Contents
0 Introduction 1
1 Application Scope 1
2. Certification Standards 2
3 Certification Mode 2
4 Certification Unit Classification 3
5 Certification Entrustment 3
5.1 Proposal and Acceptance of Certification Entrustment 3
5.2 Application Information 3
5.3 Implementation Arrangement 4
6 Certification Implementation 4
6.1 Type Test 4
6.2 Certification Assessment and Determination 5
6.3 Certification Time Limit 5
7 Post-certification Supervision 6
7.1 Post-certification Follow-up Inspection 6
7.2 Sample Testing/Inspection on Production Site 6
7.3 Market Sample Testing/Inspection 7
7.4 Frequency and Timing of Post-certification Supervision 7
7.5 Record of Post-certification Supervision 7
7.6 Assessment of Post-certification Supervision Result 7
8 Certificate 8
8.1 Maintenance of Certificate 8
8.2 Change in Covered Products of Certificate 8
8.3 Expansion of Certificate Covered Product 9
8.4 Cancellation, Suspension and Revocation of Certificate 9
8.5 Use of Certificate 9
9 Certification Mark 9
9.1 Allowable Pattern of Mark 9
9.2 Marking Mode 10
10 Charge 10
11 Certification Responsibility 10
12 Certification Implementation Rules 10
0 Introduction
On the basis of safety risks and certification risks, the Rule is prepared to specify the basic principles and requirements on implementing compulsory certification for small power motors.
The Rule is used in association with CNCA general implementation rules like "Implementation Rule on Compulsory Certification - Selection and Determination of Classified Management and Certification Mode for Manufacturers", "Implementation Rule on Compulsory Certification - Utilization of Testing Resources and Other Certification Results of Manufacturers" and "Implementation Rule on Compulsory Certification - General Requirements of Factory Inspection".
The certification body shall, in accordance with the requirements of the general implementation rule and the Rule, prepare certification implementation rules, which shall be implemented in association with general implementation rule and the Rule.
The manufacturer shall ensure that its certified products continuously meet the requirements of certification and applicable standards.
1 Application Scope
The Rule is applicable to small power motors for driving with the rated voltage above 36V (excluding 36V), DC 1500V and AC below 1000V, including:
(1) (Where the rotational speed is converted to 1500r/min) all kinds of AC asynchronous motors and AC synchronous motors with the maximum continuous rated power not greater than 1.1kW;
(2) AC commutator motors and DC motors with the maximum continuous rated power not greater than 1.1kW.