2023-6-4 3.239.129.52
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/DB12/ 059-2018
DB12/ 059-2018   Emisson standards for odor pillutants (English Version)
Standard No.: DB12/ 059-2018 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 5000 words Price(USD):200.0 remind me the price change

Email:

Implemented on:2019-1-1 Delivery: via email in 1 business day
,,
Standard No.: DB12/ 059-2018
English Name: Emisson standards for odor pillutants
Chinese Name: 恶臭污染物排放标准
Professional Classification: DB    Provincial Standard
Issued on: 2018-12-27
Implemented on: 2019-1-1
Status: valid
Superseding:DB12/ 059-1995 Emission Standards for Odor Pollutants
Language: English
File Format: PDF
Word Count: 5000 words
Price(USD): 200.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is formulated in order to implement the Environmental protection law of the People's Republic of China, the Law of the People's Republic of China on the prevention and control of atmospheric pollution, the Regulations of Tianjin Municipality on Prevention and Control of Air Pollution and other laws and regulations, strengthen the emission control and management of odor pollutants in Tianjin, improve the ambient air quality, and protect human health. This standard is a revision of Emission Standard for Odor Pollutants (DB12/-059-95). The main contents of this revision are as follows: ——Eleven emission control requirements for odor pollutants have been added; ——The emission control requirements for some odor pollutants have become more stringent; ——The calculation method of the maximum allowable emission rate of the stack has been adjusted; ——The monitoring requirements has been updated. This standard is a general emission standard of air pollutant, and it is the basic requirement of odor pollutant emission control in Tianjin. The odor emission control requirements stipulated in the industrial pollutant emission standards issued by the state or Tianjin shall be implemented according to its provisions; unspecified odor emission control requirements shall be implemented in accordance with this standard. This standard was proposed by and is under the jurisdiction of the Tianjin Ecology and Environment Bureau. This standard was approved by Tianjin Municipal People’s Government on December 17th, 2018. This standard was first issued in November 1995, and is revised for the first time. Emission standards for odor pollutants 1 Application scope This standard specifies the requirements of emission limits, monitoring and control of odor pollutants from stationary pollution sources, as well as relevant provisions for the implementation and supervision of the standard. This standard is applicable to the odor pollutant emission management of the responsible subjects for odor pollution sources within the jurisdiction of Tianjin, as well as the environmental impact assessment of new construction, reconstruction and expansion projects, the design of environmental protection facilities, the completion and acceptance of environmental protection, the issuance of pollutant emission permission, and the management of odor pollutant emission after completion and operation. This standard is applicable to legal pollutant behaviors. The site selection of the existing pollution source and the management of the current pollution source in special protection areas shall comply with the relevant provisions specified in laws, regulations and rules such as Law of the People's Republic of China on the Prevention and Control of Atmospheric Pollution, Law of the People's Republic of China on Environmental Impact Assessment, Regulations of Tianjin Municipality on Environmental Protection and Regulations of Tianjin Municipality on Prevention and Control of Atmospheric Pollution. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For undated references, only the effective edition applies. GB/T 14675 Air quality - Determination of odor - Triangle odor bag method GB/T 14676 Air quality - Determination of trimethylamine - Gas chromatography GB/T 14678 Air quality - Determination of sulfuretted hydrogen, methyl sulfhydryl, dimethyl sulfide and dimethyl disulfide - Gas chromatography GB/T 14680 Air quality - Determination of carbon disulfide - Diethylamine spectrophometric method GB/T 16157 The determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source HJ 533 Air and exhaust gas - Determination of ammonia - Nessler’s reagent spectrophotometry HJ 534 Ambient air - Determination of ammonia - Sodium hypochlorite-salicylic acid spectrophotometry HJ 583 Ambient air - Determination of benzene and its analogies - Sorbent adsorption thermal desorption - Gas chromatography HJ 584 Ambient air - Determination of benzene and its analogies - Charcoal adsorption/carbon disulfide desorption - Gas chromatography HJ 644 Ambient Air - Determination of volatile organic compounds - Sorbent adsorption thermal desorption / gas chromatography - Mass spectrometry method HJ 683 Ambient air - Determination of aldehyde and ketone compounds - High performance liquid chromatography HJ 734 Stationary source emission - Determination of volatile organic compounds - Sorbent adsorption and thermal desorption gas chromatography mass spectrometry method HJ 759 Determination of volatile organic compounds - Ambient air - Determination of volatile organic compounds - Collected by specially-prepared canisters and analyzed by gas chromatography/mass spectrometry HJ 905 Technical specification for environmental monitoring of odor pollution HJ 819 Technical guidelines for self-monitoring of sewage disposal units - General provisions Measures for the Administration of Environmental Monitoring (Decree No.39 of the Ministry of Ecology and Environment of the People's Republic of China) 3 Terms and definitions For the purposes of this standard, the following terms and definitions apply. 3.1 odor all odor gases that stimulate the olfactory organs, cause people to feel unpleasant and damage the living environment 3.2 responsibility subject of odor pollution source enterprises, institutions and other producers and operators that produce odor pollutants in production and business activities 3.3 odor concentration dilution ratio of the odor sample continuously diluted with odorless air to the olfactory threshold 3.4 maximum allowable emission rate upper limit of pollutants mass emitted in any one hour by a stack at a certain height   3.5 stack height the height measured from the ground plane where the stack (or its main building structure) is located to the outlet of the stack, m 3.6 boundary legal boundary of responsible subject of odor pollution source. or actual boundary If the legal boundary cannot be determined 3.7 existing pollution source enterprises or facilities that have been established and put into production and whose environmental impact assessment documents have been approved before the date of implementation of this standard. 3.8 new pollution source New construction, reconstruction and expansion projects whose environmental impact assessment documents are approved from the implementation date of this standard. 4 Requirements for pollutants emission control 4.1 Existing pollution sources shall be implemented from the implementation date of this standard: existing pollution sources shall be implemented from January 1, 2020. 4.2 limits for pollutants emission and boundary concentration The responsible subjects of odor pollution sources shall be compared with the control items in Table 1 and Table 2, actively identify the odor pollutants emitted by them, and take effective control measures to make them meet the corresponding limits in Table 1 and Table 2.
Foreword i 1 Application scope 2 Normative references 3 Terms and definitions 4 Requirements for pollutants emission control 5 Requirements for pollutant monitoring 6 Implementation and supervision Annex A (Normative) Calculation of maximum allowable emission rate of stack by interpolation method Annex B (Normative) Calculation method of parameters relevant to equivalent stacks
Referred in DB12/ 059-2018:
*GB/T 14675-1993 Air quality-Determination of odor-Triangle odor bag method
*GB/T 14676-1993 Air quality -Determination of trimethylamine -Gas chromatography
*GB/T 14678-1993 Air quality -Determination of sulfuretted hydrogen, methyl sulfhydryl, dimethyl sulfide and dimethyl disulfide -Gas chromatography
*GB/T 14680-1993 Air quality-Determination of carben disulfide-Diethylamine spectrophometric method
*GB/T 16157-1996/XG1-2017 The determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source, including Amendment 1
*HJ 533-2009 Air and exhaust gas―Determination of ammonia―Nessler’s reagent spetcrophotometry
*HJ 534-2009 Ambient air―Determination of ammonia― Sodium hypochlorite - salicylic acid spectrophotometry
*HJ 583-2010 Ambient air—Determination of benzene and its analogies using sorbent adsorption thermal desorption and Gas Chromatography
*HJ 584-2010 Ambient air—Determination of benzene and its analogies by activated charcoal adsorption carbon disulfide desorption and gas chromatography
*HJ 644-2013 Ambient air - Determination of volatile organic compounds-Sorbent adsorption and thermal desorption/gas chromatography mass spectrometry method
*HJ 683-2014 Ambient air-Determination of aldehyde and ketone compounds-High performance liquid chromatography
*HJ 734-2014 Stationary source emission -Determination of volatile organic compounds-Sorbent adsorption and thermal desorption gas chromatography mass spectrometry method (For Release)
*HJ 759-2015 Ambient air-Determination of volatile organic compounds- Collected by specially-prepared canistersand analyzed by gas chromatography/mass spectrometry
*HJ 905-2017 Technical specification for environmental monitoring of odor
*HJ 819-2017 Self-monitoring technology guidelines for pollution sources―General rule
Code of China
Standard
DB12/ 059-2018  Emisson standards for odor pillutants (English Version)
Standard No.DB12/ 059-2018
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5000 words
Price(USD)200.0
Implemented on2019-1-1
Deliveryvia email in 1 business day
Detail of DB12/ 059-2018
Standard No.
DB12/ 059-2018
English Name
Emisson standards for odor pillutants
Chinese Name
恶臭污染物排放标准
Chinese Classification
Professional Classification
DB
ICS Classification
Issued by
Issued on
2018-12-27
Implemented on
2019-1-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
DB12/ 059-1995 Emission Standards for Odor Pollutants
Language
English
File Format
PDF
Word Count
5000 words
Price(USD)
200.0
Keywords
DB12/ 059-2018, DB12/T 059-2018, DB12T 059-2018, DB12/059-2018, DB12/ 059, DB12/059, DB12/T059-2018, DB12/T 059, DB12/T059, DB12T059-2018, DB12T 059, DB12T059
Introduction of DB12/ 059-2018
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is formulated in order to implement the Environmental protection law of the People's Republic of China, the Law of the People's Republic of China on the prevention and control of atmospheric pollution, the Regulations of Tianjin Municipality on Prevention and Control of Air Pollution and other laws and regulations, strengthen the emission control and management of odor pollutants in Tianjin, improve the ambient air quality, and protect human health. This standard is a revision of Emission Standard for Odor Pollutants (DB12/-059-95). The main contents of this revision are as follows: ——Eleven emission control requirements for odor pollutants have been added; ——The emission control requirements for some odor pollutants have become more stringent; ——The calculation method of the maximum allowable emission rate of the stack has been adjusted; ——The monitoring requirements has been updated. This standard is a general emission standard of air pollutant, and it is the basic requirement of odor pollutant emission control in Tianjin. The odor emission control requirements stipulated in the industrial pollutant emission standards issued by the state or Tianjin shall be implemented according to its provisions; unspecified odor emission control requirements shall be implemented in accordance with this standard. This standard was proposed by and is under the jurisdiction of the Tianjin Ecology and Environment Bureau. This standard was approved by Tianjin Municipal People’s Government on December 17th, 2018. This standard was first issued in November 1995, and is revised for the first time. Emission standards for odor pollutants 1 Application scope This standard specifies the requirements of emission limits, monitoring and control of odor pollutants from stationary pollution sources, as well as relevant provisions for the implementation and supervision of the standard. This standard is applicable to the odor pollutant emission management of the responsible subjects for odor pollution sources within the jurisdiction of Tianjin, as well as the environmental impact assessment of new construction, reconstruction and expansion projects, the design of environmental protection facilities, the completion and acceptance of environmental protection, the issuance of pollutant emission permission, and the management of odor pollutant emission after completion and operation. This standard is applicable to legal pollutant behaviors. The site selection of the existing pollution source and the management of the current pollution source in special protection areas shall comply with the relevant provisions specified in laws, regulations and rules such as Law of the People's Republic of China on the Prevention and Control of Atmospheric Pollution, Law of the People's Republic of China on Environmental Impact Assessment, Regulations of Tianjin Municipality on Environmental Protection and Regulations of Tianjin Municipality on Prevention and Control of Atmospheric Pollution. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For undated references, only the effective edition applies. GB/T 14675 Air quality - Determination of odor - Triangle odor bag method GB/T 14676 Air quality - Determination of trimethylamine - Gas chromatography GB/T 14678 Air quality - Determination of sulfuretted hydrogen, methyl sulfhydryl, dimethyl sulfide and dimethyl disulfide - Gas chromatography GB/T 14680 Air quality - Determination of carbon disulfide - Diethylamine spectrophometric method GB/T 16157 The determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source HJ 533 Air and exhaust gas - Determination of ammonia - Nessler’s reagent spectrophotometry HJ 534 Ambient air - Determination of ammonia - Sodium hypochlorite-salicylic acid spectrophotometry HJ 583 Ambient air - Determination of benzene and its analogies - Sorbent adsorption thermal desorption - Gas chromatography HJ 584 Ambient air - Determination of benzene and its analogies - Charcoal adsorption/carbon disulfide desorption - Gas chromatography HJ 644 Ambient Air - Determination of volatile organic compounds - Sorbent adsorption thermal desorption / gas chromatography - Mass spectrometry method HJ 683 Ambient air - Determination of aldehyde and ketone compounds - High performance liquid chromatography HJ 734 Stationary source emission - Determination of volatile organic compounds - Sorbent adsorption and thermal desorption gas chromatography mass spectrometry method HJ 759 Determination of volatile organic compounds - Ambient air - Determination of volatile organic compounds - Collected by specially-prepared canisters and analyzed by gas chromatography/mass spectrometry HJ 905 Technical specification for environmental monitoring of odor pollution HJ 819 Technical guidelines for self-monitoring of sewage disposal units - General provisions Measures for the Administration of Environmental Monitoring (Decree No.39 of the Ministry of Ecology and Environment of the People's Republic of China) 3 Terms and definitions For the purposes of this standard, the following terms and definitions apply. 3.1 odor all odor gases that stimulate the olfactory organs, cause people to feel unpleasant and damage the living environment 3.2 responsibility subject of odor pollution source enterprises, institutions and other producers and operators that produce odor pollutants in production and business activities 3.3 odor concentration dilution ratio of the odor sample continuously diluted with odorless air to the olfactory threshold 3.4 maximum allowable emission rate upper limit of pollutants mass emitted in any one hour by a stack at a certain height   3.5 stack height the height measured from the ground plane where the stack (or its main building structure) is located to the outlet of the stack, m 3.6 boundary legal boundary of responsible subject of odor pollution source. or actual boundary If the legal boundary cannot be determined 3.7 existing pollution source enterprises or facilities that have been established and put into production and whose environmental impact assessment documents have been approved before the date of implementation of this standard. 3.8 new pollution source New construction, reconstruction and expansion projects whose environmental impact assessment documents are approved from the implementation date of this standard. 4 Requirements for pollutants emission control 4.1 Existing pollution sources shall be implemented from the implementation date of this standard: existing pollution sources shall be implemented from January 1, 2020. 4.2 limits for pollutants emission and boundary concentration The responsible subjects of odor pollution sources shall be compared with the control items in Table 1 and Table 2, actively identify the odor pollutants emitted by them, and take effective control measures to make them meet the corresponding limits in Table 1 and Table 2.
Contents of DB12/ 059-2018
Foreword i 1 Application scope 2 Normative references 3 Terms and definitions 4 Requirements for pollutants emission control 5 Requirements for pollutant monitoring 6 Implementation and supervision Annex A (Normative) Calculation of maximum allowable emission rate of stack by interpolation method Annex B (Normative) Calculation method of parameters relevant to equivalent stacks
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
DB12/ 059-2018, DB12/T 059-2018, DB12T 059-2018, DB12/059-2018, DB12/ 059, DB12/059, DB12/T059-2018, DB12/T 059, DB12/T059, DB12T059-2018, DB12T 059, DB12T059