2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 12021.9-2021
GB 12021.9-2021   Minimum allowable values of energy efficiency and energy efficiency grades for electric fans (English Version)
Standard No.: GB 12021.9-2021 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 4000 words Translation Price(USD):120.0 remind me the price change

Email:

Implemented on:2022-11-1 Delivery: via email in 1~3 business day

→ → →

,,2022-11-1,163395517261500023a488ef24117733
Standard No.: GB 12021.9-2021
English Name: Minimum allowable values of energy efficiency and energy efficiency grades for electric fans
Chinese Name: 电风扇能效限定值及能效等级
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2021-10-11
Implemented on: 2022-11-1
Status: valid
Superseding:GB 12021.9-2008 Minimum allowable values of energy efficiency and energy efficiency grades of AC electric fans
Target Language: English
File Format: PDF
Word Count: 4000 words
Translation Price(USD): 120.0
Delivery: via email in 1~3 business day
This document is developed in accordance with the rules given in GB/T 1.1-2020 Directives for standardization - Part 1: Rules for the structure and drafting of standardizing documents. This document replaces GB 12021.9-2008 Minimum allowable values of energy efficiency and energy efficiency grades of AC electric fans. In addition to main structural adjustments and editorial changes, the following main technical changes have been made with respect to GB 12021.9-2008: a) DC motor-driven electric fans are added (see Clause 1); b) The normative references are adjusted: GB/T 35758-2017 and QB/T 5262-2018 are added, GB/T 2828.1 and GB/T 2829 are deleted (see Clause 2 hereof; Clause 2 of Edition 2008); c) The terms and definitions of the original standard "minimum allowable values of energy efficiency of AC electric fans" and "energy efficiency evaluation value of AC electric fans" are deleted (see 3.1 and 3.2 of Edition 2008); d) The terms and definitions of "energy efficiency for electric fans", "minimum allowable values of energy efficiency for electric fans", "standby power" and "wind gathering fans" have been added (see 3.1, 3.2, 3.3 and 3.4); e) The "basic requirements" and "energy saving evaluation value" in Clause 4 of the original standard are deleted (see 4.1 and 4.4 of Edition 2008); f) The energy efficiency value of each grade is changed (see Table 1 hereof; Table 1 of Edition 2008), the standby power requirements for each grade are added (see Table 2), and the energy efficiency calculation methods for electric fans are added (see 6.2); g) The “inspection rules” in the original standard is deleted (see Clause 6 of Edition 2008); h) Normative annex - "Judgment of wind gathering fans” is added (see Annex A). Minimum allowable values of energy efficiency and energy efficiency grades for electric fans 1 Scope This document specifies the energy efficiency grades, technical requirements, test methods and energy efficiency calculation methods. This document is applicable to table fans, louver fans, wall fans, floor fans, pedestal fans and ceiling fans which are driven by AC or DC motors with single-phase rated voltage not more than 250V and other rated voltages not more than 480V. 2 Normative references The following documents contain provisions which, through reference in this text, constitute indispensable provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 13380-2018 A.C. electric fans and regulators GB/T 35758-2017 Household electrical appliances - Measurement of standby power QB/T 5262-2018 D.C. electric fans 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 13380-2018, GB/T 35758-2017 and QB/T 5262-2018 as well as the following apply. 3.1 energy efficiency for electric fans ratio of output air volume to input power of electric fans 3.2 minimum allowable values of energy efficiency for electric fans minimum allowable energy efficiency value of electric fans under the test conditions specified in the standard, on the premise of meeting the requirements of standby power 3.3 standby power power of the electric fan when it is powered on and in a waiting state (the motor is not working) 3.4 wind gathering fans table fans, wall fans, floor fans and pedestal fans with the ratio of inner ring air volume to outer ring air volume not less than 0.9 4 Energy efficiency grades The energy efficiency for electric fans is classified into three grades, among which Grade 1 is the highest. The energy efficiency value of products of each specification shall meet the requirements of Table 1, and their standby power (if applicable) shall meet the requirements of Table 2. Table 1 Energy efficiency grades for electric fans Type Specification X mm Energy efficiency value m3/(min·W) Energy efficiency grade Grade 1 Grade 2 Grade 3 Table fan, louver fan, wall fan, floor fan and pedestal fan 200 ≥1.00 ≥0.70 ≥0.60 200
Foreword II 1 Scope 2 Normative references 3 Terms and definitions 4 Energy efficiency grades 5 Technical requirements 6 Test methods and energy efficiency calculation methods Annex A (Normative) Judgment of wind gathering fans
Referred in GB 12021.9-2021:
*GB/T 13380-2018 A.C.electric fans and regulators
*GB/T 35758-2017 Household electrical appliances―Measurement of standby power
*QB/T 5262-2018 D.C. electric fans
GB 12021.9-2021 is referred in:
*GB 36893-2024 Minimum allowable values of energy efficiency and energy efficiency grades for air cleaner
Code of China
Standard
GB 12021.9-2021  Minimum allowable values of energy efficiency and energy efficiency grades for electric fans (English Version)
Standard No.GB 12021.9-2021
Statusvalid
LanguageEnglish
File FormatPDF
Word Count4000 words
Price(USD)120.0
Implemented on2022-11-1
Deliveryvia email in 1~3 business day
Detail of GB 12021.9-2021
Standard No.
GB 12021.9-2021
English Name
Minimum allowable values of energy efficiency and energy efficiency grades for electric fans
Chinese Name
电风扇能效限定值及能效等级
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2021-10-11
Implemented on
2022-11-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 12021.9-2008 Minimum allowable values of energy efficiency and energy efficiency grades of AC electric fans
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
120.0
Keywords
GB 12021.9-2021, GB/T 12021.9-2021, GBT 12021.9-2021, GB12021.9-2021, GB 12021.9, GB12021.9, GB/T12021.9-2021, GB/T 12021.9, GB/T12021.9, GBT12021.9-2021, GBT 12021.9, GBT12021.9
Introduction of GB 12021.9-2021
This document is developed in accordance with the rules given in GB/T 1.1-2020 Directives for standardization - Part 1: Rules for the structure and drafting of standardizing documents. This document replaces GB 12021.9-2008 Minimum allowable values of energy efficiency and energy efficiency grades of AC electric fans. In addition to main structural adjustments and editorial changes, the following main technical changes have been made with respect to GB 12021.9-2008: a) DC motor-driven electric fans are added (see Clause 1); b) The normative references are adjusted: GB/T 35758-2017 and QB/T 5262-2018 are added, GB/T 2828.1 and GB/T 2829 are deleted (see Clause 2 hereof; Clause 2 of Edition 2008); c) The terms and definitions of the original standard "minimum allowable values of energy efficiency of AC electric fans" and "energy efficiency evaluation value of AC electric fans" are deleted (see 3.1 and 3.2 of Edition 2008); d) The terms and definitions of "energy efficiency for electric fans", "minimum allowable values of energy efficiency for electric fans", "standby power" and "wind gathering fans" have been added (see 3.1, 3.2, 3.3 and 3.4); e) The "basic requirements" and "energy saving evaluation value" in Clause 4 of the original standard are deleted (see 4.1 and 4.4 of Edition 2008); f) The energy efficiency value of each grade is changed (see Table 1 hereof; Table 1 of Edition 2008), the standby power requirements for each grade are added (see Table 2), and the energy efficiency calculation methods for electric fans are added (see 6.2); g) The “inspection rules” in the original standard is deleted (see Clause 6 of Edition 2008); h) Normative annex - "Judgment of wind gathering fans” is added (see Annex A). Minimum allowable values of energy efficiency and energy efficiency grades for electric fans 1 Scope This document specifies the energy efficiency grades, technical requirements, test methods and energy efficiency calculation methods. This document is applicable to table fans, louver fans, wall fans, floor fans, pedestal fans and ceiling fans which are driven by AC or DC motors with single-phase rated voltage not more than 250V and other rated voltages not more than 480V. 2 Normative references The following documents contain provisions which, through reference in this text, constitute indispensable provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 13380-2018 A.C. electric fans and regulators GB/T 35758-2017 Household electrical appliances - Measurement of standby power QB/T 5262-2018 D.C. electric fans 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 13380-2018, GB/T 35758-2017 and QB/T 5262-2018 as well as the following apply. 3.1 energy efficiency for electric fans ratio of output air volume to input power of electric fans 3.2 minimum allowable values of energy efficiency for electric fans minimum allowable energy efficiency value of electric fans under the test conditions specified in the standard, on the premise of meeting the requirements of standby power 3.3 standby power power of the electric fan when it is powered on and in a waiting state (the motor is not working) 3.4 wind gathering fans table fans, wall fans, floor fans and pedestal fans with the ratio of inner ring air volume to outer ring air volume not less than 0.9 4 Energy efficiency grades The energy efficiency for electric fans is classified into three grades, among which Grade 1 is the highest. The energy efficiency value of products of each specification shall meet the requirements of Table 1, and their standby power (if applicable) shall meet the requirements of Table 2. Table 1 Energy efficiency grades for electric fans Type Specification X mm Energy efficiency value m3/(min·W) Energy efficiency grade Grade 1 Grade 2 Grade 3 Table fan, louver fan, wall fan, floor fan and pedestal fan 200 ≥1.00 ≥0.70 ≥0.60 200
Contents of GB 12021.9-2021
Foreword II 1 Scope 2 Normative references 3 Terms and definitions 4 Energy efficiency grades 5 Technical requirements 6 Test methods and energy efficiency calculation methods Annex A (Normative) Judgment of wind gathering fans
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 12021.9-2021, GB/T 12021.9-2021, GBT 12021.9-2021, GB12021.9-2021, GB 12021.9, GB12021.9, GB/T12021.9-2021, GB/T 12021.9, GB/T12021.9, GBT12021.9-2021, GBT 12021.9, GBT12021.9