GB 3836.11-2008   Explosive atmospheres - Part 11: Equipment protection by flameproof enclosures d - Method of test for ascertainment of maximum experimental safe gap (English Version)
Standard No.: GB 3836.11-2008 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 3000 words Translation Price(USD):224.0 remind me the price change

Email:

Implemented on:2009-10-1 Delivery: via email in 1 business day

→ → →

,2018-7-1,2009-10-1,141138181858465BF7793394CBD2F
Standard No.: GB 3836.11-2008
English Name: Explosive atmospheres - Part 11: Equipment protection by flameproof enclosures d - Method of test for ascertainment of maximum experimental safe gap
Chinese Name: 爆炸性环境 第11部分:由隔爆外壳“d”保护的设备 最大试验安全间隙测定方法
Chinese Classification: K35    Explosion-proof electric apparatus
Professional Classification: GB    National Standard
ICS Classification: 29.260.20 29.260.20    Electrical apparatus for explosive atmospheres 29.260.20
Source Content Issued by: AQSIQ; SAC
Issued on: 1991-05-27
Implemented on: 2009-10-1
Status: superseded
Superseded by:GB/T 3836.11-2017 Explosive atmospheres—Part 11: Material characteristics for gas and vapourclassification—Test methods and data
Superseded on:2018-7-1
Superseding:GB 3836.11-1991 Electrical apparatus for explosive atmospheres-Method of test for ascertainment if maximum experimental safe gap
Target Language: English
File Format: PDF
Word Count: 3000 words
Translation Price(USD): 224.0
Delivery: via email in 1 business day
1 Scope This Part of GB 3836 describes a test method intended for the measurement of the maximum experimental safe gaps for gas- or vapour-air mixtures under normal conditions of temperature 1) and pressure so as to permit the selection of an appropriate group of flameproof enclosures. The method does not take into account the possible effects of obstacles on the safe gaps 2). 2 Terms and Definitions For the purpose of this Part of GB 3836, the following definitions apply. 2.1 Maximum experimental safe gap (MESG) Maximum gap between the two parts of the interior chamber which, under the test conditions specified below, prevents ignition of the external gas mixture through a 25 mm long flame path when the internal mixture is ignited, for all concentrations of the tested gas or vapour in air 3 Outline of Method
GB 3836.11-2008 is referred in:
* GB 3836.1-2010 Explosive atmospheres—Part 1:Equipment—General requirements
* GB 3836.2-2010 Explosive atmospheres—Part 2:Equipment protection by flameproof enclosures“d”
* GB 3836.1-2010 Explosive atmospheres—Part 1:Equipment—General requirements
* GB 3836.2-2010 Explosive atmospheres—Part 2:Equipment protection by flameproof enclosures“d”
* GB 3836.12-2008 Explosive atmospheres - Part 12: Classification of gases or vapours with air according to their maximum experimental safe gaps and minimum igniting current
* GB/T 3215-2007 Centrifugal pumps for petroleum petrochemical and natural gas industries
Code of China
Standard
GB 3836.11-2008  Explosive atmospheres - Part 11: Equipment protection by flameproof enclosures d - Method of test for ascertainment of maximum experimental safe gap (English Version)
Standard No.GB 3836.11-2008
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count3000 words
Price(USD)224.0
Implemented on2009-10-1
Deliveryvia email in 1 business day
Detail of GB 3836.11-2008
Standard No.
GB 3836.11-2008
English Name
Explosive atmospheres - Part 11: Equipment protection by flameproof enclosures d - Method of test for ascertainment of maximum experimental safe gap
Chinese Name
爆炸性环境 第11部分:由隔爆外壳“d”保护的设备 最大试验安全间隙测定方法
Chinese Classification
K35
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
1991-05-27
Implemented on
2009-10-1
Status
superseded
Superseded by
GB/T 3836.11-2017 Explosive atmospheres—Part 11: Material characteristics for gas and vapourclassification—Test methods and data
Superseded on
2018-7-1
Abolished on
Superseding
GB 3836.11-1991 Electrical apparatus for explosive atmospheres-Method of test for ascertainment if maximum experimental safe gap
Language
English
File Format
PDF
Word Count
3000 words
Price(USD)
224.0
Keywords
GB 3836.11-2008, GB/T 3836.11-2008, GBT 3836.11-2008, GB3836.11-2008, GB 3836.11, GB3836.11, GB/T3836.11-2008, GB/T 3836.11, GB/T3836.11, GBT3836.11-2008, GBT 3836.11, GBT3836.11
Introduction of GB 3836.11-2008
1 Scope This Part of GB 3836 describes a test method intended for the measurement of the maximum experimental safe gaps for gas- or vapour-air mixtures under normal conditions of temperature 1) and pressure so as to permit the selection of an appropriate group of flameproof enclosures. The method does not take into account the possible effects of obstacles on the safe gaps 2). 2 Terms and Definitions For the purpose of this Part of GB 3836, the following definitions apply. 2.1 Maximum experimental safe gap (MESG) Maximum gap between the two parts of the interior chamber which, under the test conditions specified below, prevents ignition of the external gas mixture through a 25 mm long flame path when the internal mixture is ignited, for all concentrations of the tested gas or vapour in air 3 Outline of Method
Contents of GB 3836.11-2008
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 3836.11-2008, GB/T 3836.11-2008, GBT 3836.11-2008, GB3836.11-2008, GB 3836.11, GB3836.11, GB/T3836.11-2008, GB/T 3836.11, GB/T3836.11, GBT3836.11-2008, GBT 3836.11, GBT3836.11