2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JB/T 10491.1-2004
JB/T 10491.1-2004   Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V Part1: General requirements (English Version)
Standard No.: JB/T 10491.1-2004 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 6000 words Translation Price(USD):150.0 remind me the price change

Email:

Implemented on:2005-4-1 Delivery: via email in 1 business day

→ → →

,2023-4-1,2005-4-1,14113742804724E15E9925602498A
Standard No.: JB/T 10491.1-2004
English Name: Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V Part1: General requirements
Chinese Name: 额定电压450/750V及以下交联聚烯烃绝缘电线和电缆 第1部分:一般规定
Chinese Classification: K13    Cable and its accessory
Professional Classification: JB    Professional Standard - Machinery
ICS Classification: 29.060.01 29.060.01    Electrical wires and cables in general 29.060.01
Source Content Issued by: NDRC
Issued on: 2004-10-20
Implemented on: 2005-4-1
Status: superseded
Superseded by:JB/T 10491-2022
Superseded on:2023-4-1
Target Language: English
File Format: PDF
Word Count: 6000 words
Translation Price(USD): 150.0
Delivery: via email in 1 business day
1 Scope This part specifies the product structure, general technical requirements, tests, acceptance rules, delivery length, marking and packaging of cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V. This part is applicable to cross-linked polyolefin insulated wires and cables (copper conductor) with rated voltages up to and including 450/750V and with heat resistant requirements for fixed wiring and for internal connection of power and electronic equipment. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of JB/T 10491. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this part. However parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. GB/T 2900.10 Electrotechnical terminology - Electric cables (GB/T 2900.10-2001; idt IEC 60050 (461): 1984) GB/T 2951.1-1997 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section one: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties (idt IEC 60811-1-1: 1993) GB/T 2951.2-1997 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section two: Thermal ageing methods (idt IEC 60811-1-2: 1985) GB/T 2951.3-1997 Common test methods for insulating and sheathing materials of electric cable - Part 1: Methods for general application - Section three: Methods for determining the density - Water absorption tests - Shrinkage test (idt IEC 60811-1-3: 1993) GB/T 2951.4-1997 Common test methods for insulating and sheathing material of electric cables - Part 1: Methods for general application - Section four: Test at low temperature (idt IEC 60811-1-4: 1985) GB/T 2951.5-1997 Common test methods for insulating and sheathing materials of electric cables - Part 2: Methods specific to elastomeric compounds - Section one: Ozone resistance test - Hot set test - Mineral oil immersion test (idt IEC 60811-2-1: 1986) GB/T 3956 Conductors of insulated cables (GB/T 3956-1997; idt IEC 60228: 1978) GB/T 17650.2 Test on gases evolved during combustion of materials from cables - Part 2: Determination of degree of acidity of gases by measuring pH and conductivity (GB/T 37650.2-1998; idt IEC 60754-2: 1991) GB/T 17651.2 Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements (GB/T 17651.2-1998; idt IEC 61034-2: 1997) GB/T 18380.1 Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable (GB/T 18380.1-2001; idt IEC 60332-1: 1993) GB/T 18380.2 Tests on electric cables under fire conditions - Part 2: Test on a single small vertical insulated copper wire or cable (GB/T 18380.2-2001; idt IEC 60332-2: 1989) GB/T 18380.3 Tests on electric cables under fire conditions - Part 3: Tests on bunched wires or cables (GB/T 18380.3-2001; idt IEC 60332-3: 1992) JB/T 8137.1~4 Delivery drums for electric wires and cables JB/T 10491.2-2004 Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V - Part2: Cross-linked polyolefin insulated wires and cables for maximum conductor temperature of 105℃ in normal operation JB/T 10491.3-2004 Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V - Part 3: cross-linked polyolefin insulated wires and cables for maximum conductor temperature of 125℃ in normal operation IEC 60332-3 Tests on electric cables under fire conditions - Part 3: Test on bunched wires or cables 3 Terms and definitions For the purposes of this part, the terms and definitions given in GB/T 2900.10 and the following apply. 3.1 Terms cross-linked polyolefin
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 3.1 Terms 3.2 Definitions 4 Symbols and codes 4.1 Symbols and codes 4.2 Product expressions 5 General requirements for cable structure 5.1 Conductor 5.2 Insulation 5.3 Filling 5.4 Sheath 5.5 Marking 6 Test for finished cables 6.1 Mechanical and physical properties of insulation and sheath 6.2 Electrical property 6.3 Overall dimension 6.4 Test for combustion performance of cable 7 Test method 7.1 Conductor resistance 7.2 Voltage test of finished cables 7.3 Voltage test of insulated cores 7.4 Test for insulation resistance at temperature above 90℃ 7.5 Inspection for scuff resistance of colors and markings 7.6 Measurement of insulation thickness 7.7 Measurement of sheath thickness 7.8 Measurement of overall dimension and ovality 8 Delivery length 9 Acceptance rules 10 Marking and packaging Table 1 Mechanical and physical properties of cross-linked polyolefin insulation (XPO) Table 2 Mechanical and physical properties of cross-linked polyolefin sheath (SXE) Table 3 Requirements for electrical property test of cross-linked polyolefin insulated cables
Referred in JB/T 10491.1-2004:
*GB/T 2900.10-2013 Electrotechnical Terminology - Electric Cables
*GB/T 2951.1-1997 Common test methods for insulating and sheating materials of electric cables Part 1:Methods for general application Section one:Measurement of thickness and overall dimensions―Tests for determining the mechanical properties
*GB/T 2951.2-1997 Common test methods for insulating and sheating materials of electric cables--Part 1: Methods for general application--Section two: Thermal ageing methods
*GB/T 2951.3-1997 Common test methods for insulating and sheathing materials of electric cable--Part 1: Methods for general application--Section three: Methods for determining the density--Water absorption tests--Shrinkage test
*GB/T 2951.4-1997 Common test methods for insulating and sheathing materials of electric cables Part 1: Methods for general application
*GB/T 2951.5-1997 Common test methods for insulating and sheathing materials of electric cables--Part 2: Methods specific to elastomeric compounds section one--Ozone resistance test--Hot set test--Mineral oil immersion test
*GB/T 3956-2008 Conductors of insulated cables
*GB/T 17650.2-1998 Test on gases evolved during combustion of materials from cables - Part 2: Determination of degree of acidity of gases by measuring pH and conductivity
*GB/T 17651.2-1998 Measurement of smoke density of cables burning under defined conditions - Part 2 : Test procedure and requirements
*GB/T 18380.1-2001 Tests on electric cables under fire conditions-Part 1:Test on a single vertical insulated wire or cable
*GB/T 18380.2-2001 Tests on electric cables under fire conditions-Part 2:Test on a single small vertical insulated copper wire or cable
*GB/T 18380.3-2001 Tests on electric cables under fire conditions-Part 3:Tests on bunched wires or cables
*JB/T 10491.2-2004 Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V Part2:
*JB/T 10491.3-2004 Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V Part3:
JB/T 10491.1-2004 is referred in:
*JB/T 10491.2-2004 Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V Part2:
Code of China
Standard
JB/T 10491.1-2004   Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V Part1: General requirements (English Version)
Standard No.JB/T 10491.1-2004
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)150.0
Implemented on2005-4-1
Deliveryvia email in 1 business day
Detail of JB/T 10491.1-2004
Standard No.
JB/T 10491.1-2004
English Name
Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V Part1: General requirements
Chinese Name
额定电压450/750V及以下交联聚烯烃绝缘电线和电缆 第1部分:一般规定
Chinese Classification
K13
Professional Classification
JB
ICS Classification
Issued by
NDRC
Issued on
2004-10-20
Implemented on
2005-4-1
Status
superseded
Superseded by
JB/T 10491-2022
Superseded on
2023-4-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
150.0
Keywords
JB/T 10491.1-2004, JB 10491.1-2004, JBT 10491.1-2004, JB/T10491.1-2004, JB/T 10491.1, JB/T10491.1, JB10491.1-2004, JB 10491.1, JB10491.1, JBT10491.1-2004, JBT 10491.1, JBT10491.1
Introduction of JB/T 10491.1-2004
1 Scope This part specifies the product structure, general technical requirements, tests, acceptance rules, delivery length, marking and packaging of cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V. This part is applicable to cross-linked polyolefin insulated wires and cables (copper conductor) with rated voltages up to and including 450/750V and with heat resistant requirements for fixed wiring and for internal connection of power and electronic equipment. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of JB/T 10491. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this part. However parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. GB/T 2900.10 Electrotechnical terminology - Electric cables (GB/T 2900.10-2001; idt IEC 60050 (461): 1984) GB/T 2951.1-1997 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section one: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties (idt IEC 60811-1-1: 1993) GB/T 2951.2-1997 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section two: Thermal ageing methods (idt IEC 60811-1-2: 1985) GB/T 2951.3-1997 Common test methods for insulating and sheathing materials of electric cable - Part 1: Methods for general application - Section three: Methods for determining the density - Water absorption tests - Shrinkage test (idt IEC 60811-1-3: 1993) GB/T 2951.4-1997 Common test methods for insulating and sheathing material of electric cables - Part 1: Methods for general application - Section four: Test at low temperature (idt IEC 60811-1-4: 1985) GB/T 2951.5-1997 Common test methods for insulating and sheathing materials of electric cables - Part 2: Methods specific to elastomeric compounds - Section one: Ozone resistance test - Hot set test - Mineral oil immersion test (idt IEC 60811-2-1: 1986) GB/T 3956 Conductors of insulated cables (GB/T 3956-1997; idt IEC 60228: 1978) GB/T 17650.2 Test on gases evolved during combustion of materials from cables - Part 2: Determination of degree of acidity of gases by measuring pH and conductivity (GB/T 37650.2-1998; idt IEC 60754-2: 1991) GB/T 17651.2 Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements (GB/T 17651.2-1998; idt IEC 61034-2: 1997) GB/T 18380.1 Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable (GB/T 18380.1-2001; idt IEC 60332-1: 1993) GB/T 18380.2 Tests on electric cables under fire conditions - Part 2: Test on a single small vertical insulated copper wire or cable (GB/T 18380.2-2001; idt IEC 60332-2: 1989) GB/T 18380.3 Tests on electric cables under fire conditions - Part 3: Tests on bunched wires or cables (GB/T 18380.3-2001; idt IEC 60332-3: 1992) JB/T 8137.1~4 Delivery drums for electric wires and cables JB/T 10491.2-2004 Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V - Part2: Cross-linked polyolefin insulated wires and cables for maximum conductor temperature of 105℃ in normal operation JB/T 10491.3-2004 Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V - Part 3: cross-linked polyolefin insulated wires and cables for maximum conductor temperature of 125℃ in normal operation IEC 60332-3 Tests on electric cables under fire conditions - Part 3: Test on bunched wires or cables 3 Terms and definitions For the purposes of this part, the terms and definitions given in GB/T 2900.10 and the following apply. 3.1 Terms cross-linked polyolefin
Contents of JB/T 10491.1-2004
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 3.1 Terms 3.2 Definitions 4 Symbols and codes 4.1 Symbols and codes 4.2 Product expressions 5 General requirements for cable structure 5.1 Conductor 5.2 Insulation 5.3 Filling 5.4 Sheath 5.5 Marking 6 Test for finished cables 6.1 Mechanical and physical properties of insulation and sheath 6.2 Electrical property 6.3 Overall dimension 6.4 Test for combustion performance of cable 7 Test method 7.1 Conductor resistance 7.2 Voltage test of finished cables 7.3 Voltage test of insulated cores 7.4 Test for insulation resistance at temperature above 90℃ 7.5 Inspection for scuff resistance of colors and markings 7.6 Measurement of insulation thickness 7.7 Measurement of sheath thickness 7.8 Measurement of overall dimension and ovality 8 Delivery length 9 Acceptance rules 10 Marking and packaging Table 1 Mechanical and physical properties of cross-linked polyolefin insulation (XPO) Table 2 Mechanical and physical properties of cross-linked polyolefin sheath (SXE) Table 3 Requirements for electrical property test of cross-linked polyolefin insulated cables
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JB/T 10491.1-2004, JB 10491.1-2004, JBT 10491.1-2004, JB/T10491.1-2004, JB/T 10491.1, JB/T10491.1, JB10491.1-2004, JB 10491.1, JB10491.1, JBT10491.1-2004, JBT 10491.1, JBT10491.1