2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JGJ 36-2016
JGJ 36-2016   Code for design of dormitory building (English Version)
Standard No.: JGJ 36-2016 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 13500 words Translation Price(USD):330.0 remind me the price change

Email:

Implemented on:2017-6-1 Delivery: via email in 1 business day

→ → →

,,2017-6-1,B49FCC5CBC72B7F11484575519347
Standard No.: JGJ 36-2016
English Name: Code for design of dormitory building
Chinese Name: 宿舍建筑设计规范
Professional Classification: JG    Professional Standard - Building
Source Content Issued by: MOHURD
Issued on: 2016-12-15
Implemented on: 2017-6-1
Status: valid
Superseding:JGJ 36-2005 Code for Design of Dormitory Building
Target Language: English
File Format: PDF
Word Count: 13500 words
Translation Price(USD): 330.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the contents of English translation, the Chinese original shall be considered authoritative. In accordance with "Notice on Printing the Development and Revision Plan on Engineering Construction Standards and Codes in 2014" (Jian Biao [2013] No. 169) of the Ministry of Housing and Urban-Rural Development, the specification drafting group, through extensive investigation and by reference to relevant international and foreign advanced standards, has revised this code by earnestly summarizing practical experience and widely soliciting opinions. The main technical contents of this code are as follows: 1. General Provisions; 2. Terms; 3. Site and General Layout; 4. Architectural Design; 5. Fire Protection and Safe Evacuation; 6. Indoor Environment; 7. Building equipment. The following technical deviations have been made in this code: 1. terms are modified and added; 2. foundation and outdoor environment are refined, and safety index is added; 3. classification and usable area standard of some bedrooms are modified and added; 4. the standard of appliance configuration in affiliating room is modified; 5. the clause of fire protection and safe evacuation is added. Provisions printed in bold type in this code are mandatory ones and must be implemented strictly. The Ministry of Housing and Urban-Rural Development is in charge of the administration of this code and the explanation of the compulsory provisions, and the China Institute of Building Standard Design & Research is responsible for the explanation of specific technical contents. During the process of implementing this specification, the relevant opinions and advice, whenever necessary, can be posted or passed on to China Institute of Building Standard Design & Research (Address: No.2 Building, No.9 Zhuyu International Commercial Center, Shouti South Road, Haidian District, Beijing, 100048).   Contents Foreword I 1 General Provisions 1 2 Terms 1 3 Site and General Layout 2 3.1 Site 2 3.2 General Layout 2 4 Architectural Design 3 4.1 General Requirements 3 4.2 Bedroom 4 4.3 Affiliating Room 5 4.4 Storey Height and Net Storey Height 7 4.5 Stairs and Elevator 7 4.6 Door, Window and Balcony 8 5 Fire Protection and Safe Evacuation 9 5.1 Fire Protection 9 5.2 Safe Evacuation 9 6 Indoor Environment 10 6.1 Natural Ventilation and Daylighting 10 6.2 Sound Insulation and Noise Reduction 11 6.3 Energy Efficiency 12 6.4 Indoor Air Quality 12 7 Building Equipment 13 7.1 Water Supply and Drainage 13 7.2 Heating, Ventilating and Air-conditioning 13 7.3 Building Electricity 14 Explanation of Wording in this Code 16 List of Quoted Standards 17 Code for Design of Dormitory Building 1 General Provisions 1.0.1 This standard is formulated with a view to implementing the national technical and economic policies in the design of dormitory building and making the design to be of usability, economy, green, aesthetic and high quality. 1.0.2 This code is applicable to design of newly constructed, renovated and extended dormitory building. 1.0.3 The design of dormitory building shall meet the requirements of the local urban and rural planning, the local climate and geographical conditions, and the social, economic and cultural development level. 1.0.4 The design of dormitory building shall not only meet the requirements of this code, but also meet those specified in the relevant national current standards of China. 2 Terms 2.0.1 dormitory residential buildings that are centrally managed and used by single person 2.0.2 bedroom, habitable room rooms for the occupants to sleep, study, and rest 2.0.3 lavatory, bathroom rooms for the occupants to urinate and defecate, bath, wash up and other activities. 2.0.4 public toilet public rooms for the occupants to urinate and defecate, wash hand 2.0.5 public washroom public rooms for the occupants to wash up, wash clothes and other activities 2.0.6 activity room public rooms for receiving, entertainment, small gatherings and other activities of the occupants 2.0.7 usable area the actual area in use of a room, excluding the area of walls, columns and other structural structures and insulation layer. 2.0.8 balcony the space, attached to the external walls of buildings, with a railing or balustrade, for the occupants to conduct outdoor activities, drying clothes and other activities 2.0.9 corridor the space for horizontal public traffic inside a building 2.0.10 store space the fixed space for goods storage (for example: wall cabinet, wall cupboard, special store room, etc.) 2.0.11 public kitchen the cooking room for food processing and cooking and shared by the occupants 3 Site and General Layout 3.1 Site 3.1.1 Dormitory shall not be built on the sites prone to serious geological hazards. 3.1.2 Dormitory site should be under sunshine conditions, daylighting and good ventilation. 3.1.3 The relative flat site and difficult of water accumulation should be selected for dormitory. 3.1.4 The dormitory shall be able to avoid the influence of noise and pollution sources, and shall meet the requirements of national current standards on health protection. 3.2 General Layout 3.2.1 The dormitory should have favorable outdoor environment. 3.2.2 The site design of dormitory shall be carried out, and there shall have perfect drainage facilities. 3.2.3 Dormitory building should be close to work and study place. It should be close to public canteen, commercial network, public bath and other supporting service facilities, and its service radius should not exceed 250m. 3.2.4 The main entrances and exits of dormitory building shall be provided with personnel distribution center, and the per capita area index shall not be less than 0.20m2. There should be centralized green space near the dormitory. 3.2.5 Distribution center and centralized green space should be simultaneously served as emergency shelter, which may be supplied with spare power source, water source, toilet/bath or drainage and other necessity facilities. 3.2.6 There shall be reasonable streamline design of personnel, non-motor vehicles and motor vehicles, so as to avoid motor vehicles passing through the dormitory area. 3.2.7 There shall be outdoor activity space and bicycle storage place near the dormitory; parking space for motor vehicles should be provided in the dormitory area, and parking spaces and charging facilities for electric cars may be provided or reserved. 3.2.8 The room interval of dormitory building shall meet the requirements of current national standards on fire protection and daylighting, and shall meet the relevant requirements of urban planning. 3.2.9 Accessible facilities shall be provided for public traffic space, foot path in the dormitory area and exits and entrances of dormitory, which shall comply with the relevant requirements of the current national standard Codes for Accessibility Design (GB 50763). 3.2.10 Identification system shall be installed in the dormitory area. 4 Architectural Design 4.1 General Requirements 4.1.1 The plane layout of dormitory may be in gallery type and unit type layout, and the horizontal traffic streamline of middle corridor type dormitory should not be too long. 4.1.2 Caretaker room, activity room and clothes drying space shall be set in each dormitory building. The arrangement of public rooms shall have no influence bedrooms. 4.1.3 Dormitory building shall meet the requirement of natural daylighting and air conditioning. Half and above bedrooms of dormitory building shall be good orientation. 4.1.4 The setting requirements of accessible bedrooms and accessible facilities of dormitory shall meet the relevant requirements of the current national standard Codes for Accessibility Design (GB 50763). 4.1.5 When dormitory with open and transparent side corridor and outside stairway, anti-rain facilities and anti-skid measures of floors shall be provided. Antiskid design of exit and entrance and platform, public corridor, elevator hall, bathroom, washroom, toilet shall meet the requirements of the current professional standard Technical Specification for Slip Resistance of Building Floor (JGJ/T 331). 4.1.6 When heating and air conditioning equipment are set up, the equipment foundation, shelf board and other building elements shall be integrated with the building. 4.1.7 When public exit and entrance of dormitory is located under the balcony, side corridor and open stair platform, safety protective measures to prevent person injured by falling objects shall be taken. 4.1.8 Design of dormitory building shall make use of industrialized construction technology, and shall comply with the relevant requirements of the current national standard Standard for Modular Coordination of Building (GB/T 50002). 4.2 Bedroom 4.2.1 Bedrooms of dormitory shall be classified into five types according to their service requirements, the usable area per capita of each type of bedroom should not be less than those specified in Table 4.2.1. Table 4.2.1 Type and Related Indexes of Bedroom Type Type 1 Type 2 Type 3 Type 4 Type 5 Number of occupants (count) per room 1 2 3 - 4 6 ≥8 Usable area per capita (m2/person) Bed, loft bed 16 8 6 — — Bunk bed — — — 5 4 Store space Wardrobe, wall cabinet, wall cupboard and bookshelf Note 1: The area in this table excluding the area of lavatory and balcony of bedroom; Note 2: The occupants of Type 5 dormitory should be 8 persons, and should not exceed 16 persons; Note 3: The area of bedroom for the disabled should be properly increased, and the occupants should not exceed 4 persons; wheelchair turning space with diameter not less than 1.5m shall be provided in the bedroom. 4.2.2 The arrangement of beds in bedroom shall meet the following requirements: 1 The distance between the long sides of two beds shall not be less than 0.60m, and shall not be less than 0.80m in accessible bedroom; 2 The distance between two bed heads shall not be less than 0.10m; 3 The width of walkway between two rows of beds, or between bed and wall, shall not be less than 1.20m, and wheelchair turning space shall be provided in the bedroom of the disabled; 4 The position of heating facilities shall be reasonably arranged in bedroom of heating area. 4.2.3 Store space shall be provided in bedroom, and net store space per capita should be 0.50m3 to 0.80m3; the net depth of clothes store space should not be less than 0.55m.When fixed luggage rack is provided, the clearance length of each lattice should not be less than 0.80m, the width should not be less than 0.60m, and the height should not be less than 0.45m. For the dimensions of bookshelf, the net depth shall not be less than 0.25m, and the net height of each lattice shall not be less than 0.35m. 4.2.4 For the wall surface adjacent to public washroom, public toilet, lavatory and other wet rooms of bedroom, damp-proof treatment for upstream face of adjacent wall shall be carried out. 4.2.5 Bedroom shall not be located basement. 4.2.6 Dormitory bedrooms of elementary and secondary schools shall not be located at semi-basement, and other dormitory bedrooms should not be located at semi-basement. 4.2.7 At least one accessible bedroom shall be set on the main entrance floor of dormitory building, and accessible bathroom should be set.
Foreword I 1 General Provisions 2 Terms 3 Site and General Layout 3.1 Site 3.2 General Layout 4 Architectural Design 4.1 General Requirements 4.2 Bedroom 4.3 Affiliating Room 4.4 Storey Height and Net Storey Height 4.5 Stairs and Elevator 4.6 Door, Window and Balcony 5 Fire Protection and Safe Evacuation 5.1 Fire Protection 5.2 Safe Evacuation 6 Indoor Environment 6.1 Natural Ventilation and Daylighting 6.2 Sound Insulation and Noise Reduction 6.3 Energy Efficiency 6.4 Indoor Air Quality 7 Building Equipment 7.1 Water Supply and Drainage 7.2 Heating, Ventilating and Air-conditioning 7.3 Building Electricity Explanation of Wording in this Code List of Quoted Standards
Referred in JGJ 36-2016:
*GB/T 50002-2013 Standard for modular coordination of buildings
*GB 50016-2014(2018)-Provisions Provisions of Code for Fire Protection Design of Buildings
*GB 50099-2011 Code for design of school
*GB 50222-2017 Code for Fire Prevention in Design of Interior Decoration of Buildings
*GB 50763-2012 Codes for accessibility design
*GB 5749-2022 Standards for drinking water quality
*JGJ/T 331-2014 Technical Specification for Slip Resistance of Buildings Floor
*GB/T 33271-2016 Woven garments for infants
*GB/T 22700-2016 Washed garments
*GB/T 18132-2016 Silk Garments
*WS 310.1-2016 Central sterile supply department(CSSD) Part 1:Management standard
*GB/T 33460-2016 Specifications for compiling dismantling manual of end-of-life vehicles
*WS 507-2016 Regulation for cleaning and disinfection technique of flexible endoscope
JGJ 36-2016 is referred in:
*GB 4789.35-2016 National food safety standard -Microbiological examination of food-Examination of lactic acid bacteria
*GB 4789.36-2016 National Food Safety Standard—Food Microbiological Examination—Examination of Escherichia Coli O157:H7/MN
*GB 4789.30-2016 National Food Safety Standard—Food Microbiological Examination—Examination of Listeria Monocytogenes
*GB 4789.40-2016 National Food Safety Standard—Food Microbiological Examination—Examination of Cronobacter (Enterobacter Sakazakii)
*GB 4789.43-2016 National Food Safety Standard - Food Microbiological Examination -Determination of Antibacterial Activity of Microbe-source Enzyme
*GB 5009.271-2016 National Food Safety Standard - Determination of Phthalates in Food
*GB 5009.270-2016 National Food Safety Standard--Determination of Inositol in Foods
*GB 5009.278-2016 National Food Safety Standard - Determination of Tetraacetate in Food
*SY/T 5553-2012 Labor quota for drilling engineering
*GB/T 28621-2012 Safety rules for the construction and installation of new lifts in existing building
*GB/T 17497.3-2012 Decorative products by flexographic printing—Part 3:Corrugated board
*GB 29401-2012 Sulfur coated urea(SCU)
*GB/T 14999.1-2012 Test method for superalloys - Part 1: Verification of longitudinal macro-structures and defect by etch
*GB 1103.2-2012 Cotton—Part 2:Roller ginned upland cotton
*GB/Z 29014-2012 Cutting tool data representation and exchange—Definitions,principles and methods for Reference dictionaries
*GB/T 239.2-2012 Metallic materials - Wire - Part 2: Reverse torsion test
*GB 5413.30-2016 National Food Safety Standard Determination of Impurities in Milk and Milk Products
*GB 5009.268-2016 National Food Safety Standard--Determination of Multi-elements in Foods
*JT/T 719-2016 Limits and measurement methods of fuel consumption for commercial vehicle for cargos transportation
*JT/T 711-2016 Limits and measurement methods of fuel consumption for commercial vehicle for passenger transportation
*JC 987-2005 Fittings for water closet flush tank
*SY/T 5579.1-2008 Reservoir description method—Part 1:General provisions
*SY/T 5112-2008 Specification for drilling and production hoisting equipment
*SY/T 5247-2008 Recommended handling methods of downhole problems in driling
*YDC 014-2008 Technical Specification of Base Station Subsystem (BSS) for 800MHz CDMA 1X Digital Cellular Mobile Telecommunication Network
*TB/T 1436.2-2008 Lubricating oil filter for diesel locomotive Part2: Test methods
Code of China
Standard
JGJ 36-2016  Code for design of dormitory building (English Version)
Standard No.JGJ 36-2016
Statusvalid
LanguageEnglish
File FormatPDF
Word Count13500 words
Price(USD)330.0
Implemented on2017-6-1
Deliveryvia email in 1 business day
Detail of JGJ 36-2016
Standard No.
JGJ 36-2016
English Name
Code for design of dormitory building
Chinese Name
宿舍建筑设计规范
Chinese Classification
Professional Classification
JG
ICS Classification
Issued by
MOHURD
Issued on
2016-12-15
Implemented on
2017-6-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
JGJ 36-2005 Code for Design of Dormitory Building
Language
English
File Format
PDF
Word Count
13500 words
Price(USD)
330.0
Keywords
JGJ 36-2016, JGJ/T 36-2016, JGJT 36-2016, JGJ36-2016, JGJ 36, JGJ36, JGJ/T36-2016, JGJ/T 36, JGJ/T36, JGJT36-2016, JGJT 36, JGJT36
Introduction of JGJ 36-2016
Codeofchina.com is in charge of this English translation. In case of any doubt about the contents of English translation, the Chinese original shall be considered authoritative. In accordance with "Notice on Printing the Development and Revision Plan on Engineering Construction Standards and Codes in 2014" (Jian Biao [2013] No. 169) of the Ministry of Housing and Urban-Rural Development, the specification drafting group, through extensive investigation and by reference to relevant international and foreign advanced standards, has revised this code by earnestly summarizing practical experience and widely soliciting opinions. The main technical contents of this code are as follows: 1. General Provisions; 2. Terms; 3. Site and General Layout; 4. Architectural Design; 5. Fire Protection and Safe Evacuation; 6. Indoor Environment; 7. Building equipment. The following technical deviations have been made in this code: 1. terms are modified and added; 2. foundation and outdoor environment are refined, and safety index is added; 3. classification and usable area standard of some bedrooms are modified and added; 4. the standard of appliance configuration in affiliating room is modified; 5. the clause of fire protection and safe evacuation is added. Provisions printed in bold type in this code are mandatory ones and must be implemented strictly. The Ministry of Housing and Urban-Rural Development is in charge of the administration of this code and the explanation of the compulsory provisions, and the China Institute of Building Standard Design & Research is responsible for the explanation of specific technical contents. During the process of implementing this specification, the relevant opinions and advice, whenever necessary, can be posted or passed on to China Institute of Building Standard Design & Research (Address: No.2 Building, No.9 Zhuyu International Commercial Center, Shouti South Road, Haidian District, Beijing, 100048).   Contents Foreword I 1 General Provisions 1 2 Terms 1 3 Site and General Layout 2 3.1 Site 2 3.2 General Layout 2 4 Architectural Design 3 4.1 General Requirements 3 4.2 Bedroom 4 4.3 Affiliating Room 5 4.4 Storey Height and Net Storey Height 7 4.5 Stairs and Elevator 7 4.6 Door, Window and Balcony 8 5 Fire Protection and Safe Evacuation 9 5.1 Fire Protection 9 5.2 Safe Evacuation 9 6 Indoor Environment 10 6.1 Natural Ventilation and Daylighting 10 6.2 Sound Insulation and Noise Reduction 11 6.3 Energy Efficiency 12 6.4 Indoor Air Quality 12 7 Building Equipment 13 7.1 Water Supply and Drainage 13 7.2 Heating, Ventilating and Air-conditioning 13 7.3 Building Electricity 14 Explanation of Wording in this Code 16 List of Quoted Standards 17 Code for Design of Dormitory Building 1 General Provisions 1.0.1 This standard is formulated with a view to implementing the national technical and economic policies in the design of dormitory building and making the design to be of usability, economy, green, aesthetic and high quality. 1.0.2 This code is applicable to design of newly constructed, renovated and extended dormitory building. 1.0.3 The design of dormitory building shall meet the requirements of the local urban and rural planning, the local climate and geographical conditions, and the social, economic and cultural development level. 1.0.4 The design of dormitory building shall not only meet the requirements of this code, but also meet those specified in the relevant national current standards of China. 2 Terms 2.0.1 dormitory residential buildings that are centrally managed and used by single person 2.0.2 bedroom, habitable room rooms for the occupants to sleep, study, and rest 2.0.3 lavatory, bathroom rooms for the occupants to urinate and defecate, bath, wash up and other activities. 2.0.4 public toilet public rooms for the occupants to urinate and defecate, wash hand 2.0.5 public washroom public rooms for the occupants to wash up, wash clothes and other activities 2.0.6 activity room public rooms for receiving, entertainment, small gatherings and other activities of the occupants 2.0.7 usable area the actual area in use of a room, excluding the area of walls, columns and other structural structures and insulation layer. 2.0.8 balcony the space, attached to the external walls of buildings, with a railing or balustrade, for the occupants to conduct outdoor activities, drying clothes and other activities 2.0.9 corridor the space for horizontal public traffic inside a building 2.0.10 store space the fixed space for goods storage (for example: wall cabinet, wall cupboard, special store room, etc.) 2.0.11 public kitchen the cooking room for food processing and cooking and shared by the occupants 3 Site and General Layout 3.1 Site 3.1.1 Dormitory shall not be built on the sites prone to serious geological hazards. 3.1.2 Dormitory site should be under sunshine conditions, daylighting and good ventilation. 3.1.3 The relative flat site and difficult of water accumulation should be selected for dormitory. 3.1.4 The dormitory shall be able to avoid the influence of noise and pollution sources, and shall meet the requirements of national current standards on health protection. 3.2 General Layout 3.2.1 The dormitory should have favorable outdoor environment. 3.2.2 The site design of dormitory shall be carried out, and there shall have perfect drainage facilities. 3.2.3 Dormitory building should be close to work and study place. It should be close to public canteen, commercial network, public bath and other supporting service facilities, and its service radius should not exceed 250m. 3.2.4 The main entrances and exits of dormitory building shall be provided with personnel distribution center, and the per capita area index shall not be less than 0.20m2. There should be centralized green space near the dormitory. 3.2.5 Distribution center and centralized green space should be simultaneously served as emergency shelter, which may be supplied with spare power source, water source, toilet/bath or drainage and other necessity facilities. 3.2.6 There shall be reasonable streamline design of personnel, non-motor vehicles and motor vehicles, so as to avoid motor vehicles passing through the dormitory area. 3.2.7 There shall be outdoor activity space and bicycle storage place near the dormitory; parking space for motor vehicles should be provided in the dormitory area, and parking spaces and charging facilities for electric cars may be provided or reserved. 3.2.8 The room interval of dormitory building shall meet the requirements of current national standards on fire protection and daylighting, and shall meet the relevant requirements of urban planning. 3.2.9 Accessible facilities shall be provided for public traffic space, foot path in the dormitory area and exits and entrances of dormitory, which shall comply with the relevant requirements of the current national standard Codes for Accessibility Design (GB 50763). 3.2.10 Identification system shall be installed in the dormitory area. 4 Architectural Design 4.1 General Requirements 4.1.1 The plane layout of dormitory may be in gallery type and unit type layout, and the horizontal traffic streamline of middle corridor type dormitory should not be too long. 4.1.2 Caretaker room, activity room and clothes drying space shall be set in each dormitory building. The arrangement of public rooms shall have no influence bedrooms. 4.1.3 Dormitory building shall meet the requirement of natural daylighting and air conditioning. Half and above bedrooms of dormitory building shall be good orientation. 4.1.4 The setting requirements of accessible bedrooms and accessible facilities of dormitory shall meet the relevant requirements of the current national standard Codes for Accessibility Design (GB 50763). 4.1.5 When dormitory with open and transparent side corridor and outside stairway, anti-rain facilities and anti-skid measures of floors shall be provided. Antiskid design of exit and entrance and platform, public corridor, elevator hall, bathroom, washroom, toilet shall meet the requirements of the current professional standard Technical Specification for Slip Resistance of Building Floor (JGJ/T 331). 4.1.6 When heating and air conditioning equipment are set up, the equipment foundation, shelf board and other building elements shall be integrated with the building. 4.1.7 When public exit and entrance of dormitory is located under the balcony, side corridor and open stair platform, safety protective measures to prevent person injured by falling objects shall be taken. 4.1.8 Design of dormitory building shall make use of industrialized construction technology, and shall comply with the relevant requirements of the current national standard Standard for Modular Coordination of Building (GB/T 50002). 4.2 Bedroom 4.2.1 Bedrooms of dormitory shall be classified into five types according to their service requirements, the usable area per capita of each type of bedroom should not be less than those specified in Table 4.2.1. Table 4.2.1 Type and Related Indexes of Bedroom Type Type 1 Type 2 Type 3 Type 4 Type 5 Number of occupants (count) per room 1 2 3 - 4 6 ≥8 Usable area per capita (m2/person) Bed, loft bed 16 8 6 — — Bunk bed — — — 5 4 Store space Wardrobe, wall cabinet, wall cupboard and bookshelf Note 1: The area in this table excluding the area of lavatory and balcony of bedroom; Note 2: The occupants of Type 5 dormitory should be 8 persons, and should not exceed 16 persons; Note 3: The area of bedroom for the disabled should be properly increased, and the occupants should not exceed 4 persons; wheelchair turning space with diameter not less than 1.5m shall be provided in the bedroom. 4.2.2 The arrangement of beds in bedroom shall meet the following requirements: 1 The distance between the long sides of two beds shall not be less than 0.60m, and shall not be less than 0.80m in accessible bedroom; 2 The distance between two bed heads shall not be less than 0.10m; 3 The width of walkway between two rows of beds, or between bed and wall, shall not be less than 1.20m, and wheelchair turning space shall be provided in the bedroom of the disabled; 4 The position of heating facilities shall be reasonably arranged in bedroom of heating area. 4.2.3 Store space shall be provided in bedroom, and net store space per capita should be 0.50m3 to 0.80m3; the net depth of clothes store space should not be less than 0.55m.When fixed luggage rack is provided, the clearance length of each lattice should not be less than 0.80m, the width should not be less than 0.60m, and the height should not be less than 0.45m. For the dimensions of bookshelf, the net depth shall not be less than 0.25m, and the net height of each lattice shall not be less than 0.35m. 4.2.4 For the wall surface adjacent to public washroom, public toilet, lavatory and other wet rooms of bedroom, damp-proof treatment for upstream face of adjacent wall shall be carried out. 4.2.5 Bedroom shall not be located basement. 4.2.6 Dormitory bedrooms of elementary and secondary schools shall not be located at semi-basement, and other dormitory bedrooms should not be located at semi-basement. 4.2.7 At least one accessible bedroom shall be set on the main entrance floor of dormitory building, and accessible bathroom should be set.
Contents of JGJ 36-2016
Foreword I 1 General Provisions 2 Terms 3 Site and General Layout 3.1 Site 3.2 General Layout 4 Architectural Design 4.1 General Requirements 4.2 Bedroom 4.3 Affiliating Room 4.4 Storey Height and Net Storey Height 4.5 Stairs and Elevator 4.6 Door, Window and Balcony 5 Fire Protection and Safe Evacuation 5.1 Fire Protection 5.2 Safe Evacuation 6 Indoor Environment 6.1 Natural Ventilation and Daylighting 6.2 Sound Insulation and Noise Reduction 6.3 Energy Efficiency 6.4 Indoor Air Quality 7 Building Equipment 7.1 Water Supply and Drainage 7.2 Heating, Ventilating and Air-conditioning 7.3 Building Electricity Explanation of Wording in this Code List of Quoted Standards
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JGJ 36-2016, JGJ/T 36-2016, JGJT 36-2016, JGJ36-2016, JGJ 36, JGJ36, JGJ/T36-2016, JGJ/T 36, JGJ/T36, JGJT36-2016, JGJT 36, JGJT36