2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 27897-2025
GB 27897-2025   Class A foam extinguishing agent (English Version)
Standard No.: GB 27897-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 11000 words Translation Price(USD):330.0 remind me the price change

Email:

Implemented on:2026-11-1 Delivery: via email in 1~5 business day

→ → →

,,2026-11-1,7B00C777838EC8161762263306491
Standard No.: GB 27897-2025
English Name: Class A foam extinguishing agent
Chinese Name: A类泡沫灭火剂
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2025-10-31
Implemented on: 2026-11-1
Status: to be valid
Superseding:GB 27897-2011 Class A foam extinguishing agent
Target Language: English
File Format: PDF
Word Count: 11000 words
Translation Price(USD): 330.0
Delivery: via email in 1~5 business day
GB 27897-2025 Class A foam extinguishing agent English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 13.220 CCS H 57 National Standard of the People's Republic of China ‌GB 27897-2025 Class A foam extinguishing agent A类泡沫灭火剂 Issue date: 2025-10-31 Implementation date: 2026-05-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative References 3 Terms and Definitions 4 Model Designation 5 Requirements 5.1 General Requirements 5.2 Technical Requirements 6 Test Methods 6.1 Sampling and Temperature Treatment 6.2 Freezing Point 6.3 Freeze-Thaw Stability 6.4 Viscosity 6.5 pH Value 6.6 Corrosion Rate 6.7 Surface Tension 6.8 Wetting Ability 6.9 Expansion Ratio and 25% Drainage Time 6.10 Thermal Protection Performance 6.11 Class A Fire Extinguishing Performance 7 Inspection Rules 8 Marking, Packaging, Transportation and Storage Appendix A (Normative) Standard Compressed Air Foam System Operation Method 1 Scope This document specifies the product models, technical requirements, test methods, inspection rules, and marking, packaging, transportation, and storage of Class A foam extinguishing agents. This document is applicable to the research, production, and inspection of Class A foam extinguishing agents. 2 Normative References The following documents contain provisions which, through reference in this text, constitute essential provisions of this document. For dated references, only the edition cited applies; for undated references, the latest version (including amendments) applies. GB/T 2909—2025 Plain Cotton Canvas GB 4351—2023 Portable Fire Extinguishers GB/T 6003.1—2022 Test Sieves—Technical Requirements and Testing—Part 1: Test Sieves with Wire Cloth GB/T 6682 Specification and Test Methods for Water for Laboratory Use GB/T 11983 Surfactants—Determination of Wetting Power—Immersion Method GB/T 21059 Plastics—Polymer/Resin in Liquid or Liquid Dispersion—Determination of Viscosity at a Given Shear Rate Using a Rotational Viscometer 3 Terms and Definitions The following terms and definitions apply to this document. 3.1 Class A foam extinguishing agent A foam extinguishing agent used for extinguishing Class A fires and providing thermal protection. 3.2 Characteristic value Physical and chemical performance parameters of foam concentrate and foam solution proposed by the manufacturer. 3.3 Foam concentrate A concentrated liquid that forms a foam solution when mixed with water in an appropriate proportion. 3.4 Foam solution A solution prepared by mixing foam concentrate with water at a specified proportion. 3.5 25% drainage time The time required for 25% of the liquid mass to drain from the foam. 3.6 Expansion ratio The ratio of the volume of foam to the volume of foam solution used to produce it. 3.7 Mixing proportion The volume fraction of foam concentrate in the foam solution when mixed with water. 3.8 Lowest useful temperature A temperature 5°C above the freezing point. 3.9 Compressed air foam systems Foam generation systems that introduce a controlled amount of air into the foam solution to produce foams with varying expansion ratios and states. 4 Model Designation The model designation for Class A foam extinguishing agents is: MJAP (freezing point characteristic value)-seawater resistant (manufacturer-defined). Example 1: MJAP(-10°C)-seawater resistant, indicating a Class A foam extinguishing agent suitable for freshwater and seawater, with a freezing point of -10°C. Example 2: MJAP(-15°C), indicating a Class A foam extinguishing agent suitable for freshwater only, with a freezing point of -15°C. 5 Requirements 5.1 General Requirements Manufacturers shall declare the following for their Class A foam extinguishing agent products: a) Product model. b) Susceptibility to freezing/thawing. c) Temperature sensitivity of the foam concentrate. d) Water compatibility: suitable for freshwater, or both freshwater and seawater. e) Freezing point characteristic value: T (°C). f) Characteristic values for extinguishing Class A fires. Mixing proportion characteristic value: Code HA, HA shall not exceed 0.5%. 25% drainage time characteristic value: Code tA (min). Expansion ratio characteristic value: Code FA. g) Mixing proportion characteristic value for thermal protection: Code HG, HG shall not exceed 1.0%. 5.2 Technical Requirements 5.2.1 The performance of Class A foam extinguishing agent concentrate shall comply with the requirements of Table 1. Table 1 Performance Requirements for Class A Foam Extinguishing Agent Concentrate 6 Test Methods 6.1 Sampling and Temperature Treatment 6.1.1 Sampling When sampling from the product packaging containers of Class A foam extinguishing agent, the contents shall be thoroughly mixed. The sample quantity for temperature treatment in accordance with 6.1.2 shall be no less than 5 kg, and the sample shall completely fill the storage container and be sealed.
Code of China
Standard
GB 27897-2025  Class A foam extinguishing agent (English Version)
Standard No.GB 27897-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count11000 words
Price(USD)330.0
Implemented on2026-11-1
Deliveryvia email in 1~5 business day
Detail of GB 27897-2025
Standard No.
GB 27897-2025
English Name
Class A foam extinguishing agent
Chinese Name
A类泡沫灭火剂
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-10-31
Implemented on
2026-11-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB 27897-2011 Class A foam extinguishing agent
Language
English
File Format
PDF
Word Count
11000 words
Price(USD)
330.0
Keywords
GB 27897-2025, GB/T 27897-2025, GBT 27897-2025, GB27897-2025, GB 27897, GB27897, GB/T27897-2025, GB/T 27897, GB/T27897, GBT27897-2025, GBT 27897, GBT27897
Introduction of GB 27897-2025
GB 27897-2025 Class A foam extinguishing agent English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 13.220 CCS H 57 National Standard of the People's Republic of China ‌GB 27897-2025 Class A foam extinguishing agent A类泡沫灭火剂 Issue date: 2025-10-31 Implementation date: 2026-05-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative References 3 Terms and Definitions 4 Model Designation 5 Requirements 5.1 General Requirements 5.2 Technical Requirements 6 Test Methods 6.1 Sampling and Temperature Treatment 6.2 Freezing Point 6.3 Freeze-Thaw Stability 6.4 Viscosity 6.5 pH Value 6.6 Corrosion Rate 6.7 Surface Tension 6.8 Wetting Ability 6.9 Expansion Ratio and 25% Drainage Time 6.10 Thermal Protection Performance 6.11 Class A Fire Extinguishing Performance 7 Inspection Rules 8 Marking, Packaging, Transportation and Storage Appendix A (Normative) Standard Compressed Air Foam System Operation Method 1 Scope This document specifies the product models, technical requirements, test methods, inspection rules, and marking, packaging, transportation, and storage of Class A foam extinguishing agents. This document is applicable to the research, production, and inspection of Class A foam extinguishing agents. 2 Normative References The following documents contain provisions which, through reference in this text, constitute essential provisions of this document. For dated references, only the edition cited applies; for undated references, the latest version (including amendments) applies. GB/T 2909—2025 Plain Cotton Canvas GB 4351—2023 Portable Fire Extinguishers GB/T 6003.1—2022 Test Sieves—Technical Requirements and Testing—Part 1: Test Sieves with Wire Cloth GB/T 6682 Specification and Test Methods for Water for Laboratory Use GB/T 11983 Surfactants—Determination of Wetting Power—Immersion Method GB/T 21059 Plastics—Polymer/Resin in Liquid or Liquid Dispersion—Determination of Viscosity at a Given Shear Rate Using a Rotational Viscometer 3 Terms and Definitions The following terms and definitions apply to this document. 3.1 Class A foam extinguishing agent A foam extinguishing agent used for extinguishing Class A fires and providing thermal protection. 3.2 Characteristic value Physical and chemical performance parameters of foam concentrate and foam solution proposed by the manufacturer. 3.3 Foam concentrate A concentrated liquid that forms a foam solution when mixed with water in an appropriate proportion. 3.4 Foam solution A solution prepared by mixing foam concentrate with water at a specified proportion. 3.5 25% drainage time The time required for 25% of the liquid mass to drain from the foam. 3.6 Expansion ratio The ratio of the volume of foam to the volume of foam solution used to produce it. 3.7 Mixing proportion The volume fraction of foam concentrate in the foam solution when mixed with water. 3.8 Lowest useful temperature A temperature 5°C above the freezing point. 3.9 Compressed air foam systems Foam generation systems that introduce a controlled amount of air into the foam solution to produce foams with varying expansion ratios and states. 4 Model Designation The model designation for Class A foam extinguishing agents is: MJAP (freezing point characteristic value)-seawater resistant (manufacturer-defined). Example 1: MJAP(-10°C)-seawater resistant, indicating a Class A foam extinguishing agent suitable for freshwater and seawater, with a freezing point of -10°C. Example 2: MJAP(-15°C), indicating a Class A foam extinguishing agent suitable for freshwater only, with a freezing point of -15°C. 5 Requirements 5.1 General Requirements Manufacturers shall declare the following for their Class A foam extinguishing agent products: a) Product model. b) Susceptibility to freezing/thawing. c) Temperature sensitivity of the foam concentrate. d) Water compatibility: suitable for freshwater, or both freshwater and seawater. e) Freezing point characteristic value: T (°C). f) Characteristic values for extinguishing Class A fires. Mixing proportion characteristic value: Code HA, HA shall not exceed 0.5%. 25% drainage time characteristic value: Code tA (min). Expansion ratio characteristic value: Code FA. g) Mixing proportion characteristic value for thermal protection: Code HG, HG shall not exceed 1.0%. 5.2 Technical Requirements 5.2.1 The performance of Class A foam extinguishing agent concentrate shall comply with the requirements of Table 1. Table 1 Performance Requirements for Class A Foam Extinguishing Agent Concentrate 6 Test Methods 6.1 Sampling and Temperature Treatment 6.1.1 Sampling When sampling from the product packaging containers of Class A foam extinguishing agent, the contents shall be thoroughly mixed. The sample quantity for temperature treatment in accordance with 6.1.2 shall be no less than 5 kg, and the sample shall completely fill the storage container and be sealed.
Contents of GB 27897-2025
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 27897-2025, GB/T 27897-2025, GBT 27897-2025, GB27897-2025, GB 27897, GB27897, GB/T27897-2025, GB/T 27897, GB/T27897, GBT27897-2025, GBT 27897, GBT27897