GB 3836.18-2010   Explosive atmospheres—Part 18:Intrinsically safe system (English Version)
Standard No.: GB 3836.18-2010 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 12000 words Translation Price(USD):240.0 remind me the price change

Email:

Implemented on:2011-8-1 Delivery: via email in 1 business day

→ → →

,2018-7-1,2011-8-1,141138181891665EF58D77F836396
Standard No.: GB 3836.18-2010
English Name: Explosive atmospheres—Part 18:Intrinsically safe system
Chinese Name: 爆炸性环境 第18部分:本质安全系统
Chinese Classification: K35    Explosion-proof electric apparatus
Professional Classification: GB    National Standard
ICS Classification: 29.260.20 29.260.20    Electrical apparatus for explosive atmospheres 29.260.20
Source Content Issued by: AQSIQ; SAC
Issued on: 2010-08-09
Implemented on: 2011-8-1
Status: superseded
Superseded by:GB/T 3836.18-2017 Explosive atmospheres-Part 18:Intrinsically safe electrical systems
Superseded on:2018-7-1
Target Language: English
File Format: PDF
Word Count: 12000 words
Translation Price(USD): 240.0
Delivery: via email in 1 business day
1 Scope 1.1 This part of GB 3836 contains the specific requirements for construction and assessment of intrinsically safe electrical systems, type of protection “i”, intended for use, as a whole or in part, in explosive atmospheres in Group II locations. This standard is intended for use by the designer of the system who may be a manufacturer, a specialist consultant or a member of the end-user’s staff. NOTE 1 The detailed requirements for construction and assessment of intrinsically safe electrical systems in Group I and Group III locations are intended to be given out in the next revision of this part. 1.2 This part supplements GB 3836.4-2010, the requirements of which apply to electrical apparatus used in intrinsically safe electrical systems. As for the apparatus in Group II system intended for used in the explosive atmospheres, the groups of whose surface temperature shall be given out in accordance with GB 3836.1 and GB 3836.4. NOTE 2 The detailed requirements for “ic” intrinsically safe systems are intended to be given out in the next revision of this part. 1.3 The installation requirements of a Group II system designed in accordance with this part are specified in GB 3836.15-2000. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 3836.1 Explosive atmospheres—Part 1: Equipment—General requirements (GB 3836.1-2010, IEC 60079-0:2007, MOD) GB 3836.4-2010 Explosive atmospheres—Part 4: Equipment protection by intrinsic safety i (IEC 60079-11:2006, MOD) GB 3836.15-2010 Electrical apparatus for explosive gas atmospheres-Part 15: Electrical installations in hazardous areas (other than mines) (eqv IEC 60079-14:1998) GB/T 16927.1 High voltage test techniques--Part 1: General test requirements (GB/T 16927.1-1997, eqv IEC 60060-1:1989) 3 Definitions For the purposes of this document, the following definitions, specific to intrinsically safe electrical systems, apply. They supplement the definitions which are given in GB 3836.1-2010 and GB 3836.4-2010. 3.1 Intrinsically safe electrical system Assembly of interconnected items of electrical apparatus, described in a descriptive system document, in which the circuits or parts of circuits, intended to be used in an explosive atmosphere, are intrinsically safe circuits 3.1.1 Certified intrinsically safe electrical system Electrical system conforming to 3.1 for which a certificate has been issued confirming that the electrical system complies with this standard 3.1.2 Uncertified intrinsically safe electrical system Electrical system conforming to 3.1 for which the knowledge of the electrical parameters of the items of certified intrinsically safe electrical apparatus, certified associated apparatus, simple apparatus and the knowledge of the electrical and physical parameters of the interconnecting wiring permit the unambiguous deduction that intrinsic safety is preserved 3.2 Descriptive system document Document in which the items of electrical apparatus, their electrical parameters and those of the interconnecting wiring are specified 3.3 System designer Person who is responsible for the descriptive system document, has the necessary competence to fulfill the task and who is empowered to enter into the commitments on behalf of his employer 3.4 Maximum cable capacitance (Cc) Maximum capacitance of the interconnecting cable that can be connected into an intrinsically safe circuit without invalidating intrinsic safety 3.5 Maximum cable inductance (Lc) Maximum inductance of the interconnecting cable that can be connected into an intrinsically safe circuit without invalidating intrinsic safety 3.6 Maximum cable inductance to resistance ratio (Lc/Rc) Maximum value of the ratio inductance (Lc) to resistance (Rc) of the interconnecting cable that can be connected into an intrinsically safe circuit without invalidating intrinsic safety 3.7 Linear power supply Power source from which the available output current is determined by a resistor. The output voltage decreases linearly as the output current increases 3.8 Non-linear power supply Power supply where the output voltage and output current have a non-linear relationship EXAMPLE A supply with a constant voltage output up to a constant current limit controlled by semiconductors.
Contents Foreword i 1 Scope 2 Normative References 3 Definitions 4 Descriptive System Document 5 Grouping and Classification 6 System Categories 7 Ambient Temperature Rating 8 Field Wiring 9 Earthing and Bonding of Intrinsically Safe Systems 10 Protection against Lightning and Other Electrical Surges 11 Assessment of an Intrinsically Safe System 12 Marking Annex A (Normative) Assessment of a Simple Intrinsically Safe System Annex B (Normative) Assessment of Circuits with More than one Source of Power Annex C (Informative) Interconnection of Non-Linear and Linear Intrinsically Safe Circuits Annex D (Normative) Verification of Inductive Parameters Annex E (Informative) A Possible Format for Descriptive Systems Drawings and Installation Drawings Annex F (Informative) Surge Protection of an Intrinsically Safe Circuit
Referred in GB 3836.18-2010:
*GB 3836.1-2010 Explosive atmospheres—Part 1:Equipment—General requirements
*GB 3836.4-2010 Explosive atmospheres—Part 4:Equipment protection by intrinsic safety i
*GB3836.15-2010
*GB/T 16927.1-2011 High-voltage test techniques—Part 1:General definitions and test requirements
*GB/T 18102-2020 Laminate flooring
*GB 7258-2017/XG2-2021 Technical specifications for safety of power-driven vehicles operating on roads,includes Amendment 1 and Amendment 2
*GB 26512-2021 The protection of the occupants of the cab of commercial vehicles
*GB 17675-2021 Steering system of motor vehicles—Basic requirements
*GB 40050-2021 Critical network devices security common requirements
*GB 19578-2021 Fuel consumption limits for passenger cars
*CEL 001-2016 Implementation Rules for Energy Efficiency Labelling of Household Refrigerators
*EJ/T 878-2011 Design criteria for independent spent fuel storage installation
*GJB 9100.6-2017 Regulations for spacecrafts decommissioning - Part 6:Low earth orbit spacecraft
*T/CAQI 164-2020 Electric mask
*GJB 1307-1991 General specification for pyrotechnic device of satellites
*GJB 2361-1995 Methods for matching test of satellite and TT&C station
*GJB 2497-1995 Test method for satellite structures
*QJ 2322A-2006 General specification for spacecraft control system
*QJ 2322-1992 General specification for satellite tracking system
*GJB 2703A-2006 General specification for thermal control system for spacecrafts
GB 3836.18-2010 is referred in:
* GB 3836.1-2010 Explosive atmospheres—Part 1:Equipment—General requirements
* GB 3836.4-2010 Explosive atmospheres—Part 4:Equipment protection by intrinsic safety i
* GB 3836.4-2010 Explosive atmospheres—Part 4:Equipment protection by intrinsic safety i
* GB 3836.1-2010 Explosive atmospheres—Part 1:Equipment—General requirements
* GB 3836.19-2010 Explosive atmospheres—Part 19:Fieldbus intrinsically safe concept(FISCO)Explosive atmospheres—Part 19:Fieldbus intrinsically safe concept(FISCO)
* GB 50257-2014
* GB 31094-2014 Safety Rules for the Construction and Installation of Lifts for Explosive Atmospheres
Code of China
Standard
GB 3836.18-2010  Explosive atmospheres—Part 18:Intrinsically safe system (English Version)
Standard No.GB 3836.18-2010
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count12000 words
Price(USD)240.0
Implemented on2011-8-1
Deliveryvia email in 1 business day
Detail of GB 3836.18-2010
Standard No.
GB 3836.18-2010
English Name
Explosive atmospheres—Part 18:Intrinsically safe system
Chinese Name
爆炸性环境 第18部分:本质安全系统
Chinese Classification
K35
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2010-08-09
Implemented on
2011-8-1
Status
superseded
Superseded by
GB/T 3836.18-2017 Explosive atmospheres-Part 18:Intrinsically safe electrical systems
Superseded on
2018-7-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
12000 words
Price(USD)
240.0
Keywords
GB 3836.18-2010, GB/T 3836.18-2010, GBT 3836.18-2010, GB3836.18-2010, GB 3836.18, GB3836.18, GB/T3836.18-2010, GB/T 3836.18, GB/T3836.18, GBT3836.18-2010, GBT 3836.18, GBT3836.18
Introduction of GB 3836.18-2010
1 Scope 1.1 This part of GB 3836 contains the specific requirements for construction and assessment of intrinsically safe electrical systems, type of protection “i”, intended for use, as a whole or in part, in explosive atmospheres in Group II locations. This standard is intended for use by the designer of the system who may be a manufacturer, a specialist consultant or a member of the end-user’s staff. NOTE 1 The detailed requirements for construction and assessment of intrinsically safe electrical systems in Group I and Group III locations are intended to be given out in the next revision of this part. 1.2 This part supplements GB 3836.4-2010, the requirements of which apply to electrical apparatus used in intrinsically safe electrical systems. As for the apparatus in Group II system intended for used in the explosive atmospheres, the groups of whose surface temperature shall be given out in accordance with GB 3836.1 and GB 3836.4. NOTE 2 The detailed requirements for “ic” intrinsically safe systems are intended to be given out in the next revision of this part. 1.3 The installation requirements of a Group II system designed in accordance with this part are specified in GB 3836.15-2000. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 3836.1 Explosive atmospheres—Part 1: Equipment—General requirements (GB 3836.1-2010, IEC 60079-0:2007, MOD) GB 3836.4-2010 Explosive atmospheres—Part 4: Equipment protection by intrinsic safety i (IEC 60079-11:2006, MOD) GB 3836.15-2010 Electrical apparatus for explosive gas atmospheres-Part 15: Electrical installations in hazardous areas (other than mines) (eqv IEC 60079-14:1998) GB/T 16927.1 High voltage test techniques--Part 1: General test requirements (GB/T 16927.1-1997, eqv IEC 60060-1:1989) 3 Definitions For the purposes of this document, the following definitions, specific to intrinsically safe electrical systems, apply. They supplement the definitions which are given in GB 3836.1-2010 and GB 3836.4-2010. 3.1 Intrinsically safe electrical system Assembly of interconnected items of electrical apparatus, described in a descriptive system document, in which the circuits or parts of circuits, intended to be used in an explosive atmosphere, are intrinsically safe circuits 3.1.1 Certified intrinsically safe electrical system Electrical system conforming to 3.1 for which a certificate has been issued confirming that the electrical system complies with this standard 3.1.2 Uncertified intrinsically safe electrical system Electrical system conforming to 3.1 for which the knowledge of the electrical parameters of the items of certified intrinsically safe electrical apparatus, certified associated apparatus, simple apparatus and the knowledge of the electrical and physical parameters of the interconnecting wiring permit the unambiguous deduction that intrinsic safety is preserved 3.2 Descriptive system document Document in which the items of electrical apparatus, their electrical parameters and those of the interconnecting wiring are specified 3.3 System designer Person who is responsible for the descriptive system document, has the necessary competence to fulfill the task and who is empowered to enter into the commitments on behalf of his employer 3.4 Maximum cable capacitance (Cc) Maximum capacitance of the interconnecting cable that can be connected into an intrinsically safe circuit without invalidating intrinsic safety 3.5 Maximum cable inductance (Lc) Maximum inductance of the interconnecting cable that can be connected into an intrinsically safe circuit without invalidating intrinsic safety 3.6 Maximum cable inductance to resistance ratio (Lc/Rc) Maximum value of the ratio inductance (Lc) to resistance (Rc) of the interconnecting cable that can be connected into an intrinsically safe circuit without invalidating intrinsic safety 3.7 Linear power supply Power source from which the available output current is determined by a resistor. The output voltage decreases linearly as the output current increases 3.8 Non-linear power supply Power supply where the output voltage and output current have a non-linear relationship EXAMPLE A supply with a constant voltage output up to a constant current limit controlled by semiconductors.
Contents of GB 3836.18-2010
Contents Foreword i 1 Scope 2 Normative References 3 Definitions 4 Descriptive System Document 5 Grouping and Classification 6 System Categories 7 Ambient Temperature Rating 8 Field Wiring 9 Earthing and Bonding of Intrinsically Safe Systems 10 Protection against Lightning and Other Electrical Surges 11 Assessment of an Intrinsically Safe System 12 Marking Annex A (Normative) Assessment of a Simple Intrinsically Safe System Annex B (Normative) Assessment of Circuits with More than one Source of Power Annex C (Informative) Interconnection of Non-Linear and Linear Intrinsically Safe Circuits Annex D (Normative) Verification of Inductive Parameters Annex E (Informative) A Possible Format for Descriptive Systems Drawings and Installation Drawings Annex F (Informative) Surge Protection of an Intrinsically Safe Circuit