generator in which the stator and rotor are directly or indirectly connected to the power grid and capable of exchanging energy 3.2 operating speed range speed range, namely, nmin~nmax, within which the generator shall be able to operate reliably when the synchronous speed of the generator is taken as the basic speed value (n0), where nmin is the speed corresponding to the cut-in wind speed of the wind turbine (nminn0)
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Symbols and units 5 Model, type of construction, main parameter series and rating 6 Technical requirements 7 Testing method 8 Inspection rules 9 Sampling method and judgment rules 10 Safety and warning signs 11 Product information 12 Packaging, transport and storage
Referred in GB/T 23479.1-2009:
*GB 755-2008 Rotating Electrical Machines - Rating and Performance
*GB/T 997-2008 Rotating Electrical Machines—Classification of Types of Construction, Mounting Arrangements and Terminal Box Position (IM Code)
*GB/T 1032-2012 Test procedures for three-phase induction motors
*GB 1971-2006 Rotating Electrical Machines - Terminal Markings and Direction of Rotation
*GB/T 1993-1993 Cooling methods for rotating electrical machines
*GB/T 2900.25-2008 Electrotechnical terminology - Rotating electrical machines
*GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machined (IP Code)-Classification
*GB 10068-2008 Mechanical vibration of certain machines with shaft heights 56 mm and higher-measurement evaluation and limits of vibration severity
*GB 10069.3-2008 Measurement of Airborne Noise Emitted by Rotating Electrical Machines and the Noise Limits — Part 3: Noise Limits
*GB/T 23479.2-2009 Wind turbine double-fed asynchronous generator - Part 2: Testing methods
*JB/T 5811-2007 Test method and limits of form-wound winding for alternating current low-voltage electrical mechines
*JB/T 9615.2-2000 test limits of the interturn insulation on random wound winding for ac low-voltage machines
GB/T 23479.1-2009 is referred in:
* NB/T 31013-2011 Manufactural technical specification for double fed wind turbine generator
*GB/T 20319-2017 Wind turbine generator systems. Specification for acceptance
*GB/T 31140-2014 Environment specifications of wind-power generation equipments for plateau
Code of China
Standard
GB/T 23479.1-2009   Wind turbine double-fed asynchronous generator - Part 1: Technical specification (English Version)
Standard No.GB/T 23479.1-2009
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)180.0
Implemented on2009-11-1
Deliveryvia email in 1 business day
Detail of GB/T 23479.1-2009
Standard No.
GB/T 23479.1-2009
English Name
Wind turbine double-fed asynchronous generator - Part 1: Technical specification
Chinese Name
风力发电机组 双馈异步发电机 第1部分:技术条件
Chinese Classification
F11
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2009-4-2
Implemented on
2009-11-1
Status
superseded
Superseded by
GB/T 23479-2023 Wind turbine―Doubly-fed induction generator
Superseded on
2023-12-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
180.0
Keywords
GB/T 23479.1-2009, GB 23479.1-2009, GBT 23479.1-2009, GB/T23479.1-2009, GB/T 23479.1, GB/T23479.1, GB23479.1-2009, GB 23479.1, GB23479.1, GBT23479.1-2009, GBT 23479.1, GBT23479.1
Introduction of GB/T 23479.1-2009
Wind turbine - Double-fed asynchronous generator - Part 1: Technical specification 1 Scope This part of GB/T 23479 specifies types, specifications, technical requirements, testing methods, inspection rules, safety and warning signs, product information, packaging, transport and storage of low-voltage double-fed asynchronous generators for grid-connected wind turbines. This part of GB/T 23479 is applicable to low-voltage double-fed asynchronous generators for grid-connected wind turbines (hereinafter referred to as generators). 2 Normative references The following documents contain provisions which, through reference in this part of GB/T 23479, constitute provisions of this part. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this part. However parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document applies. GB 755 Rotating electrical machines - Rating and performance (GB 755-2000, idt IEC 60034-1: 1996) GB/T 997 Rotating electrical machines - Classification of types of construction, mounting arrangements and terminal box position for (IM Code) (GB/T 997-2008, IEC 60034-7: 2001, IDT) GB/T 1032 Test procedures for three-phase induction motors GB 1971 Rotating electrical machines - Terminal markings and direction of rotation (GB 1971-2006, IEC 60034-8: 2002, IDT) GB/T 1993 Cooling methods for rotating electrical machines (GB/T 1993-1993, idt IEC 60034-6: 1991) GB/T 2900.25 Electrotechnical terminology - Rotating electrical machines (GB/T 2900.25-2008, IEC 60050-411: 1996, IDT) GB/T 4942.1-2006 Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification (IEC 60034-5: 2000, IDT) GB 10068 Mechanical vibration of certain machines with shaft heights 56 mm and higher - Measurement, evaluation and limits of vibration severity (GB 10068-2008, IEC 60034-14: 2007, IDT) GB 10069.3 Measurement of airborne noise emitted by rotating electrical machines and the noise limits - Part 3: Noise limits (GB 10069.3-2008, IEC 60034-9: 2007, IDT) GB/T 23479.2 Wind turbine - Double-fed asynchronous generator - Part 2: Testing methods JB/T 5811 Test method and limits of form-wound winding for alternating current low-voltage electrical machines JB/T 9615.2 Test limits of the interturn insulation on random wound winding for AC low-voltage machines 3 Terms and definitions For the purposes of this part, the terms and definitions given in GB/T 2900.25 and the following apply. 3.1 doubly-fed asynchronous generator variable speed constant frequency generator in which the stator and rotor are directly or indirectly connected to the power grid and capable of exchanging energy 3.2 operating speed range speed range, namely, nmin~nmax, within which the generator shall be able to operate reliably when the synchronous speed of the generator is taken as the basic speed value (n0), where nmin is the speed corresponding to the cut-in wind speed of the wind turbine (nminn0)
Contents of GB/T 23479.1-2009
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Symbols and units 5 Model, type of construction, main parameter series and rating 6 Technical requirements 7 Testing method 8 Inspection rules 9 Sampling method and judgment rules 10 Safety and warning signs 11 Product information 12 Packaging, transport and storage
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 23479.1-2009, GB 23479.1-2009, GBT 23479.1-2009, GB/T23479.1-2009, GB/T 23479.1, GB/T23479.1, GB23479.1-2009, GB 23479.1, GB23479.1, GBT23479.1-2009, GBT 23479.1, GBT23479.1