Standard No.: GB/T 28886-2023
English Name: Plastic windows and doors for buildings
Chinese Name: 建筑用塑料门窗
Chinese Classification: P32    Building construction and decoration engineering
Professional Classification: GB    National Standard
ICS Classification: 91.060.50 91.060.50    Doors and windows 91.060.50
Issued by: SAMR; SAC
Issued on: 2023-12-28
Implemented on: 2024-7-1
Status: valid
Superseding:GB/T 28886-2012 Plastic door for buildings
GB/T 28887-2012 Plastic window for buildings
Language: English
File Format: PDF
Word Count: 19000 words
Price(USD): 570.0
Delivery: via email in 1 business day
GB/T 28886-2023 Plastic windows and doors for buildings 1 Scope This document specifies the classification, specifications, system and labeling, general requirements, technical requirements, test methods, inspection rules, marking and accompanying documents, as well as packaging, transportation and storage of plastic windows and doors for buildings. It is applicable to PVC-U plastic windows and doors for buildings. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2518 Continuously hot-dip zinc and zinc alloy coated steel sheet and strip GB/T 3098.21 Mechanical properties of fasteners - Stainless steel tapping screws GB/T 5237.1 Wrought aluminium alloy extruded profiles for architecture - Part 1: Untreated profiles GB/T 5237.2 Wrought aluminium alloy extruded profiles for architecture - Part 2: Anodized profiles GB/T 5237.3 Wrought aluminium alloy extruded profiles for architecture - Part 3: Electrodeposition coating profiles GB/T 5237.4 Wrought aluminium alloy extruded profiles for architecture - Part 4: Powder coating profiles GB/T 5237.5 Wrought aluminium alloy extruded profiles for architecture - Part 5 : Paint coating profiles GB/T 5823 Terminology for building windows and doors GB/T 5824 Size system of opening for windows and doors in building GB/T 6723 Cold forming open section steel for general structure GB/T 6728 Cold forming hollow sectional steel for general structure GB/T 7106 Test methods of air permeability, watertightness, wind load resistance performance for building external windows and doors GB/T 8484 Test method for thermal insulating performance for building exterior doors and windows GB/T 8485 Graduation and test method for airborne sound insulating properties of windows and doors GB/T 8814 Unplasticized polyvinyl chloride (PVC-U) profiles for the doors and windows GB/T 9158 Test methods of mechanics performance for windows and doors in building GB/T 11253 Cold-rolled sheet and strip of carbon structural steels GB/T 11793 Test methods on mechanical and weathering properties for unplasticized polyvinyl chloride (PVC-U) doors and windows GB/T 11944 Insulating glass unit GB/T 11976 Graduation and test method of daylighting properties for external windows GB/T 14155 Doorsets - Soft heavy body impact test GB/T 14683 Silicone and modified silicone sealants for building GB 15763.1 Safety glazing materials in building - Part 1: Fire-resistant glass GB 15763.2 Safety glazing materials in building - Part 2: Tempered glass GB 16807 Fire intumescent seals GB/T 24267 Building sealants for fire resistance GB/T 24498 Gaskets for doors, windows and curtain walls of buildings GB/T 29049 Doorsets - Vertical load test GB/T 29530 Hinged or pivoted doors - Determination of the resistance to static torsion GB/T 29739 Test method of resistance to repeat opening and closing for windows and doors GB/T 30591 Requirements for size coordination for opening of windows and doors in building GB/T 31433 General specification for building curtain walls, windows and doors GB/T 32223 Building hardware for windows and doors - General requirements GB/T 38252 Test method of fire-resistant integrity for building windows and doors GB/T 38586 Vacuum insulating glass JC/T 2304 Technical specification of energy efficient glass for building JC/T 2450 Glass used in the transparent part of passive building JG/T 176 Function structure measurement of plastic window/door and profile JG/T 386 Complex weatherstrip for doors and windows of buildings JG/T 440 Test method for shading performance of windows and doors JG/T 455 Tempered glass for window, door and curtain wall in buildings JGJ 113 Technical specification for application of architectural glass JGJ/T 151 Calculation specification for thermal performance of windows, doors and glass curtain-walls JGJ 362 Technical specification for design and fabricating of plastic doors and windows 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 5823, GB/T 5824 and GB/T 8814, as well as the following apply.   3.1 plastic doors doors adopting unplasticized polyvinyl chloride (PVC-U) profiles as base material and lined with reinforced material 3.2 plastic windows windows adopting unplasticized polyvinyl chloride (PVC-U) profiles as base material and lined with reinforced material 3.3 plastic windows and doors generic name for plastic doors and plastic windows 3.4 aluminum cladding plastic windows and doors plastic windows and doors decorated with aluminum gusset plates at external part of the plastic profiles 3.5 PBT reinforced PVC-U windows and doors windows and doors processed and manufactured by co-extruded composite profile, which are composed of polyester reinforced material PBT and PVC-U 3.6 mechanical joint connection between the profiles via special connectors 3.7 transom or mullion generic name for transom, mullion and stile of windows and doors
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Classification, specifications, system and labeling 5 Common requirements 6 Technical requirements 8 Inspection rules 9 Marking and accompanying documents 10 Packaging, transportation and storage Annex A (Informative) Standard lists for common materials Annex B (Normative) Technical requirements of reinforced steel Annex C (Informative) Inertia moment of reinforced steel Annex D (Informative) Common configuration and heat transfer coefficient of plastic side-hung window
Referred in GB/T 28886-2023:
*GB/T 2518-2019 Continuously hot-dip zinc and zinc alloy coated steel sheet and strip
*GB/T 3098.21-2014 Mechanical properties of fasteners. Stainless steel tapping screws
*GB/T 5237.1-2017 Wrought aluminium alloy extruded profiles for architecture - Part 1: Mill finish profiles
*GB/T 5237.2-2017 Wrought aluminium alloy extruded profiles for architecture - Part 2: Anodized profiles
*GB/T 5237.3-2017 Wrought aluminium alloy extruded profiles for architeature - Part 3: Electrophoretic coating profiles
*GB/T 5237.4-2017 Wrought aluminium alloy extruded profiles for architecture - Part 4:Powder coating profiles
*GB/T 5237.5-2017 Wrought aluminium alloy extruded profiles for architecture - Part 5: Paint coating profiles
*GB/T 5823-2008 Terminology for building windows and doors
*GB/T 5824-2021 Size system of opening for windows and doors in building
*GB/T 6723-2017 Cold forming open section steel for general structure
*GB/T 6728-2017 Cold forming hollow sectional steel for general structure
*GB/T 7106-2019 Test methods of air permeability,watertightness,wind load resistance performance for building external windows and doors
*GB/T 8484-2020 Test method for thermal insulating performance for building exterior doors and windows
*GB/T 8485-2008 The graduation and test for airborne sound insulating properties of windows and doors
*GB/T 8814-2017 Unplasticized polyvinyl chloride(PVC-Uprofiles for the doors and windows
*GB/T 9158-2015 Test methods of mechanics performance for windows and doors in building
*GB/T 11253-2019 Cold-rolled sheet and strip of carbon structural steels
*GB/T 11793-2008 Test methods on mechanical and weathering properties for unplasticized polyvinyl chloride (PVC-U) doors and windows
*GB/T 11944-2012 Insulating glass unit
*GB/T 11976-2015 Graduation and test method of daylighting properties for external windows
*GB/T 14155-2008 Doorsets - Soft heavy body impact test
*GB/T 14683-2017 Silicone and modified silicone sealants for building
*GB 15763.1-2009 Safety glazing materials in building - Part 1: Fire-resistant glass
*GB 15763.2-2005 Safety glazing materials in building?Part 2:Tempered glass
*GB 16807-2009 Fire intumescent seals
*GB/T 24267-2009 Building sealants for fire resistance
*GB/T 24498-2009 Gaskets for doors,windows and curtain walls of buildings
*GB/T 29049-2012 Doorsets—Vertical load test
*GB/T 29530-2013 Hinged or pivoted doors—Determination of the resistance to static torsion
*GB/T 29739-2013 Test method of resistance to repeat opening and closing for windows and doors
*GB/T 30591-2014 Requirements for size coordination for opening of windows and doors in building
*GB/T 31433-2015 General specification for building curtain walls,windows and doors
*GB/T 32223-2015 Building hardware for windows and doors―General requirements
*GB/T 38252-2019 Test method of fire-resistant integrity for building windows and doors
*GB/T 38586-2020 Vacuum insulating glass
*JC/T 2304-2015 The technical specification of energy efficient glass for building
*JC/T 2450-2018 Glass used in the transparent part of passive building
*JG/T 176-2015 Function Structure Measurement of Plastic Window/Door and Profile
*JG/T 386-2012 Complex Weatherstrip for Doors and Windows of Buildings
*JG/T 440-2014 Test Method for Shading Performance of Windows and Doors
*JG/T 455-2014 Tempered Glass for Window, Door and Curtain Wall in Buildings
*JGJ 113-2015 Technical specification for application of architectural glass
*JGJ/T 151-2008 Calculation specification for thermal performance of windows,doors and glass curtain-walls
*JGJ 362-2016 Technical Specification on Design and Assembly of Plastic Door and Window
Code of China
Standard
GB/T 28886-2023  Plastic windows and doors for buildings (English Version)
Standard No.GB/T 28886-2023
Statusvalid
LanguageEnglish
File FormatPDF
Word Count19000 words
Price(USD)570.0
Implemented on2024-7-1
Deliveryvia email in 1 business day
Detail of GB/T 28886-2023
Standard No.
GB/T 28886-2023
English Name
Plastic windows and doors for buildings
Chinese Name
建筑用塑料门窗
Chinese Classification
P32
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2023-12-28
Implemented on
2024-7-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 28886-2012 Plastic door for buildings
GB/T 28887-2012 Plastic window for buildings
Language
English
File Format
PDF
Word Count
19000 words
Price(USD)
570.0
Keywords
GB/T 28886-2023, GB 28886-2023, GBT 28886-2023, GB/T28886-2023, GB/T 28886, GB/T28886, GB28886-2023, GB 28886, GB28886, GBT28886-2023, GBT 28886, GBT28886
Introduction of GB/T 28886-2023
GB/T 28886-2023 Plastic windows and doors for buildings 1 Scope This document specifies the classification, specifications, system and labeling, general requirements, technical requirements, test methods, inspection rules, marking and accompanying documents, as well as packaging, transportation and storage of plastic windows and doors for buildings. It is applicable to PVC-U plastic windows and doors for buildings. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2518 Continuously hot-dip zinc and zinc alloy coated steel sheet and strip GB/T 3098.21 Mechanical properties of fasteners - Stainless steel tapping screws GB/T 5237.1 Wrought aluminium alloy extruded profiles for architecture - Part 1: Untreated profiles GB/T 5237.2 Wrought aluminium alloy extruded profiles for architecture - Part 2: Anodized profiles GB/T 5237.3 Wrought aluminium alloy extruded profiles for architecture - Part 3: Electrodeposition coating profiles GB/T 5237.4 Wrought aluminium alloy extruded profiles for architecture - Part 4: Powder coating profiles GB/T 5237.5 Wrought aluminium alloy extruded profiles for architecture - Part 5 : Paint coating profiles GB/T 5823 Terminology for building windows and doors GB/T 5824 Size system of opening for windows and doors in building GB/T 6723 Cold forming open section steel for general structure GB/T 6728 Cold forming hollow sectional steel for general structure GB/T 7106 Test methods of air permeability, watertightness, wind load resistance performance for building external windows and doors GB/T 8484 Test method for thermal insulating performance for building exterior doors and windows GB/T 8485 Graduation and test method for airborne sound insulating properties of windows and doors GB/T 8814 Unplasticized polyvinyl chloride (PVC-U) profiles for the doors and windows GB/T 9158 Test methods of mechanics performance for windows and doors in building GB/T 11253 Cold-rolled sheet and strip of carbon structural steels GB/T 11793 Test methods on mechanical and weathering properties for unplasticized polyvinyl chloride (PVC-U) doors and windows GB/T 11944 Insulating glass unit GB/T 11976 Graduation and test method of daylighting properties for external windows GB/T 14155 Doorsets - Soft heavy body impact test GB/T 14683 Silicone and modified silicone sealants for building GB 15763.1 Safety glazing materials in building - Part 1: Fire-resistant glass GB 15763.2 Safety glazing materials in building - Part 2: Tempered glass GB 16807 Fire intumescent seals GB/T 24267 Building sealants for fire resistance GB/T 24498 Gaskets for doors, windows and curtain walls of buildings GB/T 29049 Doorsets - Vertical load test GB/T 29530 Hinged or pivoted doors - Determination of the resistance to static torsion GB/T 29739 Test method of resistance to repeat opening and closing for windows and doors GB/T 30591 Requirements for size coordination for opening of windows and doors in building GB/T 31433 General specification for building curtain walls, windows and doors GB/T 32223 Building hardware for windows and doors - General requirements GB/T 38252 Test method of fire-resistant integrity for building windows and doors GB/T 38586 Vacuum insulating glass JC/T 2304 Technical specification of energy efficient glass for building JC/T 2450 Glass used in the transparent part of passive building JG/T 176 Function structure measurement of plastic window/door and profile JG/T 386 Complex weatherstrip for doors and windows of buildings JG/T 440 Test method for shading performance of windows and doors JG/T 455 Tempered glass for window, door and curtain wall in buildings JGJ 113 Technical specification for application of architectural glass JGJ/T 151 Calculation specification for thermal performance of windows, doors and glass curtain-walls JGJ 362 Technical specification for design and fabricating of plastic doors and windows 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 5823, GB/T 5824 and GB/T 8814, as well as the following apply.   3.1 plastic doors doors adopting unplasticized polyvinyl chloride (PVC-U) profiles as base material and lined with reinforced material 3.2 plastic windows windows adopting unplasticized polyvinyl chloride (PVC-U) profiles as base material and lined with reinforced material 3.3 plastic windows and doors generic name for plastic doors and plastic windows 3.4 aluminum cladding plastic windows and doors plastic windows and doors decorated with aluminum gusset plates at external part of the plastic profiles 3.5 PBT reinforced PVC-U windows and doors windows and doors processed and manufactured by co-extruded composite profile, which are composed of polyester reinforced material PBT and PVC-U 3.6 mechanical joint connection between the profiles via special connectors 3.7 transom or mullion generic name for transom, mullion and stile of windows and doors
Contents of GB/T 28886-2023
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Classification, specifications, system and labeling 5 Common requirements 6 Technical requirements 8 Inspection rules 9 Marking and accompanying documents 10 Packaging, transportation and storage Annex A (Informative) Standard lists for common materials Annex B (Normative) Technical requirements of reinforced steel Annex C (Informative) Inertia moment of reinforced steel Annex D (Informative) Common configuration and heat transfer coefficient of plastic side-hung window