2023-2-1 35.172.230.154
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/DL/T 650-1998
DL/T 650-1998   Specification for potential source static exciter systems for large turbine generators (English Version)
Standard No.: DL/T 650-1998 Status:abolished remind me the status change

Email:

Language:English File Format:PDF
Word Count: 10000 words Price(USD):250.0 remind me the price change

Email:

Implemented on:1998-8-1 Delivery: via email in 1 business day
,,
Standard No.: DL/T 650-1998
English Name: Specification for potential source static exciter systems for large turbine generators
Chinese Name: 大型汽轮发电机自并励静止励磁系统技术条件
Chinese Classification: K54    Steam turbine and its auxiliary equipment
Professional Classification: DL    Professional Standard - Electricity
Issued by: MPI
Issued on: 1998-3-19
Implemented on: 1998-8-1
Status: abolished
Superseded by:DL/T 843-2010 Specification for excitation system for large turbine generators
Superseded on:2010-10-1
Abolished on:2011-05-01
Language: English
File Format: PDF
Word Count: 10000 words
Price(USD): 250.0
Delivery: via email in 1 business day
1 Scope This standard specifies the service conditions, basic performances and test items of potential source static exciter systems for large turbine generators and provides the technical document for customer use as well as the mark, package, transportation, storage and guarantee period on the equipment. This standard is applicable to the potential source static exciter systems for turbine generators in 200MW and above. And for the potential source static exciter systems for turbine generators in less than 200 MW, it shall be implemented as a reference. 2 Normative References The following standards contain provisions which, through reference in this text, constitute provisions of this standard. At time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this code are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. GB 1094-1996 "Power Transformer" GB 3797-89 "Electric-Driving Control gear-Part 2: Electric-Driving Control gear Incorporating Electronic Devices" GB/T 3859 93 "Semiconductor Convertors" GB 4064-83 "General Guide for Designing of Electrical Equipment to Satisfy Safety Requirements" GB 4208-93 "Degrees of Protection Provided by Enclosure (IP Code)" GB 6162-85 "Electrical Interference Test of Static Relay and Protective Devices" GB 6450-86 "Dry-type Power Transformers" GB/T 7064-1996 "Requirements for Turbine Type Synchronous Machine" GB/T 7409-1997 "Excitation System of Synchronous Machine" GB 13926-92 "Electromagnetic Compatibility of Measurement and Control Equipments in Industrial Process" GB 14285-93 "Technical Code for Relaying Protection and Security Automatic Equipment" GB/T 14598.9-1995 "Electrical Relays Part 22: Electrical Disturbance Tests for Measuring Relays and Protection Equipment. Section Three--Radiated Electromagnetic Field Disturbance Tests" GB50150-91 "Standard for Hand-over Test of Electric Equipment Electric Equipment Installation Engineering" JB/T7828-1995 "Specification for Package, Storage and Transportation of Relay and Equipment" DL478-92 "Technical Code for Relaying Protection and Security Automatic Equipment" DL/T596-1996 "The Preventive Test Work for Electric Equipment Regulation" 3 Service Conditions 3.1 Operating ambient 3.1.1 The sea level elevation shall not exceed 1000m. 3.1.2 The maximum ambient temperature shall be 40℃. 3.1.3 The minimum ambient temperature for direct water cooling rectifier shall be 5 ℃ and for the other types of cooling equipments , it shall be-5℃. 3.1.4 The mean monthly maximum relative humidity of the most humid month shall be 90 % and the mean monthly minimum temperature of this month shall not be higher than 25℃. 3.1.5 The air around installation site shall be clean and dry and shall be free from explosion hazard and gas which may corrode metal or destroy the insulation. The installation site of excitation regulating equipment and rectifier shall take measures to prevent dust and to ventilate. 3.1.6 When the vibration frequency is 10 Hz~150 Hz, the oscillating acceleration shall not be greater than 5 m/s2. 3.2 Working power supply conditions The allowable deviation of alternating voltage shall be-15%~+10% of the rated value and the allowable deviation of frequency shall be -6 %~+4 % of the rated value. The DC voltage allowable deviation shall be -20 %~+10 % of the rated value. 3.3 When the operating environment conditions fail to meet the requirements as stated above, the relevant parameters shall be corrected according to the corresponding standard requirements of each part; under special circumstances, it shall be arranged by the demander and supplier.
1 Scope 2 Normative References 3 Service Conditions 4 System Performance 5 Part Performance 6 Test Item 7 Technical Documents 8 Marking, Packing, Transportation and Storage 9 Guarantee Period Appendix A (Normative) Terms
Referred in DL/T 650-1998:
* GB 1094-1996
* GB 3797-1989
* GB/T 3859-
* GB 4064-1983 General guide for designing of electrical equipment to satisfy safety requirements
* GB 4208-1993 Degrees of protection provided by enclosure (IP code)
* GB 6162-1985
* GB 6450-1986 Dry-type power transformers
* GB/T 7064-1996 Requirements for turbine type synchronous machine
* GB/T 7409-1997
* GB 13926-1992
* GB 14285-1993 Technical Code for Relaying Protection and Security Automatic Equipme
* GB/T 14598.9-1995 Electrical relays. Part 22: Electrical disturbance tests for measuring relays and protection equipment. Section three--Radiated electromagnetic field disturbance tests
* GB 50150-1991 Standard for hand-over test of electric equipment electric equipment installation engineering
* JB/T 7828-1995 Technical Specification for Packaging, Storage and Transportation of Relays and Their Accessories
* DL478-1992
* DL/T 596-1996 Preventive Test Code for Electric Power Equipment
DL/T 650-1998 is referred in:
* DL/T 5174-2003 Code for Design of Gas-Steam Combined-cycle Power Plant
* DL/T 843-2003 Specification for A.C exciter rectifier excitation system for large turbine generators
*DL/T 1040-2007 The grid operation code
Code of China
Standard
DL/T 650-1998  Specification for potential source static exciter systems for large turbine generators (English Version)
Standard No.DL/T 650-1998
Statusabolished
LanguageEnglish
File FormatPDF
Word Count10000 words
Price(USD)250.0
Implemented on1998-8-1
Deliveryvia email in 1 business day
Detail of DL/T 650-1998
Standard No.
DL/T 650-1998
English Name
Specification for potential source static exciter systems for large turbine generators
Chinese Name
大型汽轮发电机自并励静止励磁系统技术条件
Chinese Classification
K54
Professional Classification
DL
ICS Classification
Issued by
MPI
Issued on
1998-3-19
Implemented on
1998-8-1
Status
abolished
Superseded by
DL/T 843-2010 Specification for excitation system for large turbine generators
Superseded on
2010-10-1
Abolished on
2011-05-01
Superseding
Language
English
File Format
PDF
Word Count
10000 words
Price(USD)
250.0
Keywords
DL/T 650-1998, DL 650-1998, DLT 650-1998, DL/T650-1998, DL/T 650, DL/T650, DL650-1998, DL 650, DL650, DLT650-1998, DLT 650, DLT650
Introduction of DL/T 650-1998
1 Scope This standard specifies the service conditions, basic performances and test items of potential source static exciter systems for large turbine generators and provides the technical document for customer use as well as the mark, package, transportation, storage and guarantee period on the equipment. This standard is applicable to the potential source static exciter systems for turbine generators in 200MW and above. And for the potential source static exciter systems for turbine generators in less than 200 MW, it shall be implemented as a reference. 2 Normative References The following standards contain provisions which, through reference in this text, constitute provisions of this standard. At time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this code are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. GB 1094-1996 "Power Transformer" GB 3797-89 "Electric-Driving Control gear-Part 2: Electric-Driving Control gear Incorporating Electronic Devices" GB/T 3859 93 "Semiconductor Convertors" GB 4064-83 "General Guide for Designing of Electrical Equipment to Satisfy Safety Requirements" GB 4208-93 "Degrees of Protection Provided by Enclosure (IP Code)" GB 6162-85 "Electrical Interference Test of Static Relay and Protective Devices" GB 6450-86 "Dry-type Power Transformers" GB/T 7064-1996 "Requirements for Turbine Type Synchronous Machine" GB/T 7409-1997 "Excitation System of Synchronous Machine" GB 13926-92 "Electromagnetic Compatibility of Measurement and Control Equipments in Industrial Process" GB 14285-93 "Technical Code for Relaying Protection and Security Automatic Equipment" GB/T 14598.9-1995 "Electrical Relays Part 22: Electrical Disturbance Tests for Measuring Relays and Protection Equipment. Section Three--Radiated Electromagnetic Field Disturbance Tests" GB50150-91 "Standard for Hand-over Test of Electric Equipment Electric Equipment Installation Engineering" JB/T7828-1995 "Specification for Package, Storage and Transportation of Relay and Equipment" DL478-92 "Technical Code for Relaying Protection and Security Automatic Equipment" DL/T596-1996 "The Preventive Test Work for Electric Equipment Regulation" 3 Service Conditions 3.1 Operating ambient 3.1.1 The sea level elevation shall not exceed 1000m. 3.1.2 The maximum ambient temperature shall be 40℃. 3.1.3 The minimum ambient temperature for direct water cooling rectifier shall be 5 ℃ and for the other types of cooling equipments , it shall be-5℃. 3.1.4 The mean monthly maximum relative humidity of the most humid month shall be 90 % and the mean monthly minimum temperature of this month shall not be higher than 25℃. 3.1.5 The air around installation site shall be clean and dry and shall be free from explosion hazard and gas which may corrode metal or destroy the insulation. The installation site of excitation regulating equipment and rectifier shall take measures to prevent dust and to ventilate. 3.1.6 When the vibration frequency is 10 Hz~150 Hz, the oscillating acceleration shall not be greater than 5 m/s2. 3.2 Working power supply conditions The allowable deviation of alternating voltage shall be-15%~+10% of the rated value and the allowable deviation of frequency shall be -6 %~+4 % of the rated value. The DC voltage allowable deviation shall be -20 %~+10 % of the rated value. 3.3 When the operating environment conditions fail to meet the requirements as stated above, the relevant parameters shall be corrected according to the corresponding standard requirements of each part; under special circumstances, it shall be arranged by the demander and supplier.
Contents of DL/T 650-1998
1 Scope 2 Normative References 3 Service Conditions 4 System Performance 5 Part Performance 6 Test Item 7 Technical Documents 8 Marking, Packing, Transportation and Storage 9 Guarantee Period Appendix A (Normative) Terms
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
DL/T 650-1998, DL 650-1998, DLT 650-1998, DL/T650-1998, DL/T 650, DL/T650, DL650-1998, DL 650, DL650, DLT650-1998, DLT 650, DLT650