2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 18281.2-2015
GB 18281.2-2015   Sterilization of health care products―Biological indicators―Part 2:Biological indicators for ethylene oxide sterilization processes (English Version)
Standard No.: GB 18281.2-2015 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5500 words Translation Price(USD):80.0 remind me the price change

Email:

Implemented on:2017-1-1 Delivery: via email in 1 business day

→ → →

,2025-12-1,2017-1-1,73F48EEA9218E39C1451542208958
Standard No.: GB 18281.2-2015
English Name: Sterilization of health care products―Biological indicators―Part 2:Biological indicators for ethylene oxide sterilization processes
Chinese Name: 医疗保健产品灭菌 生物指示物 第2部分:环氧乙烷灭菌用生物指示物
Chinese Classification: C47    Public medical equipment
Professional Classification: GB    National Standard
ICS Classification: 11.080.01 11.080.01    Sterilization and disinfection in general 11.080.01
Source Content Issued by: AQSIQ; MOH
Issued on: 2015-12-10
Implemented on: 2017-1-1
Status: superseded
Superseded by:GB/T 18281.2-2024 Sterilization of health care products—Biological indicators—Part 2: Biological indicators for ethylene oxide sterilization processes
Superseded on:2025-12-1
Superseding:GB 18281.2-2000 Sterilization of health care products - Biological indicators - Part 2: Biological indicators for ethylene oxide sterilization
Target Language: English
File Format: PDF
Word Count: 5500 words
Translation Price(USD): 80.0
Delivery: via email in 1 business day
GB 18281.2-2015 Sterilization of health care products - Biological indicators Part 2: Biological indicators for ethylene oxide sterilization processes 1 Scope This part of GB 18281 provides specific requirements for test organisms, suspensions, inoculated carriers, biological indicators and test methods intended for use in assessing the performance of sterilizers and sterilization processes employing ethylene oxide gas as the sterilizing agent, either as pure ethylene oxide gas or mixtures of this gas with diluent gases, at sterilizing temperatures within the range of 29 ℃ to 65 ℃. Note 1: Requirements for validation and control of ethylene oxide sterilization processes are provided by GB 18279. Note 2: National or regional regulations could provide requirements for work place safety. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 11138-1:2006 Sterilization of health care products - Biological indicators - Part 1: General requirements ISO 18472 Sterilization of health care products - Biological and chemical indicators - Test equipment 3 Term and definition For the purposes of this document, the terms and definitions given in ISO 11138-1 apply. 4 General requirements The requirements of ISO 11138-1 apply. 5 Test organism 5.1 The test organisms shall be spores of Bacillus atrophaeus, Bacillus subtilis or other strains of microorganisms of demonstrated equivalent performance as required by this standard. Note 1: Some strains of Bacillus subtilis have been reclassified as Bacillus atrophaeus. Note 2: Bacillus atrophaeus ATCC 9372, NCTC 10073, NCIMB 8058, DSM 2277, NRRL B-4418 and CIP 77.18 have been found to be suitable. 5.2 If a test organism other than Bacillus atrophaeus is used, the suitability of the resistance of that test organism shall be determined.
Foreword I Introduction III 1 Scope 2 Normative references 3 Term and definition 4 General requirements 5 Test organism 6 Suspension 7 Carrier and primary packaging 8 Inoculated carriers and biological indicators 9 Population and resistance Annex A (Normative) Method for determination of resistance to ethylene oxide sterilization Bibliography
GB 18281.2-2015 is referred in:
*GB 18279.1-2015 Sterilization of health care products―Ethylene oxide―Part 1:Requirements for development,validation and routine control of a sterilization process for medical devices
*GB 18279-2023 Sterilization of health-care products—Ethylene oxide—Requirements for the development,validation and routine control of a sterilization process for medical devices
*YY/T 1623-2018 Test method of effectiveness of sterilization processes for reusable medical devices
Code of China
Standard
GB 18281.2-2015  Sterilization of health care products―Biological indicators―Part 2:Biological indicators for ethylene oxide sterilization processes (English Version)
Standard No.GB 18281.2-2015
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count5500 words
Price(USD)80.0
Implemented on2017-1-1
Deliveryvia email in 1 business day
Detail of GB 18281.2-2015
Standard No.
GB 18281.2-2015
English Name
Sterilization of health care products―Biological indicators―Part 2:Biological indicators for ethylene oxide sterilization processes
Chinese Name
医疗保健产品灭菌 生物指示物 第2部分:环氧乙烷灭菌用生物指示物
Chinese Classification
C47
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; MOH
Issued on
2015-12-10
Implemented on
2017-1-1
Status
superseded
Superseded by
GB/T 18281.2-2024 Sterilization of health care products—Biological indicators—Part 2: Biological indicators for ethylene oxide sterilization processes
Superseded on
2025-12-1
Abolished on
Superseding
GB 18281.2-2000 Sterilization of health care products - Biological indicators - Part 2: Biological indicators for ethylene oxide sterilization
Language
English
File Format
PDF
Word Count
5500 words
Price(USD)
80.0
Keywords
GB 18281.2-2015, GB/T 18281.2-2015, GBT 18281.2-2015, GB18281.2-2015, GB 18281.2, GB18281.2, GB/T18281.2-2015, GB/T 18281.2, GB/T18281.2, GBT18281.2-2015, GBT 18281.2, GBT18281.2
Introduction of GB 18281.2-2015
GB 18281.2-2015 Sterilization of health care products - Biological indicators Part 2: Biological indicators for ethylene oxide sterilization processes 1 Scope This part of GB 18281 provides specific requirements for test organisms, suspensions, inoculated carriers, biological indicators and test methods intended for use in assessing the performance of sterilizers and sterilization processes employing ethylene oxide gas as the sterilizing agent, either as pure ethylene oxide gas or mixtures of this gas with diluent gases, at sterilizing temperatures within the range of 29 ℃ to 65 ℃. Note 1: Requirements for validation and control of ethylene oxide sterilization processes are provided by GB 18279. Note 2: National or regional regulations could provide requirements for work place safety. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 11138-1:2006 Sterilization of health care products - Biological indicators - Part 1: General requirements ISO 18472 Sterilization of health care products - Biological and chemical indicators - Test equipment 3 Term and definition For the purposes of this document, the terms and definitions given in ISO 11138-1 apply. 4 General requirements The requirements of ISO 11138-1 apply. 5 Test organism 5.1 The test organisms shall be spores of Bacillus atrophaeus, Bacillus subtilis or other strains of microorganisms of demonstrated equivalent performance as required by this standard. Note 1: Some strains of Bacillus subtilis have been reclassified as Bacillus atrophaeus. Note 2: Bacillus atrophaeus ATCC 9372, NCTC 10073, NCIMB 8058, DSM 2277, NRRL B-4418 and CIP 77.18 have been found to be suitable. 5.2 If a test organism other than Bacillus atrophaeus is used, the suitability of the resistance of that test organism shall be determined.
Contents of GB 18281.2-2015
Foreword I Introduction III 1 Scope 2 Normative references 3 Term and definition 4 General requirements 5 Test organism 6 Suspension 7 Carrier and primary packaging 8 Inoculated carriers and biological indicators 9 Population and resistance Annex A (Normative) Method for determination of resistance to ethylene oxide sterilization Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 18281.2-2015, GB/T 18281.2-2015, GBT 18281.2-2015, GB18281.2-2015, GB 18281.2, GB18281.2, GB/T18281.2-2015, GB/T 18281.2, GB/T18281.2, GBT18281.2-2015, GBT 18281.2, GBT18281.2