2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 36893-2018
GB 36893-2018   Minimum allowable values of the energy efficiency and energy efficiency grades for air cleaners (English Version)
Standard No.: GB 36893-2018 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5500 words Translation Price(USD):130.0 remind me the price change

Email:

Implemented on:2019-12-1 Delivery: via email in 1 business day

→ → →

,2025-10-1,2019-12-1,C3D106AC15212A531542689571899
Standard No.: GB 36893-2018
English Name: Minimum allowable values of the energy efficiency and energy efficiency grades for air cleaners
Chinese Name: 空气净化器能效限定值及能效等级
Chinese Classification: F01    Technical management
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2018-11-19
Implemented on: 2019-12-1
Status: superseded
Superseded by:GB 36893-2024 Minimum allowable values of energy efficiency and energy efficiency grades for air cleaner
Superseded on:2025-10-1
Target Language: English
File Format: PDF
Word Count: 5500 words
Translation Price(USD): 130.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. This standard was proposed and prepared by the Standardization Administration of the People's Republic of China. Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Air Cleaners 1 Scope This standard specifies minimum allowable values of energy efficiency and energy efficiency grades for air cleaners as well as their test and calculation methods. This standard is applicable to air cleaners with rated voltage not greater than 250 V and certain purifying capacity of particles (clean air delivery rate of particles is 50 m3/h~800 m3/h). This standard is not applicable to: ——air cleaner adopting ion generating technology only; ——airway-type air cleaning unit and other similar air cleaners; ——air cleaner having purifying capacity of gaseous pollutants and microorganisms; ——air cleaner specially designed for industrial use, medical use and vehicles; ——air cleaner used in special environment with corrosive and explosive gas (e.g., dust, vapor and methane gas). 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 18801-2015 Air Cleaner GB/T 18883-2002 Indoor Air Quality Standard 3 Terms and Definitions For the purposes of this document, the following terms and definitions apply. 3.1 rated condition the working state of the air cleaner corresponding to the cleaner's nominal purifying capacity 3.2 clean air delivery rate of particle; CADR the parameter in terms of purifying capacity of particles for air cleaners under rated condition and specified test condition; which shows the provision rate of clean air in terms of particles by air cleaner 3.3 input power of purify the required input power for air cleaner providing clean air delivery rate of particle under rated condition Note 1: Including the input power of electrical components uncapable of being turned off individually such as motor, high-voltage electrostatic generator, ion generator, control and drive circuits. Note 2: Excluding other separable functions of air cleaner; only the consumed input power required for realizing purifying capacity of particles is considered. 3.4 energy efficiency ratio; EER the ratio of CADR to input power of purify provided by the air cleaner under rated condition 3.5 standby power the input power of the air cleaner under state that the cleaner is connected to the power supply to provide instruction waiting (including restart) with information or status display (including clock), communication protocol and other functions simultaneously but without any function for contaminants purification Note: Restart is a kind of function to switch the air cleaner to mode of providing contaminants purification by remote controller, internal sensor or timer and other means. 3.6 purification efficiency of gaseous pollutants the parameter of the air cleaner in terms of purifying capacity for gaseous pollutants under rated condition and specified test conditions and after operation in estimated equivalent testing time, which shows the purification efficiency on gaseous pollutants of air cleaner after 1 h operation under working condition of nominal applicable area 3.7 minimum allowable values of energy efficiency the minimum allowable value of energy efficiency ratio and the maximum value of standby power for the air cleaner under rated condition and specified test conditions 4 Energy Efficiency Grades Energy efficiencies of air cleaner are divided into three grades (see Table 1), among which Grade 1 is the highest. The energy efficiency ratio and standby power of all-grade products shall meet the requirements of Table 1. Table 1 Indexes of Energy Efficiency Grade Energy efficiency grade Energy efficiency ratio, m3/(W·h) Standby power, W Category I Category II 1 EER≥13.00 EER≥11.00 ≤1.0 (only instruction waiting is provided) ≤2.0 (including other functions) 2 10.00≤EER<13.00 8.00≤EER<11.00 3 3.50≤EER<10.00 3.50≤EER<8.00 Note: Category I products refer to the air cleaner which is declared to only have purifying capacity of particles or whose measured purification efficiency of any kind of gaseous pollutant that is declared by the cleaner to have purifying capacity is less than 50%; Category II products refer to the air cleaner which is declared to have purifying capacity of particles and gaseous pollutants or whose measured purification efficiency of each kind of gaseous pollutant that is declared by the cleaner to have purifying capacity is not less than 50%. 5 Minimum Allowable Values of Energy Efficiency The minimum allowable value of energy efficiency for air cleaner is energy efficiency grade 3 in Table 1. 6 Test and Calculation Methods 6.1 Test method 6.1.1 Energy efficiency ratio 6.1.1.1 Clean air delivery rate of particle The test for clean air delivery rate of particle is conducted according to the method specified in Annex B, GB/T 18801-2015 and is expressed in CADR; the result is reserved as integer. 6.1.1.2 Input power of purify The test for input power of purify for air cleaner is conducted according to the method specified in 6.8.1, GB/T 18801-2015 and is expressed in P; the result is accurate to one decimal.
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Energy Efficiency Grades 5 Minimum Allowable Values of Energy Efficiency 6 Test and Calculation Methods Annex A (Normative) Test and Calculation Methods for Purification Efficiency of Gaseous Pollutants
Referred in GB 36893-2018:
*GB/T 18801-2015 Air Cleaner
*GB/T 18883-2002 Indoor air quality standard
*GB 2762-2022 National Food Safety Standard - Maximum Levels of Contaminants in Foods
*GB/T 8897.2-2021 Primary batteries—Part 2: Physical and electrical specifications
*FZ/T 81007-2003 Casual wear
*GB 8898-2011 Audio,video and similar electronic apparatus—Safety requirements
*GB/T 22849-2014 Knitted T-shirt
*FZ/T 81007-2012 Casual wear
*GB/T 8163-2018 Seamless steel pipes for liquid service
*GA 374-2019 Burglary-resistant electronic locks
*GB 50009-2012 Load Code for the Design of Building Structures
*GB/T 26572-2011 Requirements of concentration limits for certain restricted substances in electrical and electronic products
*GB 4806.7-2016 National Food Safety Standard - Food Contact Plastic Materials and Articles
*GB/T 1591-2018 High strength low alloy structural steels
*FZ/T 81006-2017 Jeanswear
*GB 2763-2021 National Food Safety Standard-Maximum Residue Limits for Pesticides in Food
*GB 9706.1-2020 Medical electrical equipment—Part 1: General requirements for basic safety and essential performance
*SJ/T 11364-2014/XG1-2017 Marking for the restriction of the use of hazardous substances in electrical and electronic product,including Amendment 1
*GBT32960-
*GB/T 22849-2014 Knitted T-shirt
Code of China
Standard
GB 36893-2018  Minimum allowable values of the energy efficiency and energy efficiency grades for air cleaners (English Version)
Standard No.GB 36893-2018
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count5500 words
Price(USD)130.0
Implemented on2019-12-1
Deliveryvia email in 1 business day
Detail of GB 36893-2018
Standard No.
GB 36893-2018
English Name
Minimum allowable values of the energy efficiency and energy efficiency grades for air cleaners
Chinese Name
空气净化器能效限定值及能效等级
Chinese Classification
F01
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2018-11-19
Implemented on
2019-12-1
Status
superseded
Superseded by
GB 36893-2024 Minimum allowable values of energy efficiency and energy efficiency grades for air cleaner
Superseded on
2025-10-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
5500 words
Price(USD)
130.0
Keywords
GB 36893-2018, GB/T 36893-2018, GBT 36893-2018, GB36893-2018, GB 36893, GB36893, GB/T36893-2018, GB/T 36893, GB/T36893, GBT36893-2018, GBT 36893, GBT36893
Introduction of GB 36893-2018
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. This standard was proposed and prepared by the Standardization Administration of the People's Republic of China. Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Air Cleaners 1 Scope This standard specifies minimum allowable values of energy efficiency and energy efficiency grades for air cleaners as well as their test and calculation methods. This standard is applicable to air cleaners with rated voltage not greater than 250 V and certain purifying capacity of particles (clean air delivery rate of particles is 50 m3/h~800 m3/h). This standard is not applicable to: ——air cleaner adopting ion generating technology only; ——airway-type air cleaning unit and other similar air cleaners; ——air cleaner having purifying capacity of gaseous pollutants and microorganisms; ——air cleaner specially designed for industrial use, medical use and vehicles; ——air cleaner used in special environment with corrosive and explosive gas (e.g., dust, vapor and methane gas). 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 18801-2015 Air Cleaner GB/T 18883-2002 Indoor Air Quality Standard 3 Terms and Definitions For the purposes of this document, the following terms and definitions apply. 3.1 rated condition the working state of the air cleaner corresponding to the cleaner's nominal purifying capacity 3.2 clean air delivery rate of particle; CADR the parameter in terms of purifying capacity of particles for air cleaners under rated condition and specified test condition; which shows the provision rate of clean air in terms of particles by air cleaner 3.3 input power of purify the required input power for air cleaner providing clean air delivery rate of particle under rated condition Note 1: Including the input power of electrical components uncapable of being turned off individually such as motor, high-voltage electrostatic generator, ion generator, control and drive circuits. Note 2: Excluding other separable functions of air cleaner; only the consumed input power required for realizing purifying capacity of particles is considered. 3.4 energy efficiency ratio; EER the ratio of CADR to input power of purify provided by the air cleaner under rated condition 3.5 standby power the input power of the air cleaner under state that the cleaner is connected to the power supply to provide instruction waiting (including restart) with information or status display (including clock), communication protocol and other functions simultaneously but without any function for contaminants purification Note: Restart is a kind of function to switch the air cleaner to mode of providing contaminants purification by remote controller, internal sensor or timer and other means. 3.6 purification efficiency of gaseous pollutants the parameter of the air cleaner in terms of purifying capacity for gaseous pollutants under rated condition and specified test conditions and after operation in estimated equivalent testing time, which shows the purification efficiency on gaseous pollutants of air cleaner after 1 h operation under working condition of nominal applicable area 3.7 minimum allowable values of energy efficiency the minimum allowable value of energy efficiency ratio and the maximum value of standby power for the air cleaner under rated condition and specified test conditions 4 Energy Efficiency Grades Energy efficiencies of air cleaner are divided into three grades (see Table 1), among which Grade 1 is the highest. The energy efficiency ratio and standby power of all-grade products shall meet the requirements of Table 1. Table 1 Indexes of Energy Efficiency Grade Energy efficiency grade Energy efficiency ratio, m3/(W·h) Standby power, W Category I Category II 1 EER≥13.00 EER≥11.00 ≤1.0 (only instruction waiting is provided) ≤2.0 (including other functions) 2 10.00≤EER<13.00 8.00≤EER<11.00 3 3.50≤EER<10.00 3.50≤EER<8.00 Note: Category I products refer to the air cleaner which is declared to only have purifying capacity of particles or whose measured purification efficiency of any kind of gaseous pollutant that is declared by the cleaner to have purifying capacity is less than 50%; Category II products refer to the air cleaner which is declared to have purifying capacity of particles and gaseous pollutants or whose measured purification efficiency of each kind of gaseous pollutant that is declared by the cleaner to have purifying capacity is not less than 50%. 5 Minimum Allowable Values of Energy Efficiency The minimum allowable value of energy efficiency for air cleaner is energy efficiency grade 3 in Table 1. 6 Test and Calculation Methods 6.1 Test method 6.1.1 Energy efficiency ratio 6.1.1.1 Clean air delivery rate of particle The test for clean air delivery rate of particle is conducted according to the method specified in Annex B, GB/T 18801-2015 and is expressed in CADR; the result is reserved as integer. 6.1.1.2 Input power of purify The test for input power of purify for air cleaner is conducted according to the method specified in 6.8.1, GB/T 18801-2015 and is expressed in P; the result is accurate to one decimal.
Contents of GB 36893-2018
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Energy Efficiency Grades 5 Minimum Allowable Values of Energy Efficiency 6 Test and Calculation Methods Annex A (Normative) Test and Calculation Methods for Purification Efficiency of Gaseous Pollutants
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 36893-2018, GB/T 36893-2018, GBT 36893-2018, GB36893-2018, GB 36893, GB36893, GB/T36893-2018, GB/T 36893, GB/T36893, GBT36893-2018, GBT 36893, GBT36893