Testing method of dustiness for granular pesticide product
1 Scope
This standard specifies the testing method of dustiness for granular pesticide product.
This standard is applicable to the testing of dustiness in granular pesticide products.
2 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
2.1
granular pesticide
pesticide in dosage forms such as granules, water-dispersible granules, soluble granules, and effervescent granules
3 Test methods
3.1 Method summary
Weigh a certain amount of sample and freely drop them in the test space according to the specified conditions. The released dust is carried by the air flow, collected on the filter, and weighed to obtain the dust amount.
3.2 Apparatus
Dust meter (see Figure 1): consisting of a measuring box and a dumping tube (with the height of 600 mm). The top of the measuring box has a removable lid to which the dumping tube is attached. A filter is installed in the box, and is connected with the air flow meter and the vacuum pump;
Filter: with a pore size of 75 μm, and a diameter of 40 mm;
Air flow meter: 10 L/min to 20 L/min.
Balance: with a sensibility of 0.1 mg, precision of ± 0.1 mg;
Stopwatch;
Beaker: 100 mL;
Tweezers.
Foreword i
1 Scope
2 Terms and definitions
3 Test methods
Standard
GB/T 30360-2013 Testing Method of Dustiness for Granular Pesticide Product (English Version)
Standard No.
GB/T 30360-2013
Status
valid
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
60.0
Implemented on
2014-6-22
Delivery
via email in 1 business day
Detail of GB/T 30360-2013
Standard No.
GB/T 30360-2013
English Name
Testing Method of Dustiness for Granular Pesticide Product
Testing method of dustiness for granular pesticide product
1 Scope
This standard specifies the testing method of dustiness for granular pesticide product.
This standard is applicable to the testing of dustiness in granular pesticide products.
2 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
2.1
granular pesticide
pesticide in dosage forms such as granules, water-dispersible granules, soluble granules, and effervescent granules
3 Test methods
3.1 Method summary
Weigh a certain amount of sample and freely drop them in the test space according to the specified conditions. The released dust is carried by the air flow, collected on the filter, and weighed to obtain the dust amount.
3.2 Apparatus
Dust meter (see Figure 1): consisting of a measuring box and a dumping tube (with the height of 600 mm). The top of the measuring box has a removable lid to which the dumping tube is attached. A filter is installed in the box, and is connected with the air flow meter and the vacuum pump;
Filter: with a pore size of 75 μm, and a diameter of 40 mm;
Air flow meter: 10 L/min to 20 L/min.
Balance: with a sensibility of 0.1 mg, precision of ± 0.1 mg;
Stopwatch;
Beaker: 100 mL;
Tweezers.