2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 31604.37-2016
GB 31604.37-2016   National Food Safety Standard - Food Contact Materials and Articles -Determination of Triethylamine and Tributylamine (English Version)
Standard No.: GB 31604.37-2016 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 2000 words Translation Price(USD):40.0 remind me the price change

Email:

Implemented on:2017-4-19 Delivery: via email in 1 business day

→ → →

,,2017-4-19,85E50257630A54AA1479883157031
Standard No.: GB 31604.37-2016
English Name: National Food Safety Standard - Food Contact Materials and Articles -Determination of Triethylamine and Tributylamine
Chinese Name: 食品安全国家标准 食品接触材料及制品 三乙胺和三正丁胺的测定
Professional Classification: GB    National Standard
Source Content Issued by: National Health and Family Planning Commission
Issued on: 2016-10-19
Implemented on: 2017-4-19
Status: valid
Superseding:SN/T 2890-2011 Food contact materials for export-Polymers---Determination of triethylamine and tributylamine in polycarbonate resinand its products-Gas chromatography
Target Language: English
File Format: PDF
Word Count: 2000 words
Translation Price(USD): 40.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard replaces SN/T 2890-2011 Food Contact Materials for Export - Polymers - Determination of Triethylamine and Tributylamine in Polycarbonate Resin and Its Products - Gas Chromatography. The following main changes have been made with respect to SN/T 2890-2011 (the previous edition): ——This standard is renamed as "National Food Safety Standard - Food Contact Materials and Articles - Determination of Triethylamine and Tributylamine". ——The requirement of "plastic containers and transfer appliances shall not be used in the test" is added; ——"Measuring cylinder with stopper" in former standard is changed into "graduated centrifuge tube with stopper". National Food Safety Standard Food Contact Materials and Articles Determination of Triethylamine and Tributylamine 1 Scope This standard specifies the gas chromatography for the determination of the contents of triethylamine and tributylamine in food contact materials and articles. This standard is applicable to the determination of triethylamine and tributylamine in polycarbonate food contact materials and articles. 2 Principle After dissolving the sample with dichloromethane, add in acetone to precipitate the polymer resin; after concentration and scaling of the volume, carry out determination by gas chromatography and quantative determination by external standard method. 3 Reagents and Materials Unless otherwise specified, analytically-pure reagents are adopted for the purpose of this method. Plastic containers and transfer appliances shall not be used in the test. 3.1 Reagents 3.1.1 Dichloromethane (CH2Cl2). 3.1.2 Acetone (C3H6O). 3.2 Standard products 3.2.1 Triethylamine (C6H15N, CAS No.: 121-44-8): with purity ≥99%, or reference material approved and awarded with reference material certificate by the State. 3.2.2 Tributylamine (C12H27N, CAS No.: 121-44-8): with purity ≥99%, or reference material approved and awarded with reference material certificate by the State. 3.3 Preparation of standard solutions 3.3.1 Standard stock solution Accurately weigh 10 mg of triethylamine and 10 mg of tributylamine (accurate to 0.1 mg), put into a beaker (50mL), and add in about 30mL of dichloromethane; transfer into a volumetric flask (100mL) after dissolution, scale the volume with dichloromethane and shake well, and then obtain the standard stock solution. The standard stock solution shall be sealed in dark place at 4℃, with validity period of one month. 3.3.2 Standard working solution Transfer 4.00 mL of standard stock solution, dilute it to 100mL with dichloromethane, scale the volume and shake well; transfer 1.00 mL, 2.00 mL, 3.00 mL, 4.00 mL and 5.00 mL of the diluted solutions into five different volumetric flasks (20mL) respectively, scale the volume with dichloromethane and shake well, and then obtain the standard working solution with the concentration of 0.2 mg/L, 0.4 mg/L, 0.6 mg/L, 0.8 mg/L and 1.0 mg/L respectively. The standard working solution shall be prepared immediately before use. 4 Instruments and Apparatus 4.1 Gas chromatograph: equipped with nitrogen-phosphorous detector. 4.2 Analytical balance or electronic balance: with the sensibility of 0.1 mg. 4.3 Centrifuger: 3,000 r/min. 4.4 Rotary evaporator. 4.5 Graduated centrifuge tube with stopper: 2mL or 5mL. 4.6 Syringe-driven filter for organic phase: 0.22 μm. 5 Analysis Steps 5.1 Preparation of specimen Cut the specimen into those with particle size less than 5 mm×5 mm with the cutting tool firstly, and then weigh them; the sample shall not be heated and softened during cutting. 5.2 Preparation of specimen solution Weigh 1 g of specimen (accurate to 0.001 g), put it into a conical flask (200mL), and add in 20mL of dichloromethane; after the sample is dissolved completely, shake the conical flask and dropwise add in 100mL of acetone with separating funnel simultaneously; shake the solution in the flask well after finishing dropping, centrifuge for 10 min, and take the supernatant to carry out rotary evaporation until its volume is about 1mL; transfer the concentrated solution into the graduated centrifuge tube with stopper completely, scale the volume to 2.0 mL with dichloromethane, and obtain the specimen solution for determination of gas chromatography. Note 1: the solution may be centrifuged in several times, and the centrifuged supernatant is required to be combined. Note 2: if it is slightly turbid in specimen solution, syringe-driven filter for organic phase may be adopted for filtration and then gas chromatograph may be adopted for determination. 5.3 Blank test The analysis steps, reagents and dosage identical with those in 5.2 are adopted, with parallel operation carried out except the specimen is not added. 5.4 Reference conditions of gas chromatography 5.4.1 Chromatographic column: ZB-5 quartz capillary column, with length of 30 m, inner diameter of 0.32 mm and film thickness of 5 μm; or equivalent; 5.4.2 Column temperature: maintain the initial temperature 40℃ for 5 min, then raise to 250℃ at a rate of 20℃/min and maintain for 2.5 min; 5.4.3 Temperature of injection port: 200℃; 5.4.4 Temperature of detector: 250℃; 5.4.5 Carrier gas: nitrogen (with purity≥99.999%); with flow rate of 1.0mL/min; 5.4.6 Hydrogen flow rate of detector: 3 mL/min; 5.4.7 Air flow rate of detector: 60 mL/min; 5.4.8 Injection volume: 1 μL; 5.4.9 Injection mode: splitless injection.
Foreword i 1 Scope 2 Principle 3 Reagents and Materials 4 Instruments and Apparatus 5 Analysis Steps 6 Expression of Analysis Results 7 Accuracy 8 Others Annex A Gas Chromatogram of Triethylamine and Tributylamine
Referred in GB 31604.37-2016:
*GB 31604.36-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Creosote in Cork
*GB 31604.34-2016 National Food Safety Standard - Food Contact Materials and Articles - Determination of Lead and Its Migration
*GB 31604.33-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Migration of Nickel
*GB 31604.32-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Sulfur Dioxide in Wood Materials
*GB 31604.31-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Vinyl Chloride and Determination of Migration
*GB 31604.30-2016 National Food Safety Standard - Food Contact Materials and Articles - Determination of the Content and Migration of Phthalate Esters
*GB 31604.29-2016 National Food Safety Standard - Food Contact Materials and Articles - Determination of Migration of Methyl Methacrylate
*GB 31604.28-2016 National Food Safety Standard - Food Contact Materials and Articles - Determination of Di(2-ethylhexyl)adipate and Determination of Migration
*HG/T 4107-2016 Methanol synthesis catalysts
*GB 31604.26-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Epichlorohydrin and Determination of Migration
GB 31604.37-2016 is referred in:
*GB 51173-2016 Code for design of dewatering and draining in opne pit mine of coal industry
*GB/T 33014.3-2016 Road vehicles-Component test methods for electrical/electronic disturbances from narrowband radiated electromagnetic energy- Part 3:Transverse electromagnetic(TEM)cell
*HG/T 20511-2014 Design code for signal alarm and interlock system engineering
*GB/T 17505-2016 Steel and steel products General technical delivery requirements
*GB 31604.47-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Fluorescent Brightener in Paper, Paperboards and Paper Products
*GB 31604.45-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Isocyanate
*GB 31604.42-2016 National Food Safety Standard - Food Contact Materials and Articles - Determination of Zinc Migration
*GB 31604.41-2016 National Food Safety Standard - Food Contact Materials and Articles- Determination of Stibium Migration
*GB 31604.39-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Polychlorobiphenyls (PCBs) in Food Contact Paper
*GB 31604.38-2016 National Food Safety Standard - Food Contact Materials and Articles - Determination of Arsenic and Migration
Code of China
Standard
GB 31604.37-2016  National Food Safety Standard - Food Contact Materials and Articles -Determination of Triethylamine and Tributylamine (English Version)
Standard No.GB 31604.37-2016
Statusvalid
LanguageEnglish
File FormatPDF
Word Count2000 words
Price(USD)40.0
Implemented on2017-4-19
Deliveryvia email in 1 business day
Detail of GB 31604.37-2016
Standard No.
GB 31604.37-2016
English Name
National Food Safety Standard - Food Contact Materials and Articles -Determination of Triethylamine and Tributylamine
Chinese Name
食品安全国家标准 食品接触材料及制品 三乙胺和三正丁胺的测定
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
National Health and Family Planning Commission
Issued on
2016-10-19
Implemented on
2017-4-19
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
SN/T 2890-2011 Food contact materials for export-Polymers---Determination of triethylamine and tributylamine in polycarbonate resinand its products-Gas chromatography
Language
English
File Format
PDF
Word Count
2000 words
Price(USD)
40.0
Keywords
GB 31604.37-2016, GB/T 31604.37-2016, GBT 31604.37-2016, GB31604.37-2016, GB 31604.37, GB31604.37, GB/T31604.37-2016, GB/T 31604.37, GB/T31604.37, GBT31604.37-2016, GBT 31604.37, GBT31604.37
Introduction of GB 31604.37-2016
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard replaces SN/T 2890-2011 Food Contact Materials for Export - Polymers - Determination of Triethylamine and Tributylamine in Polycarbonate Resin and Its Products - Gas Chromatography. The following main changes have been made with respect to SN/T 2890-2011 (the previous edition): ——This standard is renamed as "National Food Safety Standard - Food Contact Materials and Articles - Determination of Triethylamine and Tributylamine". ——The requirement of "plastic containers and transfer appliances shall not be used in the test" is added; ——"Measuring cylinder with stopper" in former standard is changed into "graduated centrifuge tube with stopper". National Food Safety Standard Food Contact Materials and Articles Determination of Triethylamine and Tributylamine 1 Scope This standard specifies the gas chromatography for the determination of the contents of triethylamine and tributylamine in food contact materials and articles. This standard is applicable to the determination of triethylamine and tributylamine in polycarbonate food contact materials and articles. 2 Principle After dissolving the sample with dichloromethane, add in acetone to precipitate the polymer resin; after concentration and scaling of the volume, carry out determination by gas chromatography and quantative determination by external standard method. 3 Reagents and Materials Unless otherwise specified, analytically-pure reagents are adopted for the purpose of this method. Plastic containers and transfer appliances shall not be used in the test. 3.1 Reagents 3.1.1 Dichloromethane (CH2Cl2). 3.1.2 Acetone (C3H6O). 3.2 Standard products 3.2.1 Triethylamine (C6H15N, CAS No.: 121-44-8): with purity ≥99%, or reference material approved and awarded with reference material certificate by the State. 3.2.2 Tributylamine (C12H27N, CAS No.: 121-44-8): with purity ≥99%, or reference material approved and awarded with reference material certificate by the State. 3.3 Preparation of standard solutions 3.3.1 Standard stock solution Accurately weigh 10 mg of triethylamine and 10 mg of tributylamine (accurate to 0.1 mg), put into a beaker (50mL), and add in about 30mL of dichloromethane; transfer into a volumetric flask (100mL) after dissolution, scale the volume with dichloromethane and shake well, and then obtain the standard stock solution. The standard stock solution shall be sealed in dark place at 4℃, with validity period of one month. 3.3.2 Standard working solution Transfer 4.00 mL of standard stock solution, dilute it to 100mL with dichloromethane, scale the volume and shake well; transfer 1.00 mL, 2.00 mL, 3.00 mL, 4.00 mL and 5.00 mL of the diluted solutions into five different volumetric flasks (20mL) respectively, scale the volume with dichloromethane and shake well, and then obtain the standard working solution with the concentration of 0.2 mg/L, 0.4 mg/L, 0.6 mg/L, 0.8 mg/L and 1.0 mg/L respectively. The standard working solution shall be prepared immediately before use. 4 Instruments and Apparatus 4.1 Gas chromatograph: equipped with nitrogen-phosphorous detector. 4.2 Analytical balance or electronic balance: with the sensibility of 0.1 mg. 4.3 Centrifuger: 3,000 r/min. 4.4 Rotary evaporator. 4.5 Graduated centrifuge tube with stopper: 2mL or 5mL. 4.6 Syringe-driven filter for organic phase: 0.22 μm. 5 Analysis Steps 5.1 Preparation of specimen Cut the specimen into those with particle size less than 5 mm×5 mm with the cutting tool firstly, and then weigh them; the sample shall not be heated and softened during cutting. 5.2 Preparation of specimen solution Weigh 1 g of specimen (accurate to 0.001 g), put it into a conical flask (200mL), and add in 20mL of dichloromethane; after the sample is dissolved completely, shake the conical flask and dropwise add in 100mL of acetone with separating funnel simultaneously; shake the solution in the flask well after finishing dropping, centrifuge for 10 min, and take the supernatant to carry out rotary evaporation until its volume is about 1mL; transfer the concentrated solution into the graduated centrifuge tube with stopper completely, scale the volume to 2.0 mL with dichloromethane, and obtain the specimen solution for determination of gas chromatography. Note 1: the solution may be centrifuged in several times, and the centrifuged supernatant is required to be combined. Note 2: if it is slightly turbid in specimen solution, syringe-driven filter for organic phase may be adopted for filtration and then gas chromatograph may be adopted for determination. 5.3 Blank test The analysis steps, reagents and dosage identical with those in 5.2 are adopted, with parallel operation carried out except the specimen is not added. 5.4 Reference conditions of gas chromatography 5.4.1 Chromatographic column: ZB-5 quartz capillary column, with length of 30 m, inner diameter of 0.32 mm and film thickness of 5 μm; or equivalent; 5.4.2 Column temperature: maintain the initial temperature 40℃ for 5 min, then raise to 250℃ at a rate of 20℃/min and maintain for 2.5 min; 5.4.3 Temperature of injection port: 200℃; 5.4.4 Temperature of detector: 250℃; 5.4.5 Carrier gas: nitrogen (with purity≥99.999%); with flow rate of 1.0mL/min; 5.4.6 Hydrogen flow rate of detector: 3 mL/min; 5.4.7 Air flow rate of detector: 60 mL/min; 5.4.8 Injection volume: 1 μL; 5.4.9 Injection mode: splitless injection.
Contents of GB 31604.37-2016
Foreword i 1 Scope 2 Principle 3 Reagents and Materials 4 Instruments and Apparatus 5 Analysis Steps 6 Expression of Analysis Results 7 Accuracy 8 Others Annex A Gas Chromatogram of Triethylamine and Tributylamine
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 31604.37-2016, GB/T 31604.37-2016, GBT 31604.37-2016, GB31604.37-2016, GB 31604.37, GB31604.37, GB/T31604.37-2016, GB/T 31604.37, GB/T31604.37, GBT31604.37-2016, GBT 31604.37, GBT31604.37