2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/MT 818.2-2009
MT 818.2-2009   Cables for coal mine - Part 2: Flexible cables for use with coal cutters of rated voltages up to andincluding 1.9/3.3kV (English Version)
Standard No.: MT 818.2-2009 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 3000 words Translation Price(USD):194.0 remind me the price change

Email:

Implemented on:2010-7-1 Delivery: via email in 1 business day

→ → →

,,2010-7-1,1411376551823352A04D75469D1FE
Standard No.: MT 818.2-2009
English Name: Cables for coal mine - Part 2: Flexible cables for use with coal cutters of rated voltages up to andincluding 1.9/3.3kV
Chinese Name: 煤矿用电缆 第2部分:额定电压1.9/3.3kV及以下采煤机软电缆
Chinese Classification: K13    Cable and its accessory
Professional Classification: MT    Professional Standard - Coal
ICS Classification: 29.060.20 29.060.20    Cables 29.060.20
Source Content Issued by: AQSIQ
Issued on: 2009-12-11
Implemented on: 2010-7-1
Status: valid
Superseding:MT 818.2-1999
Target Language: English
File Format: PDF
Word Count: 3000 words
Translation Price(USD): 194.0
Delivery: via email in 1 business day
Cables for Coal Mine-Part 2: Flexible Cables for Use with Coal Cutters of Rated Voltages Up to and Including 1.9/3.3 kV 1 Scope This Part of MT 818 specifies the product classification, naming, technical requirements, test methods and inspection rules of flexible cables for use with coal cutters of rated voltages up to and including 1.9/3.3 kV (hereinafter referred to as cable). This Part is applicable to the copper-core rubber sheathed flexible cables for use with coal cutters and similar equipments of rated voltages up to and including 1.9/3.3 kV. 2 Normative References The following standards contain provisions which, through reference in this Part of MT 818, constitute provisions of this Part. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties to agreements based on this Part are encouraged to investigate the possibility of applying the most recent editions of the standards. For undated references, the latest edition of the normative document referred to applies. GB/T 7594.7-1987 Rubber insulation and sheath of electric cables and wires-Part 7:Heavy duty flame-retardant rubber sheath 65 Centigrade (neq IEC 245) GB/T 7594.8-1987 Rubber insulation and sheath of electric cables and wires-Part 8: Rubber sheath 90 Centigrade (neq IEC 245) MT 818.1-2009 Cables for coal mine—Part 1: General rules for movable flexible cables 3 Product Classification and Naming 3.1 Types 3.1.1 Cable models are detailed in Table 1. Table 1 Cable Models Model Name Application Structure Type A Type B MC-0.38/0.66 Rubber-sheathed flexible cables for coal cutters Power supply connection for the coal cutters and similar equipments of rated voltages up to and including 0.38/0.66 kV. √ — MCP-0.38/0.66 Screening rubber-sheathed flexible cables for coal cutters Power supply connection for the coal cutters and similar equipments of rated voltages up to and including 0.38/0.66 kV. √ — MCP-0.66/1.14 Screening rubber-sheathed flexible cables for coal cutters Power supply connection for the coal cutters and similar equipments of rated voltages up to and including 0.66/l.14 kV. √ √ MCP-1.9/3.3 Screening rubber-sheathed flexible cables for coal cutters Power supply connection for the coal cutters and similar equipments of rated voltages up to and including 1.9/3.3 kV √ √ 3.1.2 As for the cables of rated voltage 0.38/0.66 KV, Type A structure as shown in Figure 1 shall be adopted; as for the cables of rated voltages up to and including 0.66/1.14 kV, Type A or Type B structure as shown in Figure 1 shall be adopted. l——Power-core conductor; 2——Earth-wire-core conductor and semiconductive layer (extruded insulating layer of MC type cable); 3——Control core conductor; 4——Insulation; 5——Power-core semiconductive screening layer (no screening layer for MC type cables); 6——Outer sheath; 7——Inner sheath; 8——Strengthening layer.
Referred in MT 818.2-2009:
*GB/T 7594.7-1987 Rubber insulation and sheath of electric cables and wires. Part 7: Heavy duty flame-retardant rubber sheath 65 Centigrade
*GB/T 7594.8-1987 Rubber insulation and sheath of electric cables and wires. Part 8: Rubber sheath 90 Centigrade
*MT 818.1-2009 Cables for coal mine - Part 1: General rules for movable flexible cables
MT 818.2-2009 is referred in:
*GB/T 35060.1-2018 General specification of shearer--Part 1: Complete machine
*MT 818.1-2009 Cables for coal mine - Part 1: General rules for movable flexible cables
Code of China
Standard
MT 818.2-2009  Cables for coal mine - Part 2: Flexible cables for use with coal cutters of rated voltages up to andincluding 1.9/3.3kV (English Version)
Standard No.MT 818.2-2009
Statusvalid
LanguageEnglish
File FormatPDF
Word Count3000 words
Price(USD)194.0
Implemented on2010-7-1
Deliveryvia email in 1 business day
Detail of MT 818.2-2009
Standard No.
MT 818.2-2009
English Name
Cables for coal mine - Part 2: Flexible cables for use with coal cutters of rated voltages up to andincluding 1.9/3.3kV
Chinese Name
煤矿用电缆 第2部分:额定电压1.9/3.3kV及以下采煤机软电缆
Chinese Classification
K13
Professional Classification
MT
ICS Classification
Issued by
AQSIQ
Issued on
2009-12-11
Implemented on
2010-7-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
MT 818.2-1999
Language
English
File Format
PDF
Word Count
3000 words
Price(USD)
194.0
Keywords
MT 818.2-2009, MT/T 818.2-2009, MTT 818.2-2009, MT818.2-2009, MT 818.2, MT818.2, MT/T818.2-2009, MT/T 818.2, MT/T818.2, MTT818.2-2009, MTT 818.2, MTT818.2
Introduction of MT 818.2-2009
Cables for Coal Mine-Part 2: Flexible Cables for Use with Coal Cutters of Rated Voltages Up to and Including 1.9/3.3 kV 1 Scope This Part of MT 818 specifies the product classification, naming, technical requirements, test methods and inspection rules of flexible cables for use with coal cutters of rated voltages up to and including 1.9/3.3 kV (hereinafter referred to as cable). This Part is applicable to the copper-core rubber sheathed flexible cables for use with coal cutters and similar equipments of rated voltages up to and including 1.9/3.3 kV. 2 Normative References The following standards contain provisions which, through reference in this Part of MT 818, constitute provisions of this Part. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties to agreements based on this Part are encouraged to investigate the possibility of applying the most recent editions of the standards. For undated references, the latest edition of the normative document referred to applies. GB/T 7594.7-1987 Rubber insulation and sheath of electric cables and wires-Part 7:Heavy duty flame-retardant rubber sheath 65 Centigrade (neq IEC 245) GB/T 7594.8-1987 Rubber insulation and sheath of electric cables and wires-Part 8: Rubber sheath 90 Centigrade (neq IEC 245) MT 818.1-2009 Cables for coal mine—Part 1: General rules for movable flexible cables 3 Product Classification and Naming 3.1 Types 3.1.1 Cable models are detailed in Table 1. Table 1 Cable Models Model Name Application Structure Type A Type B MC-0.38/0.66 Rubber-sheathed flexible cables for coal cutters Power supply connection for the coal cutters and similar equipments of rated voltages up to and including 0.38/0.66 kV. √ — MCP-0.38/0.66 Screening rubber-sheathed flexible cables for coal cutters Power supply connection for the coal cutters and similar equipments of rated voltages up to and including 0.38/0.66 kV. √ — MCP-0.66/1.14 Screening rubber-sheathed flexible cables for coal cutters Power supply connection for the coal cutters and similar equipments of rated voltages up to and including 0.66/l.14 kV. √ √ MCP-1.9/3.3 Screening rubber-sheathed flexible cables for coal cutters Power supply connection for the coal cutters and similar equipments of rated voltages up to and including 1.9/3.3 kV √ √ 3.1.2 As for the cables of rated voltage 0.38/0.66 KV, Type A structure as shown in Figure 1 shall be adopted; as for the cables of rated voltages up to and including 0.66/1.14 kV, Type A or Type B structure as shown in Figure 1 shall be adopted. l——Power-core conductor; 2——Earth-wire-core conductor and semiconductive layer (extruded insulating layer of MC type cable); 3——Control core conductor; 4——Insulation; 5——Power-core semiconductive screening layer (no screening layer for MC type cables); 6——Outer sheath; 7——Inner sheath; 8——Strengthening layer.
Contents of MT 818.2-2009
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
MT 818.2-2009, MT/T 818.2-2009, MTT 818.2-2009, MT818.2-2009, MT 818.2, MT818.2, MT/T818.2-2009, MT/T 818.2, MT/T818.2, MTT818.2-2009, MTT 818.2, MTT818.2