GB/T 36035-2018/XG1-2022   Pharmaceutical machinery-General requirements for electrical safety, includes Amendment 1 (English Version)
Standard No.: GB/T 36035-2018/XG1-2022 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 7500 words Translation Price(USD):225.0 remind me the price change

Email:

Implemented on:2023-4-1 Delivery: via email in 1 business day

→ → →

,,2023-4-1,F7650580335FB8491674485174843
Standard No.: GB/T 36035-2018/XG1-2022
English Name: Pharmaceutical machinery-General requirements for electrical safety, includes Amendment 1
Chinese Name: 《制药机械 电气安全通用要求》国家标准第1号修改单
Chinese Classification: C90    Pharmaceutical, safety machinery and tool in general
Professional Classification: GB    National Standard
Source Content Issued by: AQSIQ; SAC
Issued on: 2022-12-30
Implemented on: 2023-4-1
Status: valid
Superseding:GB/T 36035-2018 Pharmaceutical machinery—General requirements for electrical safety, includes Amendment 1
Target Language: English
File Format: PDF
Word Count: 7500 words
Translation Price(USD): 225.0
Delivery: via email in 1 business day
Pharmaceutical machinery - General requirements for electrical safety 1 Scope This standard specifies the terms and definitions, power source and environment, electric shock protection, insulation protection, protective circuit, control devices, electrical safety protection in atmospheres with explosive media, electrical requirements in atmospheres with biosafety requirements, wiring, rated input power, electrical marking and technical documents involved in the general requirements for electrical safety of pharmaceutical machinery. This standard is applicable to the electrical safety of pharmaceutical machinery (equipment) (hereinafter referred to as the equipment). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 2894-2008 Safety signs and guideline for the use GB 3836.1-2010 Explosive atmospheres - Part 1: Equipment - General requirements GB 3836.2-2010 Explosive atmospheres - Part 2: Equipment protection by flameproof enclosures "d" GB 3836.3-2010 Explosive atmospheres - Part 3: Equipment protection by increased safety "e" GB 3836.4-2010 Explosive atmospheres - Part 4: Equipment protection by intrinsic safety "i" GB/T 3836.5-2017 Explosive atmospheres - Part 5: Equipment protection by pressurized enclosure "p" GB/T 3836.6-2017 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" GB/T 3836.7-2017 Explosive atmospheres - Part 7: Equipment protection by powder filling "q" GB 3836.8-2014 Explosive atmospheres - Part 8: Equipment protection by type of protection "n" GB 3836.9-2014 Explosive atmospheres - Part 9: Equipment protection by type of protection "m" GB 5226.1-2008 Electrical safety of machinery - Electrical equipment of machines - Part 1: General requirements GB/T 5465.2-2008 Graphical symbols for use on electrical equipment - Part 2: Graphical symbols GB 12476.1-2013 Electrical apparatus for use in the presence of combustible dust - Part 1: General requirements GB 12476.4-2010 Electrical apparatus for use in the presence of combustible dust - Part 4: Protection by intrinsic safety "iD" GB 12476.5-2013 Electrical apparatus for use in the presence of combustible dust - Part 5: Protection by enclosures "tD" GB 12476.6-2010 Electrical apparatus for use in the presence of combustible dust - Part 6: Protection by encapsulation "mD" GB 12476.7-2010 Electrical apparatus for use in the presence of combustible dust - Part 7: Type of protection "pD" HG 20660-2000(2009) Standard for classification on hazards of toxicity and explosion of chemical mediums in pressure vessel ISO 7000 Graphical symbols for use on equipment 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 pharmaceutical machinery production equipment to complete and assist in the completion of pharmaceutical process [GB/T 15692-2008, Definition 2.1] 3.2 rated (value) quantity value assigned, generally by a manufacturer, to a specified operating condition of a component, device or equipment [GB 4793.1-2007, Definition 3.3.1] 3.3 mains low-voltage electricity supply system to which the equipment concerned is designed to be connected for the purpose of powering the equipment Note: Some measuring circuits may also be connected to the mains for measuring purposes. [GB 4793.1-2007, Definition 3.5.5]   3.4 normal condition condition in which all means for protection against hazards are intact [GB 4793.1-2007, Definition 3.5.10] 3.5 single fault condition condition in which one means for protection against hazard is defective or one fault is present which could cause a hazard [GB 4793.1-2007, Definition 3.5.11] 3.6 accessible (of a part) part of equipment that can be touched without tools [GB 4793.1-2007, Definition 3.5.1]
Foreword I 1 Scope 2 Normative references 3 Terms and definitions 4 Power source and environment 5 Electric shock protection 6 Insulation protection 7 Protective circuit 8 Control devices 9 Electrical safety protection in atmospheres with explosive media 10 Electrical requirements in atmospheres with biosafety requirements 11 Wiring 12 Rated input power 13 Electrical marking 14 Technical documents Annex A (Normative) Measuring circuit for leakage current limits Bibliography
Referred in GB/T 36035-2018/XG1-2022:
*GB 2894-2008 Safety Signs and Guideline for the Use
*GB 3836.1-2010 Explosive atmospheres—Part 1:Equipment—General requirements
*GB 3836.2-2010 Explosive atmospheres—Part 2:Equipment protection by flameproof enclosures“d”
*GB 3836.3-2010 Explosive atmospheres - Part 3:Equipment protection by increased safety e
*GB 3836.4-2010 Explosive atmospheres—Part 4:Equipment protection by intrinsic safety i
*GB/T 3836.5-2017 Explosive atmospheres-Part 5:Equipment protection by pressurized enclosure"p"
*GB/T 3836.6-2017 Explosive atmospheres―Part 6:Equipment protection by liquid immersion“o”
*GB/T 3836.7-2017 Explosive atmospheres―Part 7:Equipment protection by powder filling“q”
*GB 3836.8-2014 Explosive atmospheres―Part 8:Equipment protection by type of protection “n”
*GB 3836.9-2014 Explosive atmospheres―Part 9:Equipment protection by type of protection “m”
*GB 5226.1-2008 Electrical Safety of Machinery - Electrical Equipment of Machines - Part 1: General Requirements
*GB/T 5465.2-2008 Graphical Symbols for Use on Electrical Equipment - Part 2: Graphical Symbols
*GB 12476.1-2013 Electrical Apparatus for Use in the Presence of Combustible Dust - Part 1: General Requirements
*GB 12476.4-2010 Electrical apparatus for use in the presence of combustible dust—Part 4:Protection by intrinsic safety“iD”
*GB 12476.5-2013 Electrical Apparatus for Use in the Presence of Combustible Dust - Part 5: Protection by Enclosures “tD”
*GB 12476.6-2010 Electrical apparatus for use in the presence of combustible dust—Part 6:Protection by encapsulation mD
*GB 12476.7-2010 Electrical apparatus for use in the presence of combustible dust—Part 7:Type of protection pD
*HG20660-2000(2009)
Code of China
Standard
GB/T 36035-2018/XG1-2022  Pharmaceutical machinery-General requirements for electrical safety, includes Amendment 1 (English Version)
Standard No.GB/T 36035-2018/XG1-2022
Statusvalid
LanguageEnglish
File FormatPDF
Word Count7500 words
Price(USD)225.0
Implemented on2023-4-1
Deliveryvia email in 1 business day
Detail of GB/T 36035-2018/XG1-2022
Standard No.
GB/T 36035-2018/XG1-2022
English Name
Pharmaceutical machinery-General requirements for electrical safety, includes Amendment 1
Chinese Name
《制药机械 电气安全通用要求》国家标准第1号修改单
Chinese Classification
C90
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2022-12-30
Implemented on
2023-4-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 36035-2018 Pharmaceutical machinery—General requirements for electrical safety, includes Amendment 1
Language
English
File Format
PDF
Word Count
7500 words
Price(USD)
225.0
Keywords
GB/T 36035-2018/XG1-2022, GB 36035-2018/XG1-2022, GB 36035-2018XG1-2022, GB/T36035-2018/XG1-2022, GB/T 36035, GB/T36035, GB36035-2018/XG1-2022, GB 36035, GB36035, GB36035-2018XG1-2022, GB 36035, GB36035
Introduction of GB/T 36035-2018/XG1-2022
Pharmaceutical machinery - General requirements for electrical safety 1 Scope This standard specifies the terms and definitions, power source and environment, electric shock protection, insulation protection, protective circuit, control devices, electrical safety protection in atmospheres with explosive media, electrical requirements in atmospheres with biosafety requirements, wiring, rated input power, electrical marking and technical documents involved in the general requirements for electrical safety of pharmaceutical machinery. This standard is applicable to the electrical safety of pharmaceutical machinery (equipment) (hereinafter referred to as the equipment). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 2894-2008 Safety signs and guideline for the use GB 3836.1-2010 Explosive atmospheres - Part 1: Equipment - General requirements GB 3836.2-2010 Explosive atmospheres - Part 2: Equipment protection by flameproof enclosures "d" GB 3836.3-2010 Explosive atmospheres - Part 3: Equipment protection by increased safety "e" GB 3836.4-2010 Explosive atmospheres - Part 4: Equipment protection by intrinsic safety "i" GB/T 3836.5-2017 Explosive atmospheres - Part 5: Equipment protection by pressurized enclosure "p" GB/T 3836.6-2017 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" GB/T 3836.7-2017 Explosive atmospheres - Part 7: Equipment protection by powder filling "q" GB 3836.8-2014 Explosive atmospheres - Part 8: Equipment protection by type of protection "n" GB 3836.9-2014 Explosive atmospheres - Part 9: Equipment protection by type of protection "m" GB 5226.1-2008 Electrical safety of machinery - Electrical equipment of machines - Part 1: General requirements GB/T 5465.2-2008 Graphical symbols for use on electrical equipment - Part 2: Graphical symbols GB 12476.1-2013 Electrical apparatus for use in the presence of combustible dust - Part 1: General requirements GB 12476.4-2010 Electrical apparatus for use in the presence of combustible dust - Part 4: Protection by intrinsic safety "iD" GB 12476.5-2013 Electrical apparatus for use in the presence of combustible dust - Part 5: Protection by enclosures "tD" GB 12476.6-2010 Electrical apparatus for use in the presence of combustible dust - Part 6: Protection by encapsulation "mD" GB 12476.7-2010 Electrical apparatus for use in the presence of combustible dust - Part 7: Type of protection "pD" HG 20660-2000(2009) Standard for classification on hazards of toxicity and explosion of chemical mediums in pressure vessel ISO 7000 Graphical symbols for use on equipment 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 pharmaceutical machinery production equipment to complete and assist in the completion of pharmaceutical process [GB/T 15692-2008, Definition 2.1] 3.2 rated (value) quantity value assigned, generally by a manufacturer, to a specified operating condition of a component, device or equipment [GB 4793.1-2007, Definition 3.3.1] 3.3 mains low-voltage electricity supply system to which the equipment concerned is designed to be connected for the purpose of powering the equipment Note: Some measuring circuits may also be connected to the mains for measuring purposes. [GB 4793.1-2007, Definition 3.5.5]   3.4 normal condition condition in which all means for protection against hazards are intact [GB 4793.1-2007, Definition 3.5.10] 3.5 single fault condition condition in which one means for protection against hazard is defective or one fault is present which could cause a hazard [GB 4793.1-2007, Definition 3.5.11] 3.6 accessible (of a part) part of equipment that can be touched without tools [GB 4793.1-2007, Definition 3.5.1]
Contents of GB/T 36035-2018/XG1-2022
Foreword I 1 Scope 2 Normative references 3 Terms and definitions 4 Power source and environment 5 Electric shock protection 6 Insulation protection 7 Protective circuit 8 Control devices 9 Electrical safety protection in atmospheres with explosive media 10 Electrical requirements in atmospheres with biosafety requirements 11 Wiring 12 Rated input power 13 Electrical marking 14 Technical documents Annex A (Normative) Measuring circuit for leakage current limits Bibliography