2025-12-11 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/SL 269-2001
SL 269-2001   Design code for desiliting basin of water conservancy and hydropower projects (English Version)
Standard No.: SL 269-2001 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 11000 words Translation Price(USD):270.0 remind me the price change

Email:

Implemented on:2001-12-1 Delivery: via email in 1 business day

→ → →

,2019-12-30,2001-12-1,14113737980047B8D77E02BF4C8EA
Standard No.: SL 269-2001
English Name: Design code for desiliting basin of water conservancy and hydropower projects
Chinese Name: 水利水电工程沉沙池设计规范
Chinese Classification: P55    Water conservancy and water power engineering in general
Professional Classification: SL    Professional Standard - Water Resources
Source Content Issued by: MWR
Issued on: 2001-7-19
Implemented on: 2001-12-1
Status: superseded
Superseded by:SL/T 269-2019
Superseded on:2019-12-30
Target Language: English
File Format: PDF
Word Count: 11000 words
Translation Price(USD): 270.0
Delivery: via email in 1 business day
1 General Provisions 1.0.1 This code is developed with a view to unifying technical criteria on design of desilting basin in diversion structure of water conservancy and hydropower project, ensuring design quality and promoting the engineering development of the desilting basin. 1.0.2 This code is applicable to the design of Grade 3 desilting basin or above for treatment of suspended sediment in large and medium-sized water conservancy and hydropower projects. 1.0.3 In the design of the desilting basin, the basic data analysis shall be properly carried out. For important projects, combined method of theoretical analysis and model test is applied to determine the main arrangement dimension of the desilting basin. 1.0.4 For the arrangement and design of the desilting basin, technical and economical comparison must be carried out. 1.0.5 For the desilting basin, operation design shall be carried out and shall be consistent with the operation of the hydroproject. 1.0.6 In the design of the desilting basin, sediment prototype observation and safety monitoring designs shall be proposed. 1.0.7 The design of the desilting basin shall not only comply with this code, but also shall meet those specified in the relevant current national and professional standards. 2 Terms and Main Symbols 2.1 Terms 2.1.1 desilting basin the structure used to settle the suspended sediment whose sediment particle in sediment-laden flow is greater than the design settling diameter and reduce the sediment concentration in water flow it may be classified into hydraulic flushing desilting basin and non-flushing desilting basin according to operation modes. The former may be sub-classified into continuous flushing desilting basin and periodic flushing desilting basin 2.1.2 continuous flushing desilting basin the desilting basin that continuously flushes the settled sediment into the downstream watercourse during continuous water supply. The continuous flushing desilting basin consists of upstream connection section, working section, downstream connection section and flush gallery, as shown in Figures 2.1.2-1 and 2.1.2-2
Foreword i 1 General Provisions 2 Terms and Main Symbols 3 Design Data 4 Arrangement Conditions of Desilting Basin and Design Criteria of Sediment Settlement 5 Selection of Position and Type 6 Project Arrangement 7 Determination of Main Dimension 8 Structural Design 9 Operation Design 10 Prototype Observation and Safety Monitoring Design Annex A Settlement Calculation Method Annex B Settling Velocity Calculation of Suspended Sediment Annex C Flushing Calculation of Periodic Flushing Desilting Basin for Water Conservancy Project Annex D Hydraulic Calculation for Pressure and Non-pressure Sediment Flushing of Desilting Basin at Hydropower Station Explanation of Wording in this Code
Code of China
Standard
SL 269-2001  Design code for desiliting basin of water conservancy and hydropower projects (English Version)
Standard No.SL 269-2001
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count11000 words
Price(USD)270.0
Implemented on2001-12-1
Deliveryvia email in 1 business day
Detail of SL 269-2001
Standard No.
SL 269-2001
English Name
Design code for desiliting basin of water conservancy and hydropower projects
Chinese Name
水利水电工程沉沙池设计规范
Chinese Classification
P55
Professional Classification
SL
ICS Classification
Issued by
MWR
Issued on
2001-7-19
Implemented on
2001-12-1
Status
superseded
Superseded by
SL/T 269-2019
Superseded on
2019-12-30
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
11000 words
Price(USD)
270.0
Keywords
SL 269-2001, SL/T 269-2001, SLT 269-2001, SL269-2001, SL 269, SL269, SL/T269-2001, SL/T 269, SL/T269, SLT269-2001, SLT 269, SLT269
Introduction of SL 269-2001
1 General Provisions 1.0.1 This code is developed with a view to unifying technical criteria on design of desilting basin in diversion structure of water conservancy and hydropower project, ensuring design quality and promoting the engineering development of the desilting basin. 1.0.2 This code is applicable to the design of Grade 3 desilting basin or above for treatment of suspended sediment in large and medium-sized water conservancy and hydropower projects. 1.0.3 In the design of the desilting basin, the basic data analysis shall be properly carried out. For important projects, combined method of theoretical analysis and model test is applied to determine the main arrangement dimension of the desilting basin. 1.0.4 For the arrangement and design of the desilting basin, technical and economical comparison must be carried out. 1.0.5 For the desilting basin, operation design shall be carried out and shall be consistent with the operation of the hydroproject. 1.0.6 In the design of the desilting basin, sediment prototype observation and safety monitoring designs shall be proposed. 1.0.7 The design of the desilting basin shall not only comply with this code, but also shall meet those specified in the relevant current national and professional standards. 2 Terms and Main Symbols 2.1 Terms 2.1.1 desilting basin the structure used to settle the suspended sediment whose sediment particle in sediment-laden flow is greater than the design settling diameter and reduce the sediment concentration in water flow it may be classified into hydraulic flushing desilting basin and non-flushing desilting basin according to operation modes. The former may be sub-classified into continuous flushing desilting basin and periodic flushing desilting basin 2.1.2 continuous flushing desilting basin the desilting basin that continuously flushes the settled sediment into the downstream watercourse during continuous water supply. The continuous flushing desilting basin consists of upstream connection section, working section, downstream connection section and flush gallery, as shown in Figures 2.1.2-1 and 2.1.2-2
Contents of SL 269-2001
Foreword i 1 General Provisions 2 Terms and Main Symbols 3 Design Data 4 Arrangement Conditions of Desilting Basin and Design Criteria of Sediment Settlement 5 Selection of Position and Type 6 Project Arrangement 7 Determination of Main Dimension 8 Structural Design 9 Operation Design 10 Prototype Observation and Safety Monitoring Design Annex A Settlement Calculation Method Annex B Settling Velocity Calculation of Suspended Sediment Annex C Flushing Calculation of Periodic Flushing Desilting Basin for Water Conservancy Project Annex D Hydraulic Calculation for Pressure and Non-pressure Sediment Flushing of Desilting Basin at Hydropower Station Explanation of Wording in this Code
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
SL 269-2001, SL/T 269-2001, SLT 269-2001, SL269-2001, SL 269, SL269, SL/T269-2001, SL/T 269, SL/T269, SLT269-2001, SLT 269, SLT269