CJJ/T 241-2016   Technical specification for monitoring and controlling system of urban hfeating (English Version)
Standard No.: CJJ/T 241-2016 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 38500 words Translation Price(USD):1150.0 remind me the price change

Email:

Implemented on:2017-5-1 Delivery: via email in 1 business day

→ → →

,,2017-5-1,B12DA03DEB65082D1481708418538
Standard No.: CJJ/T 241-2016
English Name: Technical specification for monitoring and controlling system of urban hfeating
Chinese Name: 城镇供热监测与调控系统技术规程
Professional Classification: CJ    Professional Standard - Urban Construction
Source Content Issued by: Ministry of Housing and Urban-Rural Construction of the People’s Republic of China
Issued on: 2016-11-15
Implemented on: 2017-5-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 38500 words
Translation Price(USD): 1150.0
Delivery: via email in 1 business day
CJJ/T 241-2016 Technical specification for monitoring and controlling system of urban heating 1 General provisions 1.0.1 This specification is formulated in order to standardize the monitoring and control technology of urban heating system, ensure the safe, economic, energy-saving and environmental protection operation of urban heating system, and improve the operation and management level of urban heating system. 1.0.2 This specification is applicable to the design, construction, commissioning & debugging, acceptance, operation and maintenance of urban heating monitoring and controlling system. 1.0.3 The monitoring and control of urban heating system shall not only conform to this specification, but also conform to the current relevant national standards. 2 Terms 2.0.1 monitoring and controlling system software system and hardware facilities that collect, monitor, regulate, and control the main parameters and equipment operating state of various components of the heating system (including heating source outlets, pipe networks, heating stations, and other key parts) 2.0.2 monitoring center monitoring and controlling core hub that collects, processes, stores, transmits, retrieves, and displays information uploaded by local monitoring and controlling stations according to certain application purposes and rules, and issues monitoring instructions to each local monitoring and controlling station 2.0.3 local monitoring and controlling station system to realize local data acquisition, monitoring, control and communication 2.0.4 communication protocol rules and agreements that must be followed by both entities to complete communication or service 2.0.5 control strategy different control rules or countermeasures adopted to achieve control purposes 2.0.6 work station information processing system composed of computer, corresponding external equipment and application software 2.0.7 engineer station human-computer communication equipment between maintenance engineers and monitoring systems, which is used for debugging, modifying programs, and may also have the function of an operator station 2.0.8 operator station human-computer communication equipment between the on-duty personnel and the monitoring system, which is used for monitoring and control 3 Base requirements 3.0.1 The monitoring and controlling system of urban heating shall include monitoring center, communication network and local monitoring and controlling station. 3.0.2 The setting of monitoring and controlling system shall meet the requirements of operation and management. 3.0.3 The units and effective digits of monitoring data shall be unified. 3.0.4 The network security of the monitoring and controlling system shall comply with the following requirements: 1 The communication network of the monitoring center shall take security isolation measures, and the network exit shall be equipped with hardware firewall; 2 The communication network between monitoring center and key local monitoring and controlling station shall adopt redundant design and set up standby channel; 3 The communication network of the monitoring center shall identify and manage the system administrators and operators at different levels, and audit the operation of the system administrators.   3.0.5 The monitoring and controlling system of the newly-built heating project shall be designed, constructed and debugged simultaneously with the main heating project. 3.0.6 The password use and management of urban heating monitoring and controlling system shall comply with the national password administration regulations. 4 Monitoring center 4.1 General requirements 4.1.1 The monitoring center shall be set up according to factors such as heating scale and management need. 4.1.2 The setting of the computer room of the monitoring center shall comply with relevant requirements of the current national standard GB 50174 Code for design of electronic information system room. 4.2 Functions 4.2.1 The monitoring center shall have the following functions: 1 Operation monitoring; 2 Scheduling management; 3 Energy consumption management; 4 Fault diagnosis and alarm processing; 5 Data storage, statistics and analysis; 6 Centralized display. 4.2.2 The monitoring operation module shall have the following functions: 1 Display the process flow and operation parameters; 2 Monitor the operating state of the local monitoring and controlling station in real time; 3 Receive and record the alarm information of local monitoring and controlling station in real time, and form an alarm log; 4 Support multi-level authority management;
Foreword i 1 General provisions 2 Terms 3 Base requirements 4 Monitoring center 4.1 General requirements 4.2 Functions 4.3 Configuration 5 Local monitoring and controlling station 5.1 General requirements 5.2 Heating source plant 5.3 Booster pump station 5.4 Water heat reservoir 5.5 Water storage tank 5.6 Heating station 6 Communication network 7 Construction, commissioning & debugging and acceptance 7.1 General requirements 7.2 Construction 7.3 Commissioning & debugging 7.4 Acceptance 8 Operation and maintenance 8.1 General requirements 8.2 Operation 8.3 Maintenance Annex A System debugging records Annex B System test records Explanation of wording in this specification List of quoted standards Explanation of provisions
Code of China
Standard
CJJ/T 241-2016  Technical specification for monitoring and controlling system of urban hfeating (English Version)
Standard No.CJJ/T 241-2016
Statusvalid
LanguageEnglish
File FormatPDF
Word Count38500 words
Price(USD)1150.0
Implemented on2017-5-1
Deliveryvia email in 1 business day
Detail of CJJ/T 241-2016
Standard No.
CJJ/T 241-2016
English Name
Technical specification for monitoring and controlling system of urban hfeating
Chinese Name
城镇供热监测与调控系统技术规程
Chinese Classification
Professional Classification
CJ
ICS Classification
Issued by
Ministry of Housing and Urban-Rural Construction of the People’s Republic of China
Issued on
2016-11-15
Implemented on
2017-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
38500 words
Price(USD)
1150.0
Keywords
CJJ/T 241-2016, CJJ 241-2016, CJJT 241-2016, CJJ/T241-2016, CJJ/T 241, CJJ/T241, CJJ241-2016, CJJ 241, CJJ241, CJJT241-2016, CJJT 241, CJJT241
Introduction of CJJ/T 241-2016
CJJ/T 241-2016 Technical specification for monitoring and controlling system of urban heating 1 General provisions 1.0.1 This specification is formulated in order to standardize the monitoring and control technology of urban heating system, ensure the safe, economic, energy-saving and environmental protection operation of urban heating system, and improve the operation and management level of urban heating system. 1.0.2 This specification is applicable to the design, construction, commissioning & debugging, acceptance, operation and maintenance of urban heating monitoring and controlling system. 1.0.3 The monitoring and control of urban heating system shall not only conform to this specification, but also conform to the current relevant national standards. 2 Terms 2.0.1 monitoring and controlling system software system and hardware facilities that collect, monitor, regulate, and control the main parameters and equipment operating state of various components of the heating system (including heating source outlets, pipe networks, heating stations, and other key parts) 2.0.2 monitoring center monitoring and controlling core hub that collects, processes, stores, transmits, retrieves, and displays information uploaded by local monitoring and controlling stations according to certain application purposes and rules, and issues monitoring instructions to each local monitoring and controlling station 2.0.3 local monitoring and controlling station system to realize local data acquisition, monitoring, control and communication 2.0.4 communication protocol rules and agreements that must be followed by both entities to complete communication or service 2.0.5 control strategy different control rules or countermeasures adopted to achieve control purposes 2.0.6 work station information processing system composed of computer, corresponding external equipment and application software 2.0.7 engineer station human-computer communication equipment between maintenance engineers and monitoring systems, which is used for debugging, modifying programs, and may also have the function of an operator station 2.0.8 operator station human-computer communication equipment between the on-duty personnel and the monitoring system, which is used for monitoring and control 3 Base requirements 3.0.1 The monitoring and controlling system of urban heating shall include monitoring center, communication network and local monitoring and controlling station. 3.0.2 The setting of monitoring and controlling system shall meet the requirements of operation and management. 3.0.3 The units and effective digits of monitoring data shall be unified. 3.0.4 The network security of the monitoring and controlling system shall comply with the following requirements: 1 The communication network of the monitoring center shall take security isolation measures, and the network exit shall be equipped with hardware firewall; 2 The communication network between monitoring center and key local monitoring and controlling station shall adopt redundant design and set up standby channel; 3 The communication network of the monitoring center shall identify and manage the system administrators and operators at different levels, and audit the operation of the system administrators.   3.0.5 The monitoring and controlling system of the newly-built heating project shall be designed, constructed and debugged simultaneously with the main heating project. 3.0.6 The password use and management of urban heating monitoring and controlling system shall comply with the national password administration regulations. 4 Monitoring center 4.1 General requirements 4.1.1 The monitoring center shall be set up according to factors such as heating scale and management need. 4.1.2 The setting of the computer room of the monitoring center shall comply with relevant requirements of the current national standard GB 50174 Code for design of electronic information system room. 4.2 Functions 4.2.1 The monitoring center shall have the following functions: 1 Operation monitoring; 2 Scheduling management; 3 Energy consumption management; 4 Fault diagnosis and alarm processing; 5 Data storage, statistics and analysis; 6 Centralized display. 4.2.2 The monitoring operation module shall have the following functions: 1 Display the process flow and operation parameters; 2 Monitor the operating state of the local monitoring and controlling station in real time; 3 Receive and record the alarm information of local monitoring and controlling station in real time, and form an alarm log; 4 Support multi-level authority management;
Contents of CJJ/T 241-2016
Foreword i 1 General provisions 2 Terms 3 Base requirements 4 Monitoring center 4.1 General requirements 4.2 Functions 4.3 Configuration 5 Local monitoring and controlling station 5.1 General requirements 5.2 Heating source plant 5.3 Booster pump station 5.4 Water heat reservoir 5.5 Water storage tank 5.6 Heating station 6 Communication network 7 Construction, commissioning & debugging and acceptance 7.1 General requirements 7.2 Construction 7.3 Commissioning & debugging 7.4 Acceptance 8 Operation and maintenance 8.1 General requirements 8.2 Operation 8.3 Maintenance Annex A System debugging records Annex B System test records Explanation of wording in this specification List of quoted standards Explanation of provisions
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
CJJ/T 241-2016, CJJ 241-2016, CJJT 241-2016, CJJ/T241-2016, CJJ/T 241, CJJ/T241, CJJ241-2016, CJJ 241, CJJ241, CJJT241-2016, CJJT 241, CJJT241