Position: Chinese Standard in English/JGJ 66-1991
JGJ 66-1991   Code for design of museums (English Version)
Standard No.: JGJ 66-1991 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 6000 words Translation Price(USD):150.0 remind me the price change

Email:

Implemented on:1991-8-1 Delivery: via email in 1 business day

→ → →

,2016-2-1,1991-8-1,14113729186902BAF93DCDA5B2496
Standard No.: JGJ 66-1991
English Name: Code for design of museums
Chinese Name: 博物馆建筑设计规范
Chinese Classification: P33    Residential and public building engineering
Professional Classification: JG    Professional Standard - Building
ICS Classification: 91.040.10 91.040.10    Public buildings 91.040.10
Source Content Issued by: MOC
Issued on: 1991-5-18
Implemented on: 1991-8-1
Status: superseded
Superseded by:JGJ 66-2015 Code for Design of Museum Building
Superseded on:2016-2-1
Target Language: English
File Format: PDF
Word Count: 6000 words
Translation Price(USD): 150.0
Delivery: via email in 1 business day
1 General Provisions 1.1.0.1 In order to adapt to requirements of museum construction and guarantee building design of museums to meet basic requirements for applicability, safety and sanitation, this code is prepared. 1.1.0.2 This code is applicable to new construction and extension designs for museums of social history and natural history. Renovation design and design of other museums may be carried out by reference to relevant provisions of this code. 1.1.0.3 Museums are classified into large, medium and small sizes. Generally, the large size (with building scale greater than 10000m2) is applicable to museums directly subordinate to ministries and commissions under central government and those of all provinces, autonomous regions, municipalities; the medium size (with building scale being 4000~10000m2) is applicable to museums directly subordinate to systematic provincial departments (bureaus) and those of provincially administered municipalities (territories); the small size (with building scale less than 4000m2) is applicable to museums directly subordinate to bureaus of all systematic municipalities (territories) and counties (county-level cities) and those of all counties (county-level cities). Note: building scale only refers to area sum for business and auxiliary buildings of museum, excluding the area of residential buildings of employees. 1.1.0.4 Fire resistance grade of buildings in collection reservoir zone and display zone shall not be lower than 2. Service life of large and medium museums shall not be less than 100 years and that of small ones shall not be less than 50 years. 1.1.0.5 Museum buildings must meet the requirements of planning layout for urban culture buildings and shall reflect the advanced level of architecture art, science and technology and cultural development in location area. 1.1.0.6 Design of museum buildings must be matched with the complete process design and meet the basic functions of collection & storage, scientific research and display & exhibition of collections and shall be arranged with matched service facilities for the audience. 1.1.0.7 Renovation design of historic building must meet all laws and regulations of cultural relic and keep the original building style and shall meet the safety requirements for fire protection and burglary prevention. The collection warehouse should be newly-built. 1.1.0.8 Design of museum buildings shall meet not only the requirements stipulated in this code but also the requirements of current "Code for Design of Civil Buildings" (JGJ 37) and relevant design standards and specifications issued by the nation and specialized departments. 2 Site and General Plan
Contents 1 General Provisions 2 Site and General Plan 3 Building Design 3.1 General Requirements 3.2 Collection Reservoir Zone 3.3 Display Zone 3.4 Technology and Office Buildings 4 Collection Protection 4.1 General Requirements 4.2 Temperature and Humidity Requirements 4.3 Damp Proof and Water Proof 4.4 Illumination Requirements 4.5 Smoke Dust Proof and Harmful Gas Proof 4.6 Insect Proof and Rat Proof 4.7 Burglary Prevention 5 Fire Protection 5.1 Building Fire Protection 5.2 Safe Evacuation 5.3 Fire Protection Facilities 6 Building Equipment 6.1 Water Supply and Drainage 6.2 Heating, Ventilation and Air Conditioning 6.3 Electricity Appendix I Explanation of Nouns Appendix II Explanation of Wording Additional Explanation
Code of China
Standard
JGJ 66-1991  Code for design of museums (English Version)
Standard No.JGJ 66-1991
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)150.0
Implemented on1991-8-1
Deliveryvia email in 1 business day
Detail of JGJ 66-1991
Standard No.
JGJ 66-1991
English Name
Code for design of museums
Chinese Name
博物馆建筑设计规范
Chinese Classification
P33
Professional Classification
JG
ICS Classification
Issued by
MOC
Issued on
1991-5-18
Implemented on
1991-8-1
Status
superseded
Superseded by
JGJ 66-2015 Code for Design of Museum Building
Superseded on
2016-2-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
150.0
Keywords
JGJ 66-1991, JGJ/T 66-1991, JGJT 66-1991, JGJ66-1991, JGJ 66, JGJ66, JGJ/T66-1991, JGJ/T 66, JGJ/T66, JGJT66-1991, JGJT 66, JGJT66
Introduction of JGJ 66-1991
1 General Provisions 1.1.0.1 In order to adapt to requirements of museum construction and guarantee building design of museums to meet basic requirements for applicability, safety and sanitation, this code is prepared. 1.1.0.2 This code is applicable to new construction and extension designs for museums of social history and natural history. Renovation design and design of other museums may be carried out by reference to relevant provisions of this code. 1.1.0.3 Museums are classified into large, medium and small sizes. Generally, the large size (with building scale greater than 10000m2) is applicable to museums directly subordinate to ministries and commissions under central government and those of all provinces, autonomous regions, municipalities; the medium size (with building scale being 4000~10000m2) is applicable to museums directly subordinate to systematic provincial departments (bureaus) and those of provincially administered municipalities (territories); the small size (with building scale less than 4000m2) is applicable to museums directly subordinate to bureaus of all systematic municipalities (territories) and counties (county-level cities) and those of all counties (county-level cities). Note: building scale only refers to area sum for business and auxiliary buildings of museum, excluding the area of residential buildings of employees. 1.1.0.4 Fire resistance grade of buildings in collection reservoir zone and display zone shall not be lower than 2. Service life of large and medium museums shall not be less than 100 years and that of small ones shall not be less than 50 years. 1.1.0.5 Museum buildings must meet the requirements of planning layout for urban culture buildings and shall reflect the advanced level of architecture art, science and technology and cultural development in location area. 1.1.0.6 Design of museum buildings must be matched with the complete process design and meet the basic functions of collection & storage, scientific research and display & exhibition of collections and shall be arranged with matched service facilities for the audience. 1.1.0.7 Renovation design of historic building must meet all laws and regulations of cultural relic and keep the original building style and shall meet the safety requirements for fire protection and burglary prevention. The collection warehouse should be newly-built. 1.1.0.8 Design of museum buildings shall meet not only the requirements stipulated in this code but also the requirements of current "Code for Design of Civil Buildings" (JGJ 37) and relevant design standards and specifications issued by the nation and specialized departments. 2 Site and General Plan
Contents of JGJ 66-1991
Contents 1 General Provisions 2 Site and General Plan 3 Building Design 3.1 General Requirements 3.2 Collection Reservoir Zone 3.3 Display Zone 3.4 Technology and Office Buildings 4 Collection Protection 4.1 General Requirements 4.2 Temperature and Humidity Requirements 4.3 Damp Proof and Water Proof 4.4 Illumination Requirements 4.5 Smoke Dust Proof and Harmful Gas Proof 4.6 Insect Proof and Rat Proof 4.7 Burglary Prevention 5 Fire Protection 5.1 Building Fire Protection 5.2 Safe Evacuation 5.3 Fire Protection Facilities 6 Building Equipment 6.1 Water Supply and Drainage 6.2 Heating, Ventilation and Air Conditioning 6.3 Electricity Appendix I Explanation of Nouns Appendix II Explanation of Wording Additional Explanation
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JGJ 66-1991, JGJ/T 66-1991, JGJT 66-1991, JGJ66-1991, JGJ 66, JGJ66, JGJ/T66-1991, JGJ/T 66, JGJ/T66, JGJT66-1991, JGJT 66, JGJT66