2025-12-14 10.2.82.121
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/HG/T 20570.14-1995
HG/T 20570.14-1995   Setting of Personnel Protection Emergency System (English Version)
Standard No.: HG/T 20570.14-1995 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 2000 words Translation Price(USD):284.0 remind me the price change

Email:

Implemented on:1996-3-1 Delivery: via email in 1 business day

→ → →

,,1996-3-1,141137306102047ABA1D0C30F56BE
Standard No.: HG/T 20570.14-1995
English Name: Setting of Personnel Protection Emergency System
Chinese Name: 人身防护应急系统的设置
Chinese Classification: P7    
Professional Classification: HG    Professional Standard - Chemistry
Issued on: 1996-5-2
Implemented on: 1996-3-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 2000 words
Translation Price(USD): 284.0
Delivery: via email in 1 business day
1.0.1 The personnel protection emergency systems in the chemical plant and petrochemical plant include safe spray eyewash, protective mask, emergency oxygen respiratory system, special medicament, mechanical damage safeguard etc. This regulation only applies to the setting of the safe eyewash sprayer and eyewash equipment. 1.0.2 The personnel protection emergency measures shall be taken like setting the emergency spray eyewash (the so-called safe spray eyewash) if the chemical plant installations involves chemicals that burn or corrode human body, stimulate or penetrate human skin (including the mucosa and eyes), and tend to be absorbed by the human skin to harm the internal organ and tissue (the so-called toxic chemicals). 1.0.3 Setting place and position 1.0.3.1 The distance between the setting position of the safe spray eyewash and the potential accident point is related to the toxicity, corrosivity and temperature of the chemicals in use or production. The setting position and related requirements are generally put forward by production technology. (1) The safe spray eyewashes shall be set every 20 ~30 m near the handling, storing and analytical sampling points in the production and utilization area of the general toxic and mordant chemicals. (2) The safe spray eyewashes shall be set 3~6m (not be less than 3m) to the potential accident point (or dangerous zone) near the handling, storing and analytical sampling points in the production and utilization area of the virulent, highly corrosive chemicals or these whose temperature is over 70℃ as well as acidic or alkaline materials. 1.0.3.2 In the chemical analysis test room, the safe spray eyewashes shall be set in the post for the working people who will frequently use the toxic and corrosive reagents likely to harm human body. 1.0.3.3 The safe spray eyewashes shall be set near the charge room for the battery jar. 1.0.3.4 The safe spray eyewashes shall be set on the unobstructed passage, so they are often set in the same axial line or near the exit in the multi-storey factory buildings.
Code of China
Standard
HG/T 20570.14-1995  Setting of Personnel Protection Emergency System (English Version)
Standard No.HG/T 20570.14-1995
Statusvalid
LanguageEnglish
File FormatPDF
Word Count2000 words
Price(USD)284.0
Implemented on1996-3-1
Deliveryvia email in 1 business day
Detail of HG/T 20570.14-1995
Standard No.
HG/T 20570.14-1995
English Name
Setting of Personnel Protection Emergency System
Chinese Name
人身防护应急系统的设置
Chinese Classification
P7
Professional Classification
HG
ICS Classification
Issued by
Issued on
1996-5-2
Implemented on
1996-3-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
2000 words
Price(USD)
284.0
Keywords
HG/T 20570.14-1995, HG 20570.14-1995, HGT 20570.14-1995, HG/T20570.14-1995, HG/T 20570.14, HG/T20570.14, HG20570.14-1995, HG 20570.14, HG20570.14, HGT20570.14-1995, HGT 20570.14, HGT20570.14
Introduction of HG/T 20570.14-1995
1.0.1 The personnel protection emergency systems in the chemical plant and petrochemical plant include safe spray eyewash, protective mask, emergency oxygen respiratory system, special medicament, mechanical damage safeguard etc. This regulation only applies to the setting of the safe eyewash sprayer and eyewash equipment. 1.0.2 The personnel protection emergency measures shall be taken like setting the emergency spray eyewash (the so-called safe spray eyewash) if the chemical plant installations involves chemicals that burn or corrode human body, stimulate or penetrate human skin (including the mucosa and eyes), and tend to be absorbed by the human skin to harm the internal organ and tissue (the so-called toxic chemicals). 1.0.3 Setting place and position 1.0.3.1 The distance between the setting position of the safe spray eyewash and the potential accident point is related to the toxicity, corrosivity and temperature of the chemicals in use or production. The setting position and related requirements are generally put forward by production technology. (1) The safe spray eyewashes shall be set every 20 ~30 m near the handling, storing and analytical sampling points in the production and utilization area of the general toxic and mordant chemicals. (2) The safe spray eyewashes shall be set 3~6m (not be less than 3m) to the potential accident point (or dangerous zone) near the handling, storing and analytical sampling points in the production and utilization area of the virulent, highly corrosive chemicals or these whose temperature is over 70℃ as well as acidic or alkaline materials. 1.0.3.2 In the chemical analysis test room, the safe spray eyewashes shall be set in the post for the working people who will frequently use the toxic and corrosive reagents likely to harm human body. 1.0.3.3 The safe spray eyewashes shall be set near the charge room for the battery jar. 1.0.3.4 The safe spray eyewashes shall be set on the unobstructed passage, so they are often set in the same axial line or near the exit in the multi-storey factory buildings.
Contents of HG/T 20570.14-1995
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
HG/T 20570.14-1995, HG 20570.14-1995, HGT 20570.14-1995, HG/T20570.14-1995, HG/T 20570.14, HG/T20570.14, HG20570.14-1995, HG 20570.14, HG20570.14, HGT20570.14-1995, HGT 20570.14, HGT20570.14