Chapter 1 General Provisions …………………………………………………………
Chapter 2 Terms and Symbols ……………………………………………………..
2.1 Terms …………………………………………………………………………...
2.2 Main Symbols …………………………………………………………………..
Chapter 3 Materials ……………………………………………………………………
3.1 General Requirements …………………………………………………………..
3.2 Mechanical Properties …………………………………………………………..
3.3 Aluminium ……………………………………………………………………...
3.4 Steel ……………………………………………………………………………..
3.5 Glass …………………………………………………………………………….
3.6 Metal Panels …………………………………………………………………….
3.7 Stone Panels …………………………………………………………………….
3.8 Artificial Panels ………………………………………………………………...
3.9 Composite Panels ……………………………………………………………….
3.10 Connection and Fixings ……………………………………………………….
3.11 Structural and Weather Sealant ……………………………………………......
3.12 Fireproofing Materials ………………………………………………………...
3.13 Thermal Insulation Materials ………………………………………………….
3.14 Others ………………………………………………………………………….
Chapter 4 Architectural Design ………………………………………………………..
4.1 General Requirements …………………………………………………………..
4.2 Performance-Based Design ……………………………………………………..
4.3 Safety Measures ………………………………………………………………...
4.4 Detailing ………………………………………………………………………...
4.5 Curtain Wall Design in Architectural Document ……………………………….
4.6 Principles of Curtain Wall Design Document …………………………………..
Chapter 5 Daylight Reflection of Curtain Wall ……………………………………….
5.1 General Requirements …………………………………………………………..
5.2 Architectural Design ……………………………………………………………
5.3 Reduction Measures of Daylight Reflection ……………………………………
5.4 Environmental Analysis ………………………………………………………...
Chapter 6 Thermal Performance Design …………………………………………. …..
6.1 General Requirements …………………………………………………………..
6.2 Detailing ………………………………………………………………………...
Chapter 7 Fireproofing ……………………………………………………………..
7.1 General Requirements …………………………………………………………..
7.2 Detailing ………………………………………………………………………...
7.3 Fireproofing Design for Double Skin Facade ………………………………...
Chapter 8 Lightning Protection ………………………………………………………..
8.1 General Requirements …………………………………………………………..
8.2 Detailing ………………………………………………………………………...
8.3 Others …………………………………………………………………………...
Chapter 9 Water Penetration and Leaking Prevention ………………………………...
9.1 General Requirements …………………………………………………………..
9.2 Exterior Walls Detailing Requirements ………………………………………...
9.3 Operable Windows of Curtain Wall …………………………………………….
9.4 Skylight and Metal Roofing …………………………………………………….
Chapter 10 Basic Requirements for Structural Design ………………………………..
10.1 General Requirements …………………………………………………………
10.2 Loads and Earthquake Actions ………………………………………………..
10.3 Calculations of Loads and Earthquake Actions ……………………………….
10.4 Load Combinations ……………………………………………………………
10.5 Curtain Wall Connection Design ………………………………………………
10.6 Design for Structural Silicon Sealant and Glazing Panel Installation …………
10.7 Design of Fasteners Connection ……………………………………………….
Chapter 11 Panel Design ………………………………………………………………
11.1 General Requirements …………………………………………………………
11.2 Glass Panels …………………………………………………………………...
11.3 Metal Panels …………………………………………………………………..
11.4 Stone Panels …………………………………………………………………...
11.5 Artificial Panels ………………………………………………………………..
11.6 Composite Panels ……………………………………………………………...
Chapter 12 Windows and Doors ………………………………………………………
12.1 General Requirements …………………………………………………………
12.2 Detailing ………………………………………………………………………
12.3 Detailing of Operable Windows on Skylight System …………………………
Chapter 13 Stick Curtain Wall …………………………………………………….. …
13.1 General Requirements …………………………………………………………
13.2 Detailing: Transom …………………………………………………………….
13.3 Detailing: Mullion ……………………………………………………………..
13.4 Structure Design of Transom ………………………………………………….
13.5 Structure Design of Mullion …………………………………………………...
Chapter 14 Unitized Curtain Wall ………………………………………………...
14.1 General Requirements …………………………………………………………
14.2 Detailing ……………………………………………………………………….
14.3 Structure Design ……………………………………………………………….
14.4 Connection Design …………………………………………………………….
Chapter 15 Double-Skin Facade ………………………………………………………
15.1 General Requirements …………………………………………………………
15.2 Detailing ……………………………………………………………………….
15.3 Ventilation Volume Calculation ………………………………………………
15.4 Thermal Design ………………………………………………………………..
15.5 Water Proofing ………………………………………………………………...
Chapter 16 Full Glass Curtain Wall …………………………………………………
16.1 General Requirements …………………………………………………………
16.2 Detailing ……………………………………………………………………….
16.3 Structure Design ……………………………………………………………….
Chapter 17 Point Supported Glass Curtain Wall ………………………………………
17.1 General Requirements …………………………………………………………
17.2 Design of Steel Member/Truss Supported Structures …………………………
17.3 Design of Cable Structure ……………………………………………………..
17.4 Design of Tension Rods or Cable-Rod Truss Supported Structures …………..
17.5 Design of One-way or Two-way Cable Net Supported Structure ……………..
17.6 Joint Design and Glass Fittings ………………………………………………..
Chapter 18 Skylight, Canopy and Metal Roofing ……………………………………..
18.1 General Requirements …………………………………………………………
18.2 Structure Design ……………………………………………………………….
18.3 Drainage Design ……………………………………………………………….
18.4 Detailing ……………………………………………………………………….
18.5 Cable-Structure Supported Skylight …………………………………………..
Chapter 19 Steel Structure for Curtain Wall …………………………………………..
19.1 General Requirements …………………………………………………………
19.2 Structure Design and Detailing ………………………………………………..
19.3 Connection Design …………………………………………………………….
19.4 Corrosion Protection …………………………………………………………..
Chapter 20 Photovoltaic Curtain Wall …………………………………………….. …
20.1 General Requirements …………………………………………………………
20.2 System Design …………………………………………………………………
Chapter 21 Curtain Wall Information Model ………………………………………….
21.1 General Requirements …………………………………………………………
21.2 Modeling ………………………………………………………………………
21.3 Model Application …………………………………………………………….
21.4 Deliverables ……………………………………………………………………
21.5 Levels of Detail ………………………………………………………………..
Chapter 22 Inspection and Testing …………………………………………………….
22.1 General Requirements …………………………………………………………
22.2 Material Inspection …………………………………………………………….
22.3 Site Inspection …………………………………………………………………
22.4 Performance Testing …………………………………………………………..
Chapter 23 Manufacture and Fabrication ………………………………………….. …
23.1 General Requirements …………………………………………………………
23.2 Fabrication of Metal Components ……………………………………………..
23.3 Processing of Glass Panels …………………………………………………….
23.4 Fabrication of Metal Panels …………………………………………………...
23.5 Fabrication of Stone and Other Panels…………………………………………
23.6 Assembling ……………………………………………………………………
23.7 Components Inspection ………………………………………………………
Chapter 24 Erection and Construction…………………………………………………
24.1 General Requirements …………………………………………………………
24.2 Stick Curtain Wall ……………………………………………………………..
24.3 Unitized Curtain Wall …………………………………………………………
24.4 Full Glass Curtain Wall ………………………………………………………..
24.5 Point Supported Glass Curtain Wall …………………………………………..
24.6 Curtain Wall with PV System …………………………………………………
24.7 Safety Requirements …………………………………………………………..
Chapter 25 Acceptance Inspection …………………………………………………….
25.1 General Requirements …………………………………………………………
25.2 Site Entering Inspection ……………………………………………………….
25.3 Mid-Term Inspection ………………………………………………………….
25.4 Acceptance Inspection ………………………………………………………...
Chapter 26 Maintenance ………………………………………………………………
26.1 General Requirements …………………………………………………………
26.2 Investigation and Repairing …………………………………………………...
26.3 Maintenance and Cleaning …………………………………………………….
Appendix A Exposure Category for Design Wind Load of Curtain Wall …………….
Appendix B Method for Environmental Evaluation of Curtain Wall Daylight Reflection …………………………………………………………………
Appendix C Insulating Profile with Thermal Barrier …………………………………
Appendix D Design and Details of Embedment and Post-installed Fastenings ………
Appendix E Moment-Coefficients of Metal and Stone Panels ……………………. …
Appendix F Moment and Shear Coefficients of Two-way Ribbed Panels ……………
Appendix G Coefficients of Continuous Beam with Hinges ………………………….
Appendix H Strength Reduction Coefficients of Aluminium Mullions with Open Sections ………………………………………………………………….
Appendix J Sound Insulation Calculation for Double-Skin Facade …………………..
Explanation of Wording in This Standard ………………………………………………
List of Quoted Standards ………………………………………………………………..
 |
|
Standard
| DG/TJ 08-56-2019 TECHNICAL STANDARD FOR BUILDING CURTAIN WALL (Shanghai) (English Version) |
Detail of DG/TJ 08-56-2019
| Standard No. |
| English Name |
| Chinese Name |
| Chinese Classification |
| Professional Classification |
| ICS Classification |
| Issued by |
| Issued on |
| Implemented on |
| Status |
| Superseded by |
| Superseded on |
| Abolished on |
| Superseding |
| Language |
| File Format |
| Word Count |
| Price(USD) |
| Keywords |
Introduction of DG/TJ 08-56-2019
DG/TJ 08-56-2019 TECHNICAL STANDARD FOR BUILDING CURTAIN WALL (Shanghai)
Contents of DG/TJ 08-56-2019
CONTENTS
Chapter 1 General Provisions …………………………………………………………
Chapter 2 Terms and Symbols ……………………………………………………..
2.1 Terms …………………………………………………………………………...
2.2 Main Symbols …………………………………………………………………..
Chapter 3 Materials ……………………………………………………………………
3.1 General Requirements …………………………………………………………..
3.2 Mechanical Properties …………………………………………………………..
3.3 Aluminium ……………………………………………………………………...
3.4 Steel ……………………………………………………………………………..
3.5 Glass …………………………………………………………………………….
3.6 Metal Panels …………………………………………………………………….
3.7 Stone Panels …………………………………………………………………….
3.8 Artificial Panels ………………………………………………………………...
3.9 Composite Panels ……………………………………………………………….
3.10 Connection and Fixings ……………………………………………………….
3.11 Structural and Weather Sealant ……………………………………………......
3.12 Fireproofing Materials ………………………………………………………...
3.13 Thermal Insulation Materials ………………………………………………….
3.14 Others ………………………………………………………………………….
Chapter 4 Architectural Design ………………………………………………………..
4.1 General Requirements …………………………………………………………..
4.2 Performance-Based Design ……………………………………………………..
4.3 Safety Measures ………………………………………………………………...
4.4 Detailing ………………………………………………………………………...
4.5 Curtain Wall Design in Architectural Document ……………………………….
4.6 Principles of Curtain Wall Design Document …………………………………..
Chapter 5 Daylight Reflection of Curtain Wall ……………………………………….
5.1 General Requirements …………………………………………………………..
5.2 Architectural Design ……………………………………………………………
5.3 Reduction Measures of Daylight Reflection ……………………………………
5.4 Environmental Analysis ………………………………………………………...
Chapter 6 Thermal Performance Design …………………………………………. …..
6.1 General Requirements …………………………………………………………..
6.2 Detailing ………………………………………………………………………...
Chapter 7 Fireproofing ……………………………………………………………..
7.1 General Requirements …………………………………………………………..
7.2 Detailing ………………………………………………………………………...
7.3 Fireproofing Design for Double Skin Facade ………………………………...
Chapter 8 Lightning Protection ………………………………………………………..
8.1 General Requirements …………………………………………………………..
8.2 Detailing ………………………………………………………………………...
8.3 Others …………………………………………………………………………...
Chapter 9 Water Penetration and Leaking Prevention ………………………………...
9.1 General Requirements …………………………………………………………..
9.2 Exterior Walls Detailing Requirements ………………………………………...
9.3 Operable Windows of Curtain Wall …………………………………………….
9.4 Skylight and Metal Roofing …………………………………………………….
Chapter 10 Basic Requirements for Structural Design ………………………………..
10.1 General Requirements …………………………………………………………
10.2 Loads and Earthquake Actions ………………………………………………..
10.3 Calculations of Loads and Earthquake Actions ……………………………….
10.4 Load Combinations ……………………………………………………………
10.5 Curtain Wall Connection Design ………………………………………………
10.6 Design for Structural Silicon Sealant and Glazing Panel Installation …………
10.7 Design of Fasteners Connection ……………………………………………….
Chapter 11 Panel Design ………………………………………………………………
11.1 General Requirements …………………………………………………………
11.2 Glass Panels …………………………………………………………………...
11.3 Metal Panels …………………………………………………………………..
11.4 Stone Panels …………………………………………………………………...
11.5 Artificial Panels ………………………………………………………………..
11.6 Composite Panels ……………………………………………………………...
Chapter 12 Windows and Doors ………………………………………………………
12.1 General Requirements …………………………………………………………
12.2 Detailing ………………………………………………………………………
12.3 Detailing of Operable Windows on Skylight System …………………………
Chapter 13 Stick Curtain Wall …………………………………………………….. …
13.1 General Requirements …………………………………………………………
13.2 Detailing: Transom …………………………………………………………….
13.3 Detailing: Mullion ……………………………………………………………..
13.4 Structure Design of Transom ………………………………………………….
13.5 Structure Design of Mullion …………………………………………………...
Chapter 14 Unitized Curtain Wall ………………………………………………...
14.1 General Requirements …………………………………………………………
14.2 Detailing ……………………………………………………………………….
14.3 Structure Design ……………………………………………………………….
14.4 Connection Design …………………………………………………………….
Chapter 15 Double-Skin Facade ………………………………………………………
15.1 General Requirements …………………………………………………………
15.2 Detailing ……………………………………………………………………….
15.3 Ventilation Volume Calculation ………………………………………………
15.4 Thermal Design ………………………………………………………………..
15.5 Water Proofing ………………………………………………………………...
Chapter 16 Full Glass Curtain Wall …………………………………………………
16.1 General Requirements …………………………………………………………
16.2 Detailing ……………………………………………………………………….
16.3 Structure Design ……………………………………………………………….
Chapter 17 Point Supported Glass Curtain Wall ………………………………………
17.1 General Requirements …………………………………………………………
17.2 Design of Steel Member/Truss Supported Structures …………………………
17.3 Design of Cable Structure ……………………………………………………..
17.4 Design of Tension Rods or Cable-Rod Truss Supported Structures …………..
17.5 Design of One-way or Two-way Cable Net Supported Structure ……………..
17.6 Joint Design and Glass Fittings ………………………………………………..
Chapter 18 Skylight, Canopy and Metal Roofing ……………………………………..
18.1 General Requirements …………………………………………………………
18.2 Structure Design ……………………………………………………………….
18.3 Drainage Design ……………………………………………………………….
18.4 Detailing ……………………………………………………………………….
18.5 Cable-Structure Supported Skylight …………………………………………..
Chapter 19 Steel Structure for Curtain Wall …………………………………………..
19.1 General Requirements …………………………………………………………
19.2 Structure Design and Detailing ………………………………………………..
19.3 Connection Design …………………………………………………………….
19.4 Corrosion Protection …………………………………………………………..
Chapter 20 Photovoltaic Curtain Wall …………………………………………….. …
20.1 General Requirements …………………………………………………………
20.2 System Design …………………………………………………………………
Chapter 21 Curtain Wall Information Model ………………………………………….
21.1 General Requirements …………………………………………………………
21.2 Modeling ………………………………………………………………………
21.3 Model Application …………………………………………………………….
21.4 Deliverables ……………………………………………………………………
21.5 Levels of Detail ………………………………………………………………..
Chapter 22 Inspection and Testing …………………………………………………….
22.1 General Requirements …………………………………………………………
22.2 Material Inspection …………………………………………………………….
22.3 Site Inspection …………………………………………………………………
22.4 Performance Testing …………………………………………………………..
Chapter 23 Manufacture and Fabrication ………………………………………….. …
23.1 General Requirements …………………………………………………………
23.2 Fabrication of Metal Components ……………………………………………..
23.3 Processing of Glass Panels …………………………………………………….
23.4 Fabrication of Metal Panels …………………………………………………...
23.5 Fabrication of Stone and Other Panels…………………………………………
23.6 Assembling ……………………………………………………………………
23.7 Components Inspection ………………………………………………………
Chapter 24 Erection and Construction…………………………………………………
24.1 General Requirements …………………………………………………………
24.2 Stick Curtain Wall ……………………………………………………………..
24.3 Unitized Curtain Wall …………………………………………………………
24.4 Full Glass Curtain Wall ………………………………………………………..
24.5 Point Supported Glass Curtain Wall …………………………………………..
24.6 Curtain Wall with PV System …………………………………………………
24.7 Safety Requirements …………………………………………………………..
Chapter 25 Acceptance Inspection …………………………………………………….
25.1 General Requirements …………………………………………………………
25.2 Site Entering Inspection ……………………………………………………….
25.3 Mid-Term Inspection ………………………………………………………….
25.4 Acceptance Inspection ………………………………………………………...
Chapter 26 Maintenance ………………………………………………………………
26.1 General Requirements …………………………………………………………
26.2 Investigation and Repairing …………………………………………………...
26.3 Maintenance and Cleaning …………………………………………………….
Appendix A Exposure Category for Design Wind Load of Curtain Wall …………….
Appendix B Method for Environmental Evaluation of Curtain Wall Daylight Reflection …………………………………………………………………
Appendix C Insulating Profile with Thermal Barrier …………………………………
Appendix D Design and Details of Embedment and Post-installed Fastenings ………
Appendix E Moment-Coefficients of Metal and Stone Panels ……………………. …
Appendix F Moment and Shear Coefficients of Two-way Ribbed Panels ……………
Appendix G Coefficients of Continuous Beam with Hinges ………………………….
Appendix H Strength Reduction Coefficients of Aluminium Mullions with Open Sections ………………………………………………………………….
Appendix J Sound Insulation Calculation for Double-Skin Facade …………………..