GB 19761-2020   Minimum allowable values of energy efficiency and energy efficiency grades for fan (English Version)
Standard No.: GB 19761-2020 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5500 words Translation Price(USD):140.0 remind me the price change

Email:

Implemented on:2021-6-1 Delivery: via email in 1~3 business day

→ → →

,,2021-6-1,BB6CCFA36A62CD3C1591243058000
Standard No.: GB 19761-2020
English Name: Minimum allowable values of energy efficiency and energy efficiency grades for fan
Chinese Name: 通风机能效限定值及能效等级
Chinese Classification: F01    Technical management
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2020-05-29
Implemented on: 2021-6-1
Status: valid
Superseding:GB 19761-2009 Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Fan
Target Language: English
File Format: PDF
Word Count: 5500 words
Translation Price(USD): 140.0
Delivery: via email in 1~3 business day
1 Scope This standard specifies the energy efficiency grades, minimum allowable values of energy efficiency, test methods and technical requirements for fan. This standard applies to centrifugal fans for general use, axial fans for general use, centrifugal induced draft fans for industrial boilers, centrifugal fans for power station boilers, axial fans for power stations, centrifugal fans for HVAC and forward multi-wing centrifugal fans. This standard does not apply to duct type fans for AC, box type fans, centrifugal fans without volute and fans with special structures or for other uses. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 1236 Industrial fan - Performance testing using standardized airways GB/T 3235 Basic types sizes parameters and characteristics curve of fans GB/T10178 Industrial fans - performance testing in situ JB/T 2977 Technical terms for industry fans, turbo-blowers and compressors JB/T 4357 Centrifugal ID - fan for industry boiler JB/T 4358 Centrifugal fan for boiler of power station JB/T 4362 Power station axial fans JB/T 7221 Centrifugal fan for heating ventilation and air conditioner JB/T 9068 Forward curved centrifugal fan JB/T 10562 Technical specification for general purposes axial fans JB/T 10563 Technical specification for general purposes centrifugal fans 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 1236, GB/T 3235 and JB/T 2977 and the following apply. 3.1 minimum allowable values of energy efficiency for fan minimum allowable guaranteed value of efficiency for fan under the test conditions specified in the standard 3.2 plant device consisting of a driver and a fan 4 Energy efficiency grade The energy efficiency of a fan is classified into 3 grades, among which Grade 1 represents the highest energy efficiency, while Grade 3 represents the lowest. The requirements are as follows: a) Centrifugal fan 1) The maximum fan efficiency ηr in stable working area shall not be lower than those specified in Table 1 and Table 2; 2) The maximum fan efficiency of centrifugal fans of common motor direct connection type (type A drive) in stable working area shall not be lower than those specified in Table 1 and Table 2; 3) The efficiency ηr of double-suction centrifugal fan in stable working area shall be reduced by 1 percentage point for Grades 1 and 2 according to those specified in Table 1 and Table 2, and by 3 percentage points for Grade 3; 4) The efficiency ηr of HVAC in stable working area shall be reduced by 1 percentage point for Grades 1 and 2 according to those specified in Table 1 and Table 2, and by 3 percentage points for Grade 3; 5) When there is an inlet box at the inlet, the efficiency ηr for each grade in stable working area shall be reduced by 4 percentage points according to those specified in Table 1 and Table 2; 6) For the forward multi-wing centrifugal fan with external rotor motor (except single-phase and three-phase multi-speed type, three-phase six-pole or above), the maximum unit efficiency shall not be lower than those specified in Table 4. b) Axial fan 1) The maximum fan efficiency in stable working area shall not be lower than those specified in Table 3; 2) The maximum efficiency of centrifugal fans of common motor direct connection type (type A drive) in stable working area shall not be lower than those specified in Table 3; 3) When there is an inlet box at the inlet, it shall be reduced by 3 percentage points according to those specified in Table 3; 4) When the outlet is equipped with diffuser, the efficiency value shall not be lower than the provisions in Table 3 that 0.55<γ<0.75, and the machine number > No10. When there is no diffuser at the outlet of the fan, the efficiency value shall be increased by 2 percentage points from those in Table 3. 5) For axial fans with adjustable moving blades (synchronous adjustment of moving blade angle completed in operation), the efficiency value shall be not less than 89.5% for Grade 1, 87% for Grade 2 and 82% for Grade 3, under the condition that there is no inlet box at the inlet and no diffuser at the outlet; 6) For reversible axial fan, the efficiency value shall be reduced by 8 percentage points according to those specified in Table 3.
GB 19761-2020 is referred in:
*GB/T 41013-2021 Evaluation of energy performance of motor system
Code of China
Standard
GB 19761-2020  Minimum allowable values of energy efficiency and energy efficiency grades for fan (English Version)
Standard No.GB 19761-2020
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5500 words
Price(USD)140.0
Implemented on2021-6-1
Deliveryvia email in 1~3 business day
Detail of GB 19761-2020
Standard No.
GB 19761-2020
English Name
Minimum allowable values of energy efficiency and energy efficiency grades for fan
Chinese Name
通风机能效限定值及能效等级
Chinese Classification
F01
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2020-05-29
Implemented on
2021-6-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 19761-2009 Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Fan
Language
English
File Format
PDF
Word Count
5500 words
Price(USD)
140.0
Keywords
GB 19761-2020, GB/T 19761-2020, GBT 19761-2020, GB19761-2020, GB 19761, GB19761, GB/T19761-2020, GB/T 19761, GB/T19761, GBT19761-2020, GBT 19761, GBT19761
Introduction of GB 19761-2020
1 Scope This standard specifies the energy efficiency grades, minimum allowable values of energy efficiency, test methods and technical requirements for fan. This standard applies to centrifugal fans for general use, axial fans for general use, centrifugal induced draft fans for industrial boilers, centrifugal fans for power station boilers, axial fans for power stations, centrifugal fans for HVAC and forward multi-wing centrifugal fans. This standard does not apply to duct type fans for AC, box type fans, centrifugal fans without volute and fans with special structures or for other uses. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 1236 Industrial fan - Performance testing using standardized airways GB/T 3235 Basic types sizes parameters and characteristics curve of fans GB/T10178 Industrial fans - performance testing in situ JB/T 2977 Technical terms for industry fans, turbo-blowers and compressors JB/T 4357 Centrifugal ID - fan for industry boiler JB/T 4358 Centrifugal fan for boiler of power station JB/T 4362 Power station axial fans JB/T 7221 Centrifugal fan for heating ventilation and air conditioner JB/T 9068 Forward curved centrifugal fan JB/T 10562 Technical specification for general purposes axial fans JB/T 10563 Technical specification for general purposes centrifugal fans 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 1236, GB/T 3235 and JB/T 2977 and the following apply. 3.1 minimum allowable values of energy efficiency for fan minimum allowable guaranteed value of efficiency for fan under the test conditions specified in the standard 3.2 plant device consisting of a driver and a fan 4 Energy efficiency grade The energy efficiency of a fan is classified into 3 grades, among which Grade 1 represents the highest energy efficiency, while Grade 3 represents the lowest. The requirements are as follows: a) Centrifugal fan 1) The maximum fan efficiency ηr in stable working area shall not be lower than those specified in Table 1 and Table 2; 2) The maximum fan efficiency of centrifugal fans of common motor direct connection type (type A drive) in stable working area shall not be lower than those specified in Table 1 and Table 2; 3) The efficiency ηr of double-suction centrifugal fan in stable working area shall be reduced by 1 percentage point for Grades 1 and 2 according to those specified in Table 1 and Table 2, and by 3 percentage points for Grade 3; 4) The efficiency ηr of HVAC in stable working area shall be reduced by 1 percentage point for Grades 1 and 2 according to those specified in Table 1 and Table 2, and by 3 percentage points for Grade 3; 5) When there is an inlet box at the inlet, the efficiency ηr for each grade in stable working area shall be reduced by 4 percentage points according to those specified in Table 1 and Table 2; 6) For the forward multi-wing centrifugal fan with external rotor motor (except single-phase and three-phase multi-speed type, three-phase six-pole or above), the maximum unit efficiency shall not be lower than those specified in Table 4. b) Axial fan 1) The maximum fan efficiency in stable working area shall not be lower than those specified in Table 3; 2) The maximum efficiency of centrifugal fans of common motor direct connection type (type A drive) in stable working area shall not be lower than those specified in Table 3; 3) When there is an inlet box at the inlet, it shall be reduced by 3 percentage points according to those specified in Table 3; 4) When the outlet is equipped with diffuser, the efficiency value shall not be lower than the provisions in Table 3 that 0.55<γ<0.75, and the machine number > No10. When there is no diffuser at the outlet of the fan, the efficiency value shall be increased by 2 percentage points from those in Table 3. 5) For axial fans with adjustable moving blades (synchronous adjustment of moving blade angle completed in operation), the efficiency value shall be not less than 89.5% for Grade 1, 87% for Grade 2 and 82% for Grade 3, under the condition that there is no inlet box at the inlet and no diffuser at the outlet; 6) For reversible axial fan, the efficiency value shall be reduced by 8 percentage points according to those specified in Table 3.
Contents of GB 19761-2020
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 19761-2020, GB/T 19761-2020, GBT 19761-2020, GB19761-2020, GB 19761, GB19761, GB/T19761-2020, GB/T 19761, GB/T19761, GBT19761-2020, GBT 19761, GBT19761