2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/DL/T 507-2002
DL/T 507-2002   Start-up Test Code for Hydraulic-turbine and Generator Units (English Version)
Standard No.: DL/T 507-2002 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 12000 words Translation Price(USD):300.0 remind me the price change

Email:

Implemented on:2002-9-1 Delivery: via email in 1 business day

→ → →

,2014-8-1,2002-9-1,14113738522814D450EB68963A8F4
Standard No.: DL/T 507-2002
English Name: Start-up Test Code for Hydraulic-turbine and Generator Units
Chinese Name: 水轮发电机组启动试验规程
Professional Classification: DL    Professional Standard - Electricity
Source Content Issued by: NDRC
Issued on: 2002-04-27
Implemented on: 2002-9-1
Status: superseded
Superseded by:DL/T 507-2014 Testing Regulations for Hydroelectric Generating Set Start-up
Superseded on:2014-8-1
Target Language: English
File Format: PDF
Word Count: 12000 words
Translation Price(USD): 300.0
Delivery: via email in 1 business day
This professional standard prescribes the start-up operation test procedure and requirement of hydraulic-turbine and generator units with 15MW unit capacity and more than 15MW unit capacity. The standard is applicable for the start-up operation test and acceptance of hydraulic power station hydraulic-turbine and generator units and related electromechanical devices. The units less than 15MW unit capacity can be implemented with reference to this standard. This professional standard is also applicable for the starting test of reversible pump-storage unit power generation working condition. The start-up test requirement of reversible pump-storage unit water pump working condition is implemented according to provisions of GB/T 18482 - 2001 Start-up Test Code for Reversible Pump-storage Units. For the start-up operation test for bulb tubular units, please refer to Start-up Test Code for Bulb Tubular Hydraulic-turbine and Generator Units.
Referred in DL/T 507-2002:
*SDJ 278-1990 Code for design of fire protection of hydraulic engineering
DL/T 507-2002 is referred in:
* GB/T 15468-2006 Fundamental Technical Requirements for Hydraulic Turbines
Code of China
Standard
DL/T 507-2002  Start-up Test Code for Hydraulic-turbine and Generator Units (English Version)
Standard No.DL/T 507-2002
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count12000 words
Price(USD)300.0
Implemented on2002-9-1
Deliveryvia email in 1 business day
Detail of DL/T 507-2002
Standard No.
DL/T 507-2002
English Name
Start-up Test Code for Hydraulic-turbine and Generator Units
Chinese Name
水轮发电机组启动试验规程
Chinese Classification
Professional Classification
DL
ICS Classification
Issued by
NDRC
Issued on
2002-04-27
Implemented on
2002-9-1
Status
superseded
Superseded by
DL/T 507-2014 Testing Regulations for Hydroelectric Generating Set Start-up
Superseded on
2014-8-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
12000 words
Price(USD)
300.0
Keywords
DL/T 507-2002, DL 507-2002, DLT 507-2002, DL/T507-2002, DL/T 507, DL/T507, DL507-2002, DL 507, DL507, DLT507-2002, DLT 507, DLT507
Introduction of DL/T 507-2002
This professional standard prescribes the start-up operation test procedure and requirement of hydraulic-turbine and generator units with 15MW unit capacity and more than 15MW unit capacity. The standard is applicable for the start-up operation test and acceptance of hydraulic power station hydraulic-turbine and generator units and related electromechanical devices. The units less than 15MW unit capacity can be implemented with reference to this standard. This professional standard is also applicable for the starting test of reversible pump-storage unit power generation working condition. The start-up test requirement of reversible pump-storage unit water pump working condition is implemented according to provisions of GB/T 18482 - 2001 Start-up Test Code for Reversible Pump-storage Units. For the start-up operation test for bulb tubular units, please refer to Start-up Test Code for Bulb Tubular Hydraulic-turbine and Generator Units.
Contents of DL/T 507-2002
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
DL/T 507-2002, DL 507-2002, DLT 507-2002, DL/T507-2002, DL/T 507, DL/T507, DL507-2002, DL 507, DL507, DLT507-2002, DLT 507, DLT507