2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/SY/T 6633-2019
SY/T 6633-2019   Guide of emergency alarms for offshore petroleum installations (English Version)
Standard No.: SY/T 6633-2019 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 7500 words Translation Price(USD):225.0 remind me the price change

Email:

Implemented on:2020-5-1 Delivery: via email in 1 business day

→ → →

,,2020-5-1,5F822DB24863084C1575175085430
Standard No.: SY/T 6633-2019
English Name: Guide of emergency alarms for offshore petroleum installations
Chinese Name: 海上石油设施应急报警信号指南
Professional Classification: SY    Professional Standard - Oil & Gas
Source Content Issued by: NEA
Issued on: 2019-11-04
Implemented on: 2020-5-1
Status: valid
Superseding:SY/T 6633-2012 Provision of emergency alarms for offshore petroleum installations
Target Language: English
File Format: PDF
Word Count: 7500 words
Translation Price(USD): 225.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009 Directives for standardization - Part 1: Structure and drafting of standards. This standard replaces SY 6633-2012 Provision of emergency alarms for offshore petroleum installations, and the following main technical changes have been made with respect to SY 6633-2012: ——This standard is changed from a mandatory standard to a voluntary standard; ——The standard is renamed from Provision of emergency alarms for offshore petroleum installations to Guide of emergency alarms for offshore petroleum installations; ——The “Introduction” is added; ——The word "anti-terrorism" is modified as "terrorist activity" in the scope (see clause 1; clause 1 of Edition 2012); ——The “auditory signal” is modified (see Table B.1; Table B.1 of Edition 2012). This standard was proposed by and is under the jurisdiction of the Technical Committee for Standardization of Safety in Petroleum Industry. This standard replaces SY 6633-2012. The previous edition of SY 6633-2012 is as follows: ——SY/T 6633-2005. Introduction SY 6633-2012 Provision of emergency alarms for offshore petroleum installations has contributed to solving the inconsistency of alarm signals for offshore petroleum installations since its promulgation, and has strengthened the ability of offshore operators to identify alarm signals. The description of alarm signals in the original standard is imperfect. In combination with the work requirements of transforming 71 mandatory professional standards in the energy field into voluntary professional standards in the No.4 Announcement of the National Energy Administration in 2017, the standard drafting unit carried out the revision work on SY 6633-2012 Provision of emergency alarms for offshore petroleum installations. The revised SY/T 6633-2019 Guide of emergency alarms for offshore petroleum installations has more guiding significance for setting emergency alarm signals for offshore petroleum installations. Guide of emergency alarms for offshore petroleum installations 1 Scope This standard specifies the emergency alarm signals for offshore petroleum installations in the event of fire, blowout, oil and gas leak, hydrogen sulfide leak, oil spill, man overboard, terrorist activity, platform abandonment and distress at sea. This standard is applicable to offshore petroleum installations such as mobile and fixed platforms, oil and gas production facilities, floating production and storage devices, onshore oil (gas) processing terminals, oil (gas) transportation wharf, beach and alongshore installations, and artificial islands engaged in offshore petroleum exploration and development. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 2893 Safety colours GB 2894 Safety signs and guideline for the use GB 50116 Code for design of automatic fire alarm system No. 25 Decree of the State Administration of work Safety Detailed rules for the administration of offshore oil safety 3 Provisions for signals 3.1 Sign signal Offshore petroleum installations shall be equipped with wind vanes and anemometers, as well as three kind of rectangular warning boards with the words "Hydrogen Sulfide" and "H2S” in green, yellow or red meeting the requirements of the Detailed rules for the administration of offshore oil safety. The font color, size and position of the warning boards shall be set in accordance with GB 2893 and GB 2894. 3.2 Visual signal Types of dangers of offshore petroleum installations and corresponding visual signals (lights) shall meet those specified in Annex A. 3.3 Auditory signal Types of dangers of offshore petroleum installations and corresponding auditory signals shall meet those specified in Annex B. 4 Alarm methods 4.1 Sign alarm On the offshore petroleum installations, a green warning board marked with the word hydrogen sulfide shall be hung if the concentration of hydrogen sulfide in the air is less than 15mg/m3(10ppm), a yellow one if the concentration of hydrogen sulfide in the air is 15mg/m3~30mg/m3(10ppm~20ppm), and a red one if the concentration of hydrogen sulfide in the air is larger than 30mg/m3(20ppm). The warning board shall be set in a conspicuous and visible position. 4.2 Visual alarm The status lights installed in a fixed way at all places of the offshore petroleum installations shall be used to display the required signals which are shown in Annex A. 4.3 Auditory alarm 4.3.1 Alarm shall be capable of being sent through manual alarm button. 4.3.2 The alarm shall be capable of being automatically triggered by a sensor. 4.3.3 The alarm signals in Annex B shall be switched into the public address system. 4.3.4 Other applicable sounds may be used to send the alarm. 4.4 Broadcast alarm 4.4.1 The alarm signal shall be broadcast to the whole offshore petroleum installation by voice through the public address system. 4.4.2 Alarm telephones installed in relevant parts of the offshore petroleum installation shall be switched into the public address system to give voice alarm. 4.4.3 The speaker shall be set in places where the ambient noise is greater than 60dB in accordance with GB 50116, with the broadcasting sound pressure level at the furthest point within the broadcasting scope 1.5dB(A) higher than that of the background noise.
Foreword i Introduction ii 1 Scope 2 Normative references 3 Provisions for signals 3.1 Sign signal 3.2 Visual signal 3.3 Auditory signal 4 Alarm methods 4.1 Sign alarm 4.2 Visual alarm 4.3 Auditory alarm 4.4 Broadcast alarm Annex A (Normative) Visual signals Annex B (Normative) Auditory signals Bibliography
Referred in SY/T 6633-2019:
*GB 2893-2008 Safety colours
*GB 2894-2008 Safety Signs and Guideline for the Use
*GB 50116-2013 Code for design of automatic fire alarm system
*GB/T 95-2002 Plain washers - Product grade C
*GB/T 2664-2009 Mens suits and coats
*GB 4706.1-2005 Household and Similar Electrical Appliances – Safety - Part 1: General Requirements
*GB 17625.1-2022 Electromagnetic compatibility—Limits—Part 1: Limits for harmonic current emissions (equipment input current ≤ 16A per phase)
*GB/T 14048.5-2017 Low-voltage switchgear and controlgear-Part 5-1:Control circuit devices and switching element-Electromechanical control circuit devices
*GB 17625.1-2022 Electromagnetic compatibility—Limits—Part 1: Limits for harmonic current emissions (equipment input current ≤ 16A per phase)
*QB/T 1333-2018 Handbag and Knapsack
*GB 2762-2022 National Food Safety Standard - Maximum Levels of Contaminants in Foods
*GB/T 22849-2014 Knitted T-shirt
*GB 5749-2022 Standards for drinking water quality
*GB 14748-2006 Safety Requirements for Wheeled Child Conveyances
*GB/T 1591-2018 High strength low alloy structural steels
*GB 4943.1-2011 Information technology equipment -Safety - Part 1: General requirements
*GB 2763-2021 National Food Safety Standard-Maximum Residue Limits for Pesticides in Food
Code of China
Standard
SY/T 6633-2019  Guide of emergency alarms for offshore petroleum installations (English Version)
Standard No.SY/T 6633-2019
Statusvalid
LanguageEnglish
File FormatPDF
Word Count7500 words
Price(USD)225.0
Implemented on2020-5-1
Deliveryvia email in 1 business day
Detail of SY/T 6633-2019
Standard No.
SY/T 6633-2019
English Name
Guide of emergency alarms for offshore petroleum installations
Chinese Name
海上石油设施应急报警信号指南
Chinese Classification
Professional Classification
SY
ICS Classification
Issued by
NEA
Issued on
2019-11-04
Implemented on
2020-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
SY/T 6633-2012 Provision of emergency alarms for offshore petroleum installations
Language
English
File Format
PDF
Word Count
7500 words
Price(USD)
225.0
Keywords
SY/T 6633-2019, SY 6633-2019, SYT 6633-2019, SY/T6633-2019, SY/T 6633, SY/T6633, SY6633-2019, SY 6633, SY6633, SYT6633-2019, SYT 6633, SYT6633
Introduction of SY/T 6633-2019
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009 Directives for standardization - Part 1: Structure and drafting of standards. This standard replaces SY 6633-2012 Provision of emergency alarms for offshore petroleum installations, and the following main technical changes have been made with respect to SY 6633-2012: ——This standard is changed from a mandatory standard to a voluntary standard; ——The standard is renamed from Provision of emergency alarms for offshore petroleum installations to Guide of emergency alarms for offshore petroleum installations; ——The “Introduction” is added; ——The word "anti-terrorism" is modified as "terrorist activity" in the scope (see clause 1; clause 1 of Edition 2012); ——The “auditory signal” is modified (see Table B.1; Table B.1 of Edition 2012). This standard was proposed by and is under the jurisdiction of the Technical Committee for Standardization of Safety in Petroleum Industry. This standard replaces SY 6633-2012. The previous edition of SY 6633-2012 is as follows: ——SY/T 6633-2005. Introduction SY 6633-2012 Provision of emergency alarms for offshore petroleum installations has contributed to solving the inconsistency of alarm signals for offshore petroleum installations since its promulgation, and has strengthened the ability of offshore operators to identify alarm signals. The description of alarm signals in the original standard is imperfect. In combination with the work requirements of transforming 71 mandatory professional standards in the energy field into voluntary professional standards in the No.4 Announcement of the National Energy Administration in 2017, the standard drafting unit carried out the revision work on SY 6633-2012 Provision of emergency alarms for offshore petroleum installations. The revised SY/T 6633-2019 Guide of emergency alarms for offshore petroleum installations has more guiding significance for setting emergency alarm signals for offshore petroleum installations. Guide of emergency alarms for offshore petroleum installations 1 Scope This standard specifies the emergency alarm signals for offshore petroleum installations in the event of fire, blowout, oil and gas leak, hydrogen sulfide leak, oil spill, man overboard, terrorist activity, platform abandonment and distress at sea. This standard is applicable to offshore petroleum installations such as mobile and fixed platforms, oil and gas production facilities, floating production and storage devices, onshore oil (gas) processing terminals, oil (gas) transportation wharf, beach and alongshore installations, and artificial islands engaged in offshore petroleum exploration and development. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 2893 Safety colours GB 2894 Safety signs and guideline for the use GB 50116 Code for design of automatic fire alarm system No. 25 Decree of the State Administration of work Safety Detailed rules for the administration of offshore oil safety 3 Provisions for signals 3.1 Sign signal Offshore petroleum installations shall be equipped with wind vanes and anemometers, as well as three kind of rectangular warning boards with the words "Hydrogen Sulfide" and "H2S” in green, yellow or red meeting the requirements of the Detailed rules for the administration of offshore oil safety. The font color, size and position of the warning boards shall be set in accordance with GB 2893 and GB 2894. 3.2 Visual signal Types of dangers of offshore petroleum installations and corresponding visual signals (lights) shall meet those specified in Annex A. 3.3 Auditory signal Types of dangers of offshore petroleum installations and corresponding auditory signals shall meet those specified in Annex B. 4 Alarm methods 4.1 Sign alarm On the offshore petroleum installations, a green warning board marked with the word hydrogen sulfide shall be hung if the concentration of hydrogen sulfide in the air is less than 15mg/m3(10ppm), a yellow one if the concentration of hydrogen sulfide in the air is 15mg/m3~30mg/m3(10ppm~20ppm), and a red one if the concentration of hydrogen sulfide in the air is larger than 30mg/m3(20ppm). The warning board shall be set in a conspicuous and visible position. 4.2 Visual alarm The status lights installed in a fixed way at all places of the offshore petroleum installations shall be used to display the required signals which are shown in Annex A. 4.3 Auditory alarm 4.3.1 Alarm shall be capable of being sent through manual alarm button. 4.3.2 The alarm shall be capable of being automatically triggered by a sensor. 4.3.3 The alarm signals in Annex B shall be switched into the public address system. 4.3.4 Other applicable sounds may be used to send the alarm. 4.4 Broadcast alarm 4.4.1 The alarm signal shall be broadcast to the whole offshore petroleum installation by voice through the public address system. 4.4.2 Alarm telephones installed in relevant parts of the offshore petroleum installation shall be switched into the public address system to give voice alarm. 4.4.3 The speaker shall be set in places where the ambient noise is greater than 60dB in accordance with GB 50116, with the broadcasting sound pressure level at the furthest point within the broadcasting scope 1.5dB(A) higher than that of the background noise.
Contents of SY/T 6633-2019
Foreword i Introduction ii 1 Scope 2 Normative references 3 Provisions for signals 3.1 Sign signal 3.2 Visual signal 3.3 Auditory signal 4 Alarm methods 4.1 Sign alarm 4.2 Visual alarm 4.3 Auditory alarm 4.4 Broadcast alarm Annex A (Normative) Visual signals Annex B (Normative) Auditory signals Bibliography