2025-12-17 216.73.216.99
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 5009.42-2025
GB 5009.42-2025   National food safety standard - Determination of salt index (English Version)
Standard No.: GB 5009.42-2025 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 21000 words Translation Price(USD):630.0 remind me the price change

Email:

Implemented on:2025-9-16 Delivery: via email in 1~5 business day

→ → →

,,2025-9-16,E58DEF50B2AC83C41743066704045
Standard No.: GB 5009.42-2025
English Name: National food safety standard - Determination of salt index
Chinese Name: 食品安全国家标准 食用盐指标的测定
Professional Classification: GB    National Standard
Source Content Issued by: National Health Commission of the People's Republic of China, State Administration for Market Regulation
Issued on: 2025-03-16
Implemented on: 2025-9-16
Status: valid
Superseding:GB 5009.42-2016 National Food Safety Standard--Determination of Table Salt Index
Target Language: English
File Format: PDF
Word Count: 21000 words
Translation Price(USD): 630.0
Delivery: via email in 1~5 business day
GB 5009.42-2025 National food safety standard - Determination of edible salt parameters 1 Scope This standard specifies the method for the determination of edible salt parameters. This standard is applicable to the determination of edible salt parameters. 2 Sodium chloride 2.1 Moisture 2.1.1 Scope The loss-on-drying method is applicable to the determination of moisture in refined salt, low sodium salt, and crushed and washed salt, while the ignition loss method is applicable to the determination of moisture in solar salt. 2.1.2 Loss-on-drying method 2.1.2.1 Principle The specimen is dried at 140±2°C until constant weight is achieved, and its mass is weighted before and after drying. The moisture in edible salt is the sum of the loss on drying and the residual crystalline water in calcium sulfate, magnesium sulfate, calcium chloride, and magnesium chloride after drying. 2.1.2.2 Instruments and apparatus 2.1.2.2.1 Electronic balance: With a sensitivity of 0.0001 g. 2.1.2.2.2 Thermostatic drying oven. 2.1.2.2.3 Flat weighing bottle: 60 mm × 30 mm, dried to constant weight in a thermostatic drying oven at 140±2°C before use. 2.1.2.2.4 Desiccator: Containing effective desiccant. 2.1.2.3 Analytical steps Weigh 10 g (to the nearest 0.0001 g) of a homogeneous specimen crushed to a size smaller than 2 mm in diameter and put it into a pre-weighed flat weighing bottle. Place the bottle in the thermostatic drying oven with the lid tilted against the bottle edge. Heat to 140±2°C and continue drying for 2 h. Cover the bottle, remove it from the oven, transfer it to a desiccator, cool to room temperature, and weigh. Subsequently, dry for 1 h each time and weigh (to the nearest 0.0001 g) until the difference between two consecutive weighing operations does not exceed 5 mg, indicating the realization of constant weight. 2.1.2.4 Expression of analysis results The moisture content in the specimen shall be calculated using Equation (1): (1) Where, X1——the moisture content in the specimen, g/100 g; m1——the total mass of the specimen and the weighing bottle before drying, g; m2——the total mass of the specimen and the weighing bottle after drying, g; m——the mass of the specimen weighed, g; 100——the unit conversion factor; ω1——the calcium sulfate content in the specimen, g/100 g; 0.0662——the conversion factor for residual crystalline water in calcium sulfate in edible salt after drying at 140°C; ω2——the magnesium sulfate content in the specimen, g/100 g; 0.1497——the conversion factor for residual crystalline water in magnesium sulfate in edible salt after drying at 140°C; ω3——the calcium chloride content in the specimen, g/100 g; 0.3246——the conversion factor for residual crystalline water in calcium chloride in edible salt after drying at 140°C; ω4——the magnesium chloride content in the specimen, g/100 g; 0.3784——the conversion factor for residual crystalline water in magnesium chloride in edible salt after drying at 140°C. For moisture content ≥ 1.00 g/100 g, retain three significant figures; for moisture content < 1.00 g/100 g, retain two significant figures. 2.1.2.5 Precision For moisture content < 1.00 g/100 g, the absolute difference between two independent determination results obtained under repeatability conditions shall not exceed 0.10 g/100 g; for moisture content between 1.00 g/100 g and 4.00 g/100 g, the absolute difference shall not exceed 0.20 g/100 g. 2.1.3 Ignition loss method 2.1.3.1 Principle The specimen is ignited at 600°C, and its mass is weighted before and after ignition. The moisture content in edible salt is obtained by subtracting the mass loss of magnesium chloride from the ignition loss. 2.1.3.2 Instruments and apparatus 2.1.3.2.1 Electronic balance: With a sensitivity of 0.0001 g. 2.1.3.2.2 High-temperature furnace. 2.1.3.2.3 Porcelain crucible: 60 mm × 60 mm (with an inner lid), ignited at 600°C in a high-temperature furnace for 1 h before use, then naturally cooled to below 200°C and removed. Place the porcelain crucible on a clean porcelain plate to cool for 5–6 min, transfer it into a desiccator, leave it cool to room temperature, and weigh. 2.1.3.2.4 Desiccator: Containing effective desiccant. 2.1.3.3 Analytical steps Weigh 3 g (to the nearest 0.0001 g) of a homogeneous specimen crushed to a size smaller than 2 mm in diameter and put it into a pre-weighed porcelain crucible. Cover it with the inner and outer lids, and place the porcelain crucible in the high-temperature furnace, then heat to 600°C, and continue ignition for 1 h. After that, stop ignition, allow it to cool naturally to below 200°C, and remove. Place the porcelain crucible on a clean porcelain plate to cool for 5–6 min, transfer it into a desiccator, leave it cool to room temperature, and weigh (to the nearest 0.0001 g).
Contents Foreword III 1 Scope 2 Sodium chloride 3 Potassium chloride 4 Iodine 5 Barium 6 Potassium ferrocyanide 7 Lead 8 Total arsenic 9 Cadmium 10 Total mercury 11 Determination of multiple elements in edible Salt
Code of China
Standard
GB 5009.42-2025  National food safety standard - Determination of salt index (English Version)
Standard No.GB 5009.42-2025
Statusvalid
LanguageEnglish
File FormatPDF
Word Count21000 words
Price(USD)630.0
Implemented on2025-9-16
Deliveryvia email in 1~5 business day
Detail of GB 5009.42-2025
Standard No.
GB 5009.42-2025
English Name
National food safety standard - Determination of salt index
Chinese Name
食品安全国家标准 食用盐指标的测定
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
National Health Commission of the People's Republic of China, State Administration for Market Regulation
Issued on
2025-03-16
Implemented on
2025-9-16
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 5009.42-2016 National Food Safety Standard--Determination of Table Salt Index
Language
English
File Format
PDF
Word Count
21000 words
Price(USD)
630.0
Keywords
GB 5009.42-2025, GB/T 5009.42-2025, GBT 5009.42-2025, GB5009.42-2025, GB 5009.42, GB5009.42, GB/T5009.42-2025, GB/T 5009.42, GB/T5009.42, GBT5009.42-2025, GBT 5009.42, GBT5009.42
Introduction of GB 5009.42-2025
GB 5009.42-2025 National food safety standard - Determination of edible salt parameters 1 Scope This standard specifies the method for the determination of edible salt parameters. This standard is applicable to the determination of edible salt parameters. 2 Sodium chloride 2.1 Moisture 2.1.1 Scope The loss-on-drying method is applicable to the determination of moisture in refined salt, low sodium salt, and crushed and washed salt, while the ignition loss method is applicable to the determination of moisture in solar salt. 2.1.2 Loss-on-drying method 2.1.2.1 Principle The specimen is dried at 140±2°C until constant weight is achieved, and its mass is weighted before and after drying. The moisture in edible salt is the sum of the loss on drying and the residual crystalline water in calcium sulfate, magnesium sulfate, calcium chloride, and magnesium chloride after drying. 2.1.2.2 Instruments and apparatus 2.1.2.2.1 Electronic balance: With a sensitivity of 0.0001 g. 2.1.2.2.2 Thermostatic drying oven. 2.1.2.2.3 Flat weighing bottle: 60 mm × 30 mm, dried to constant weight in a thermostatic drying oven at 140±2°C before use. 2.1.2.2.4 Desiccator: Containing effective desiccant. 2.1.2.3 Analytical steps Weigh 10 g (to the nearest 0.0001 g) of a homogeneous specimen crushed to a size smaller than 2 mm in diameter and put it into a pre-weighed flat weighing bottle. Place the bottle in the thermostatic drying oven with the lid tilted against the bottle edge. Heat to 140±2°C and continue drying for 2 h. Cover the bottle, remove it from the oven, transfer it to a desiccator, cool to room temperature, and weigh. Subsequently, dry for 1 h each time and weigh (to the nearest 0.0001 g) until the difference between two consecutive weighing operations does not exceed 5 mg, indicating the realization of constant weight. 2.1.2.4 Expression of analysis results The moisture content in the specimen shall be calculated using Equation (1): (1) Where, X1——the moisture content in the specimen, g/100 g; m1——the total mass of the specimen and the weighing bottle before drying, g; m2——the total mass of the specimen and the weighing bottle after drying, g; m——the mass of the specimen weighed, g; 100——the unit conversion factor; ω1——the calcium sulfate content in the specimen, g/100 g; 0.0662——the conversion factor for residual crystalline water in calcium sulfate in edible salt after drying at 140°C; ω2——the magnesium sulfate content in the specimen, g/100 g; 0.1497——the conversion factor for residual crystalline water in magnesium sulfate in edible salt after drying at 140°C; ω3——the calcium chloride content in the specimen, g/100 g; 0.3246——the conversion factor for residual crystalline water in calcium chloride in edible salt after drying at 140°C; ω4——the magnesium chloride content in the specimen, g/100 g; 0.3784——the conversion factor for residual crystalline water in magnesium chloride in edible salt after drying at 140°C. For moisture content ≥ 1.00 g/100 g, retain three significant figures; for moisture content < 1.00 g/100 g, retain two significant figures. 2.1.2.5 Precision For moisture content < 1.00 g/100 g, the absolute difference between two independent determination results obtained under repeatability conditions shall not exceed 0.10 g/100 g; for moisture content between 1.00 g/100 g and 4.00 g/100 g, the absolute difference shall not exceed 0.20 g/100 g. 2.1.3 Ignition loss method 2.1.3.1 Principle The specimen is ignited at 600°C, and its mass is weighted before and after ignition. The moisture content in edible salt is obtained by subtracting the mass loss of magnesium chloride from the ignition loss. 2.1.3.2 Instruments and apparatus 2.1.3.2.1 Electronic balance: With a sensitivity of 0.0001 g. 2.1.3.2.2 High-temperature furnace. 2.1.3.2.3 Porcelain crucible: 60 mm × 60 mm (with an inner lid), ignited at 600°C in a high-temperature furnace for 1 h before use, then naturally cooled to below 200°C and removed. Place the porcelain crucible on a clean porcelain plate to cool for 5–6 min, transfer it into a desiccator, leave it cool to room temperature, and weigh. 2.1.3.2.4 Desiccator: Containing effective desiccant. 2.1.3.3 Analytical steps Weigh 3 g (to the nearest 0.0001 g) of a homogeneous specimen crushed to a size smaller than 2 mm in diameter and put it into a pre-weighed porcelain crucible. Cover it with the inner and outer lids, and place the porcelain crucible in the high-temperature furnace, then heat to 600°C, and continue ignition for 1 h. After that, stop ignition, allow it to cool naturally to below 200°C, and remove. Place the porcelain crucible on a clean porcelain plate to cool for 5–6 min, transfer it into a desiccator, leave it cool to room temperature, and weigh (to the nearest 0.0001 g).
Contents of GB 5009.42-2025
Contents Foreword III 1 Scope 2 Sodium chloride 3 Potassium chloride 4 Iodine 5 Barium 6 Potassium ferrocyanide 7 Lead 8 Total arsenic 9 Cadmium 10 Total mercury 11 Determination of multiple elements in edible Salt
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 5009.42-2025, GB/T 5009.42-2025, GBT 5009.42-2025, GB5009.42-2025, GB 5009.42, GB5009.42, GB/T5009.42-2025, GB/T 5009.42, GB/T5009.42, GBT5009.42-2025, GBT 5009.42, GBT5009.42