2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JJF(闽)1068-2015
JJF(闽)1068-2015   Calibration Specification for Digital Air Flow Hood (English Version)
Standard No.: JJF(闽)1068-2015 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 12000 words Translation Price(USD):320.0 remind me the price change

Email:

Implemented on:2015-5-1 Delivery: via email in 1 business day

→ → →

,,2015-5-1,279C9E01015E1A641441091691021
Standard No.: JJF(闽)1068-2015
English Name: Calibration Specification for Digital Air Flow Hood
Chinese Name: 数字风量罩校准规范
Professional Classification: JJ    Metering
Source Content Issued by: Fujian Provincial Quality and Technology Supervision Bureau
Issued on: 2015-03-01
Implemented on: 2015-5-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 12000 words
Translation Price(USD): 320.0
Delivery: via email in 1 business day
Calibration specification for digital air flow hood 1 Scope This specification is applicable to the calibration of digital air flow hood (hereinafter referred to as air flow hood) with measuring range of (30 ~ 5000) m3/h. 2 Normative references The normative references of this specification are as follows: JJG 431-1986 Verification regulation of portable 3-cup anemometer Type DEM6 JJG 515-1987 Verification regulation of portable induction anemometer JJG 613-1989 Verification regulation of contact anemorumbometer JJF 1001 -2011 General terms in metrology and their definitions 3 Terms 3.1 air flow the amount of air in circulation per unit time, in m3/h 3.2 digital air flow hood an instrument that collects air flow to the speed equalizer on the base by using the air flow collecting hood, calculates the air flow value after measuring the air speed change value on the equalizer and the ventilation cross-sectional area of the base, and displays the air flow value directly through the digital display panel 3.3 air flow calibration fitting line the fitting line used to depict approximately or analogize the functional relationship between the measurement results of the air flow hood and the coordinates represented by the discrete point group of the air flow characteristic value on the plane 4 General Air flow hood is mainly used for air flow measurement. The working principle of the air flow hood is: measure the air speed by the air flow pressure sensor or thermal sensor on the end face of the base obtain, calculate the average value of the wind speed, and multiply the average value and the ventilation cross-sectional area of the base to get the air flow value. The air flow hood generally consists of a digital display panel, a nylon air hood, handles and a base (as shown in Figure 1). Figure 1 Schematic diagram for air flow hood 5 Metrological characteristics 5.1 Measurement error The air flow measurement error of the air flow hood is generally ± (3% ~ 10%) of the measuring range. 5.2 Appearance 5.2.1 All parts shall be installed correctly and firmly, the movable parts shall be flexible and reliable, and the nylon air hood shall be free of damage and leakage. 5.2.2 A nameplate shall be installed at an appropriate position, which should contain the following information: instrument name, model, end-of-manufacturing number, measurement range, measurement error, manufacturer or trademark, end-of-manufacturing date, etc. 5.2.3 The figures on the display panel shall be clear and complete, and the power supply interface, if any, shall be free of corrosion. 6 Calibration conditions 6.1 Environmental conditions a) Ambient temperature: (20 ± 5)°C; b) Relative humidity: (30% ~ 85%) RH; c) Atmospheric pressure: (950 ~ 1060) hPa.
Introduction ii 1 Scope 2 Normative references 3 Terms 4 General 5 Metrological characteristics 5.1 Measurement error 5.2 Appearance 6 Calibration conditions 6.1 Environmental conditions 6.2 Power supply conditions 6.3 Air flow standard device 6.4 Other equipment 7 Calibration items and methods 7.1 Calibration items 7.2 Pre-calibration inspection 7.3 Calibration methods 8 Expression of calibration results 9 Re-calibration interval Annex A Example of inside page format for air flow hood calibration certificate Annex B Example of original record format for air flow hood calibration Annex C Example 1 of uncertainty evaluation Annex D Example 2 of uncertainty evaluation Annex E Calculation of the standard air flow value Annex F Fitting line equation and fitting line plot of indication - actual air flow value
Referred in JJF(闽)1068-2015:
*JJG 431-1986 Portable 3-Cup Anemometer Type DEM6
*JJG 515-1987 Portable Induction Anemometer
*JJG 613-1989 Contact Anemorumbometer
*JJF 1001-2011 General Terms in Metrology and Their Definitions
Code of China
Standard
JJF(闽)1068-2015  Calibration Specification for Digital Air Flow Hood (English Version)
Standard No.JJF(闽)1068-2015
Statusvalid
LanguageEnglish
File FormatPDF
Word Count12000 words
Price(USD)320.0
Implemented on2015-5-1
Deliveryvia email in 1 business day
Detail of JJF(闽)1068-2015
Standard No.
JJF(闽)1068-2015
English Name
Calibration Specification for Digital Air Flow Hood
Chinese Name
数字风量罩校准规范
Chinese Classification
Professional Classification
JJ
ICS Classification
Issued by
Fujian Provincial Quality and Technology Supervision Bureau
Issued on
2015-03-01
Implemented on
2015-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
12000 words
Price(USD)
320.0
Keywords
JJF(闽)1068-2015, , JJF(闽)1068-2015, JJF(闽)1068,
Introduction of JJF(闽)1068-2015
Calibration specification for digital air flow hood 1 Scope This specification is applicable to the calibration of digital air flow hood (hereinafter referred to as air flow hood) with measuring range of (30 ~ 5000) m3/h. 2 Normative references The normative references of this specification are as follows: JJG 431-1986 Verification regulation of portable 3-cup anemometer Type DEM6 JJG 515-1987 Verification regulation of portable induction anemometer JJG 613-1989 Verification regulation of contact anemorumbometer JJF 1001 -2011 General terms in metrology and their definitions 3 Terms 3.1 air flow the amount of air in circulation per unit time, in m3/h 3.2 digital air flow hood an instrument that collects air flow to the speed equalizer on the base by using the air flow collecting hood, calculates the air flow value after measuring the air speed change value on the equalizer and the ventilation cross-sectional area of the base, and displays the air flow value directly through the digital display panel 3.3 air flow calibration fitting line the fitting line used to depict approximately or analogize the functional relationship between the measurement results of the air flow hood and the coordinates represented by the discrete point group of the air flow characteristic value on the plane 4 General Air flow hood is mainly used for air flow measurement. The working principle of the air flow hood is: measure the air speed by the air flow pressure sensor or thermal sensor on the end face of the base obtain, calculate the average value of the wind speed, and multiply the average value and the ventilation cross-sectional area of the base to get the air flow value. The air flow hood generally consists of a digital display panel, a nylon air hood, handles and a base (as shown in Figure 1). Figure 1 Schematic diagram for air flow hood 5 Metrological characteristics 5.1 Measurement error The air flow measurement error of the air flow hood is generally ± (3% ~ 10%) of the measuring range. 5.2 Appearance 5.2.1 All parts shall be installed correctly and firmly, the movable parts shall be flexible and reliable, and the nylon air hood shall be free of damage and leakage. 5.2.2 A nameplate shall be installed at an appropriate position, which should contain the following information: instrument name, model, end-of-manufacturing number, measurement range, measurement error, manufacturer or trademark, end-of-manufacturing date, etc. 5.2.3 The figures on the display panel shall be clear and complete, and the power supply interface, if any, shall be free of corrosion. 6 Calibration conditions 6.1 Environmental conditions a) Ambient temperature: (20 ± 5)°C; b) Relative humidity: (30% ~ 85%) RH; c) Atmospheric pressure: (950 ~ 1060) hPa.
Contents of JJF(闽)1068-2015
Introduction ii 1 Scope 2 Normative references 3 Terms 4 General 5 Metrological characteristics 5.1 Measurement error 5.2 Appearance 6 Calibration conditions 6.1 Environmental conditions 6.2 Power supply conditions 6.3 Air flow standard device 6.4 Other equipment 7 Calibration items and methods 7.1 Calibration items 7.2 Pre-calibration inspection 7.3 Calibration methods 8 Expression of calibration results 9 Re-calibration interval Annex A Example of inside page format for air flow hood calibration certificate Annex B Example of original record format for air flow hood calibration Annex C Example 1 of uncertainty evaluation Annex D Example 2 of uncertainty evaluation Annex E Calculation of the standard air flow value Annex F Fitting line equation and fitting line plot of indication - actual air flow value
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JJF(闽)1068-2015, , JJF(闽)1068-2015, JJF(闽)1068,