2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 18280.1-2015
GB 18280.1-2015   Sterilization of health care products―Radiation―Part 1:Requirements for development,validation and routine control of a sterilization process for medical devices (English Version)
Standard No.: GB 18280.1-2015 Status:to be superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 14500 words Translation Price(USD):140.0 remind me the price change

Email:

Implemented on:2017-7-1 Delivery: via email in 1 business day

→ → →

,2029-1-1,2017-7-1,6CBFEDBCD6B33E301461123575910
Standard No.: GB 18280.1-2015
English Name: Sterilization of health care products―Radiation―Part 1:Requirements for development,validation and routine control of a sterilization process for medical devices
Chinese Name: 医疗保健产品灭菌 辐射 第1部分:医疗器械灭菌过程的开发、确认和常规控制要求
Chinese Classification: C47    Public medical equipment
Professional Classification: GB    National Standard
ICS Classification: 11.080.01 11.080.01    Sterilization and disinfection in general 11.080.01
Source Content Issued by: AQSIQ; MOH
Issued on: 2015-12-31
Implemented on: 2017-7-1
Status: to be superseded
Superseded by:GB 18280.1-2025
Superseded on:2029-1-1
Superseding:GB 18280-2000 Sterilization of health care products—Requirement for validation and routine control—Radiation sterilization
Target Language: English
File Format: PDF
Word Count: 14500 words
Translation Price(USD): 140.0
Delivery: via email in 1 business day
Sterilization of health care products - Radiation - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices 1 Scope 1.1 This part of GB 18280 specifies requirements for the development, validation and routine control of a radiation sterilization process for medical devices. Note: Although the scope of this part is limited to medical devices, it specifies requirements and provides guidance that may be applicable to other products and equipment. This part covers radiation processes employing irradiators using: a) the radionuclide 60Co or 137Cs; b) a beam from an electron generator; c) a beam from an X-ray generator. 1.2 This part of does not specify requirements for development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeld-Jakob disease. Specific recommendations have been produced in particular countries for the processing of materials potentially contaminated with these agents. Examples: ISO 22442-1, ISO 22442-2, and ISO 22442-3. 1.2.1 This part does not detail specified requirements for designating a medical device as sterile. Note: Attention shall be drawn to regional and national requirements for designating medical devices as “sterile.” See, for example, EN 556-1 or ANSI/AAMI ST67. 1.2.2 This part does not specify a quality management system for the control of all stages of production of medical devices. Note: It is not a requirement of this part to have a complete quality management system during manufacture, but the elements of a quality management system that are the minimum necessary to control the sterilization process are normatively referenced at appropriate places in the text (see, in particular, Clause 4). Attention is drawn to the standards for quality management systems (see YY/T 0287) that control all stages of production of medical devices, including the sterilization process. Regional and national regulations for the provision of medical devices might require implementation of a complete quality management system and the assessment of that system by a third party. 1.2.3 This part does not require that biological indicators be used for validation or monitoring of radiation sterilization, nor does it require that a pharmacopoeial test for sterility be carried out for product release. 1.2.4 This part does not specify requirements for occupational safety associated with the design and operation of irradiation facilities. Note: Attention shall also be drawn to the existence, in some countries, of regulations laying down safety requirements for occupational safety related to radiation. 1.2.5 This part does not specify requirements for the sterilization of used or reprocessed devices. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 18280.2-2015 Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose (ISO 11137-2: 2006, IDT) YY/T 0287-2003 Medical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485: 2003, IDT) ISO 10012-1 Quality assurance requirements for measuring equipment - Part 1: Metrological confirmation system for measuring equipment ISO 117373-1 Sterilization of medical devices - Microbiological methods - Part 1: Determination of a population of microorganisms on products ISO 11737-2 Sterilization of medical devices - Microbiological methods - Part 2: Tests of sterility performed in the validation of a sterilization process 3 Terms and definitions For the purposes of this document, the following terms and definitions apply.
Foreword i Introduction 1 Scope 2 Normative references 3 Terms and definitions 4 Quality management system elements 5 Sterilizing agent characterization 6 Process and equipment characterization 7 Product definition 8 Process definition 9 Validation 10 Routine monitoring and control 11 Product release from sterilization 12 Maintaining process effectiveness Annex A (Informative) Guidance Bibliography
GB 18280.1-2015 is referred in:
*GB 18280.2-2015 Sterilization of health care products―Radiation―Part 2:Establishing the sterilization dose
*GB 9706.1-2020 Medical electrical equipment—Part 1: General requirements for basic safety and essential performance
*YY/T 1739-2020 Cardiopulmonary bypass systems—Centrifugal pump-head
*YY/T 1737-2020 Analytical method for bioburden control level of medical device
*YY 0585.2-2019 Fluid lines for use with pressure infusion equipment and accessories for single use—Part 2:Accessories
*YY/T 0286.4-2020 Special infusion sets—Part 4:Infusion sets for single use with pressure infusion apparatus
*YY 0861-2024 Ophthalmic optics—Ophthalmic viscosurgical devices
*GB 18281.1-2015 Sterilization of health care products—Biological indicators—Part 1: General requirements
Code of China
Standard
GB 18280.1-2015  Sterilization of health care products―Radiation―Part 1:Requirements for development,validation and routine control of a sterilization process for medical devices (English Version)
Standard No.GB 18280.1-2015
Statusto be superseded
LanguageEnglish
File FormatPDF
Word Count14500 words
Price(USD)140.0
Implemented on2017-7-1
Deliveryvia email in 1 business day
Detail of GB 18280.1-2015
Standard No.
GB 18280.1-2015
English Name
Sterilization of health care products―Radiation―Part 1:Requirements for development,validation and routine control of a sterilization process for medical devices
Chinese Name
医疗保健产品灭菌 辐射 第1部分:医疗器械灭菌过程的开发、确认和常规控制要求
Chinese Classification
C47
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; MOH
Issued on
2015-12-31
Implemented on
2017-7-1
Status
to be superseded
Superseded by
GB 18280.1-2025
Superseded on
2029-1-1
Abolished on
Superseding
GB 18280-2000 Sterilization of health care products—Requirement for validation and routine control—Radiation sterilization
Language
English
File Format
PDF
Word Count
14500 words
Price(USD)
140.0
Keywords
GB 18280.1-2015, GB/T 18280.1-2015, GBT 18280.1-2015, GB18280.1-2015, GB 18280.1, GB18280.1, GB/T18280.1-2015, GB/T 18280.1, GB/T18280.1, GBT18280.1-2015, GBT 18280.1, GBT18280.1
Introduction of GB 18280.1-2015
Sterilization of health care products - Radiation - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices 1 Scope 1.1 This part of GB 18280 specifies requirements for the development, validation and routine control of a radiation sterilization process for medical devices. Note: Although the scope of this part is limited to medical devices, it specifies requirements and provides guidance that may be applicable to other products and equipment. This part covers radiation processes employing irradiators using: a) the radionuclide 60Co or 137Cs; b) a beam from an electron generator; c) a beam from an X-ray generator. 1.2 This part of does not specify requirements for development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeld-Jakob disease. Specific recommendations have been produced in particular countries for the processing of materials potentially contaminated with these agents. Examples: ISO 22442-1, ISO 22442-2, and ISO 22442-3. 1.2.1 This part does not detail specified requirements for designating a medical device as sterile. Note: Attention shall be drawn to regional and national requirements for designating medical devices as “sterile.” See, for example, EN 556-1 or ANSI/AAMI ST67. 1.2.2 This part does not specify a quality management system for the control of all stages of production of medical devices. Note: It is not a requirement of this part to have a complete quality management system during manufacture, but the elements of a quality management system that are the minimum necessary to control the sterilization process are normatively referenced at appropriate places in the text (see, in particular, Clause 4). Attention is drawn to the standards for quality management systems (see YY/T 0287) that control all stages of production of medical devices, including the sterilization process. Regional and national regulations for the provision of medical devices might require implementation of a complete quality management system and the assessment of that system by a third party. 1.2.3 This part does not require that biological indicators be used for validation or monitoring of radiation sterilization, nor does it require that a pharmacopoeial test for sterility be carried out for product release. 1.2.4 This part does not specify requirements for occupational safety associated with the design and operation of irradiation facilities. Note: Attention shall also be drawn to the existence, in some countries, of regulations laying down safety requirements for occupational safety related to radiation. 1.2.5 This part does not specify requirements for the sterilization of used or reprocessed devices. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 18280.2-2015 Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose (ISO 11137-2: 2006, IDT) YY/T 0287-2003 Medical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485: 2003, IDT) ISO 10012-1 Quality assurance requirements for measuring equipment - Part 1: Metrological confirmation system for measuring equipment ISO 117373-1 Sterilization of medical devices - Microbiological methods - Part 1: Determination of a population of microorganisms on products ISO 11737-2 Sterilization of medical devices - Microbiological methods - Part 2: Tests of sterility performed in the validation of a sterilization process 3 Terms and definitions For the purposes of this document, the following terms and definitions apply.
Contents of GB 18280.1-2015
Foreword i Introduction 1 Scope 2 Normative references 3 Terms and definitions 4 Quality management system elements 5 Sterilizing agent characterization 6 Process and equipment characterization 7 Product definition 8 Process definition 9 Validation 10 Routine monitoring and control 11 Product release from sterilization 12 Maintaining process effectiveness Annex A (Informative) Guidance Bibliography