2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/DL/T 1190-2012
DL/T 1190-2012   The Insulation Piercing Connector for Rated Voltages up to 10kV (English Version)
Standard No.: DL/T 1190-2012 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5000 words Translation Price(USD):120.0 remind me the price change

Email:

Implemented on:2012-12-1 Delivery: via email in 1 business day

→ → →

,2024-4-11,2012-12-1,1411377855543020BE95D8AA0AB68
Standard No.: DL/T 1190-2012
English Name: The Insulation Piercing Connector for Rated Voltages up to 10kV
Chinese Name: 额定电压10kV及以下绝缘穿刺线夹
Chinese Classification: K10    Electrotechnical material and universal parts in general
Professional Classification: DL    Professional Standard - Electricity
Source Content Issued by: National Energy Administration
Issued on: 2012-8-23
Implemented on: 2012-12-1
Status: superseded
Superseded by:DL/T 1190-2023 Insulation piercing connectors
Superseded on:2024-4-11
Target Language: English
File Format: PDF
Word Count: 5000 words
Translation Price(USD): 120.0
Delivery: via email in 1 business day
1 Scope This standard specifies the technical requirements, tests, inspection rules, marking and packaging of the insulation piercing connector for rated voltages up to 10kV. This standard is applicable to the insulation piercing connectors used for aerial insulated wire, bridge and culvert, adit, tunnel, mineral drive and wire pipe shaft with rated voltage for rated voltage up to 10KV. 2 Normative References The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments to (excluding amending errors in the text), or revisions of, any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to study whether the latest edition of the normative document is applicable. For undated references, the latest edition of the normative document applies. GB/T 2314 General Technical Requirements for Electric Power Fittings GB/T 2317.3 Test Method for Electric Power Fittings - Part 3: Heat Cycle Tests for Electric Power Fittings GB/T 3048.7 Test Methods for Electrical Properties of Electric Cables and Wires - Part 7: Tracking Resistance Test GB/T 12527 Aerial Insulated Cables of Rated Voltage Up to and including 1kV GB/T 14049 Aerial Insulated Cables for Rated Voltage of 10kV GB/T 16927.1 High Voltage Test Techniques - Part 1: General Test Requirements GB/T 16927.2 High Voltage Test Techniques - Part 2: Measuring Systems DL/T 765.1 Technical Requirements for Distribution Fittings DL/T 765.3 Overhead Insulated Conductor Fittings of Rated Voltages Up to 10kv DL/T 768.7 Manufacture Quality Specification for Electric Power Fittings Hot Dip Galvanized Coatings on Fabricated Iron and Steel Articles 3 Terms and Definitions
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Technical Requirements 5 Tests 6 Inspection Rules 7 Marking and Packaging Appendix A (Informative) Installation Requirements Appendix B (Normative) Resistance Test Arrangement and Calculation Appendix C (Normative) Typical Test Loop of Electrical Test Appendix D (Informative) Bibliography
Referred in DL/T 1190-2012:
* GB/T 2314-2008 General Technical Requirements for Electric Power Fittings
* GB/T 2317.3-2008 Test method for electric power fittings - Part 3: Heat cycle tests for electric power fittings
* GB/T 3048.7-2007 Test methods for electrical properties of electric cables and wires—Part 7:Tracking resistance test
* GB/T 12527-2008 Aerial insulated cables for rated voltages up to and including 1kV
* GB/T 14049-2008 Aerial insulated cables for rated voltage of 10kV
* GB/T 16927.1-2011 High-voltage test techniques—Part 1:General definitions and test requirements
* GB/T 16927.2-2013 High-voltage test techniques—Part 2:Measuring systems
* DL/T 765.1-2001 Technical requirements for distribution fittings
* DL/T 765.3-2004 Overhead insulated conductor fittings of rated voltages up to 10kv
* DL/T 768.7-2012 Manufacture quality specification for electric power fittings hot dip galvanized coatings on fabricated iron and steel articles
Code of China
Standard
DL/T 1190-2012  The Insulation Piercing Connector for Rated Voltages up to 10kV (English Version)
Standard No.DL/T 1190-2012
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count5000 words
Price(USD)120.0
Implemented on2012-12-1
Deliveryvia email in 1 business day
Detail of DL/T 1190-2012
Standard No.
DL/T 1190-2012
English Name
The Insulation Piercing Connector for Rated Voltages up to 10kV
Chinese Name
额定电压10kV及以下绝缘穿刺线夹
Chinese Classification
K10
Professional Classification
DL
ICS Classification
Issued by
National Energy Administration
Issued on
2012-8-23
Implemented on
2012-12-1
Status
superseded
Superseded by
DL/T 1190-2023 Insulation piercing connectors
Superseded on
2024-4-11
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
5000 words
Price(USD)
120.0
Keywords
DL/T 1190-2012, DL 1190-2012, DLT 1190-2012, DL/T1190-2012, DL/T 1190, DL/T1190, DL1190-2012, DL 1190, DL1190, DLT1190-2012, DLT 1190, DLT1190
Introduction of DL/T 1190-2012
1 Scope This standard specifies the technical requirements, tests, inspection rules, marking and packaging of the insulation piercing connector for rated voltages up to 10kV. This standard is applicable to the insulation piercing connectors used for aerial insulated wire, bridge and culvert, adit, tunnel, mineral drive and wire pipe shaft with rated voltage for rated voltage up to 10KV. 2 Normative References The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments to (excluding amending errors in the text), or revisions of, any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to study whether the latest edition of the normative document is applicable. For undated references, the latest edition of the normative document applies. GB/T 2314 General Technical Requirements for Electric Power Fittings GB/T 2317.3 Test Method for Electric Power Fittings - Part 3: Heat Cycle Tests for Electric Power Fittings GB/T 3048.7 Test Methods for Electrical Properties of Electric Cables and Wires - Part 7: Tracking Resistance Test GB/T 12527 Aerial Insulated Cables of Rated Voltage Up to and including 1kV GB/T 14049 Aerial Insulated Cables for Rated Voltage of 10kV GB/T 16927.1 High Voltage Test Techniques - Part 1: General Test Requirements GB/T 16927.2 High Voltage Test Techniques - Part 2: Measuring Systems DL/T 765.1 Technical Requirements for Distribution Fittings DL/T 765.3 Overhead Insulated Conductor Fittings of Rated Voltages Up to 10kv DL/T 768.7 Manufacture Quality Specification for Electric Power Fittings Hot Dip Galvanized Coatings on Fabricated Iron and Steel Articles 3 Terms and Definitions
Contents of DL/T 1190-2012
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Technical Requirements 5 Tests 6 Inspection Rules 7 Marking and Packaging Appendix A (Informative) Installation Requirements Appendix B (Normative) Resistance Test Arrangement and Calculation Appendix C (Normative) Typical Test Loop of Electrical Test Appendix D (Informative) Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
DL/T 1190-2012, DL 1190-2012, DLT 1190-2012, DL/T1190-2012, DL/T 1190, DL/T1190, DL1190-2012, DL 1190, DL1190, DLT1190-2012, DLT 1190, DLT1190