Position: Chinese Standard in English/GB 50333-2013
GB 50333-2013   Architectural technical code for hospital clean operating department (English Version)
Standard No.: GB 50333-2013 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 28000 words Translation Price(USD):840.0 remind me the price change

Email:

Implemented on:2014-6-1 Delivery: via email in 1 business day

→ → →

,,2014-6-1,14113818301874B14564CC0A89CFB
Standard No.: GB 50333-2013
English Name: Architectural technical code for hospital clean operating department
Chinese Name: 医院洁净手术部建筑技术规范
Professional Classification: GB    National Standard
Source Content Issued by: MOHURD
Issued on: 2013-11-29
Implemented on: 2014-6-1
Status: valid
Superseding:GB 50333-2002 Architectural technical code for hospital clean operating department
Target Language: English
File Format: PDF
Word Count: 28000 words
Translation Price(USD): 840.0
Delivery: via email in 1 business day
1 General provisions 1.0.1 This code is formulated with view to standardizing the design, construction and acceptance of the hospital clean operating department, improving the medical environment control capability of the hospital clean operating department, conforming to the requirements of safety, health, economical efficiency, applicability, energy conservation, environmental protection, etc., and meeting the needs of medical service functions. 1.0.2 This code is applicable to the design, construction and acceptance of the constructed, renovated and extended hospital clean operating departments. 1.0.3 For the construction of the hospital clean operating department, the technical measures for air cleaning shall be focused on and the protection of the operating zone shall be strengthened to reduce the risk of infection. The principle of being practical and economical shall be adhered to in terms of the building facilities. 1.0.4 The clean operating department should be such designed that development space is reserved, and the flexibility and versatility of the design shall be emphasized to adapt to the needs of future renovation or extension. 1.0.5 In addition to this code, the construction of the hospital clean operating department shall also comply with those stipulated in the current relevant standards and codes of the nation.   2 Terms 2.0.1 clean operating department an independent functional zone consisting of part or all of clean operating room, clean supporting space, and non-clean supporting space 2.0.2 clean operating room a kind of operating room where the total amount of the microbial particles and the particles in the operating environment air is reduced to an allowable level by using air cleaning technology 2.0.3 clean supporting space non-operating room having requirement for air cleanliness 2.0.4 non-clean supporting space non-operating room not having requirement for air cleanliness 2.0.5 operating zone a zone that requires special protection, including the operating table and a certain distance outward its four sides 2.0.6 surrounding zone other zone other than the operating zone in the clean operating room 2.0.7 cleanliness class 5 a kind of air cleanliness meeting that the concentration of the particles larger than or equal to 0.5μm is greater than 350 particles/m3 (0.35 particles/L) but less than or equal to 3,500 particles/m3 (3.5 particles/L) and that of the particles larger than or equal to 5μm is 0 particle/L in the ambient air, which is equivalent to the original Class 100 2.0.8 cleanliness class 6 a kind of air cleanliness meeting that the concentration of the particles larger than or equal to 0.5μm is greater than 3,500 particles/m3 (3.5 particles/L) but less than or equal to 35,200 particles/m3 (35.2 particles/L) and that of the particles larger than or equal to 5μm is less than or equal to 293 particles/m3 (0.3 particles/L) in the ambient air, which is equivalent to the original Class 1,000 2.0.9 cleanliness class 7 a kind of air cleanliness meeting that the concentration of the particles larger than or equal to 0.5μm is greater than 35,200 particles/m3 (35.2 particles/L) but less than or equal to 352,000 particles/m3 (352 particles/L) and that of the particles larger than or equal to 5μm is greater than 293 particles/m3 (0.3 particles/L) but less than or equal to 2,930 particles/m3 (3 particles/L) in the ambient air, which is equivalent to the original Class 10,000 2.0.10 cleanliness class 8 a kind of air cleanliness meeting that the concentration of the particles larger than or equal to 0.5μm is greater than 352,000 particles/m3 (352 particles/L) but less than or equal to 3,520,000 particles/m3 (3,520 particles/L) and that of the particles larger than or equal to 5μm is greater than 2,930 particles/m3 (3 particles/L) but less than or equal to 29,300 particles/m3 (29 particles/L) in the ambient air, which is equivalent to the original Class 100,000 2.0.11 cleanliness class 8.5 a kind of air cleanliness meeting that the concentration of the particles larger than or equal to 0.5μm is greater than 3,520,000 particles/m3 (3,520 particles/L) but less than or equal to 11,120,000 particles/m3 (11,120 particles/L) and that of the particles larger than or equal to 5μm is greater than 29,300 particles/m3 (29 particles/L) but less than or equal to 92,500 particles/m3 (93 particles/L) in the ambient air, which is equivalent to the original Class 300,000 2.0.12 as-built the status that the indoor cleaning and air conditioning facilities and functions are complete and not operating, but no medical equipment or staff are allocated indoors
1 General provisions 2 Terms 3 Classification of rooms for clean operating department 4 Technical indexes of rooms for clean operating department 5 Medical process requirements for clean operating department 5.1 Scale of clean operating department 5.2 Hygiene requirements of clean operating department 5.3 Medical process of clean operating department 5.4 Function plane of clean operating department 6 Basic equipment in clean operating room 7 Architecture 7.1 Building environment 7.2 Layout of clean operating department 7.3 Architectural decoration 8 Air conditioning and air cleaning 8.1 Air cleaning and conditioning system 8.2 Air distribution 8.3 Components and materials in the air cleaning and conditioning system 9 Medical gases 9.1 Gas source 9.2 Gas terminal 9.3 Gas piping 9.4 Medical gas acceptance 10 Water supply and drainage 10.1 General requirements 10.2 Water supply 10.3 Water drainage 11 Electrical system 11.1 Power supply 11.2 Power distribution 11.3 Lightning and others 12 Fire prevention 13 Construction acceptance 13.1 Construction 13.2 Project acceptance 13.3 Project inspection Annex A Annual average concentration of inhalable particulate matters/total suspended particulate matters in the cities above prefecture level Annex B Acceptance inspection items of clean operating department project Explanation of wording in this code List of quoted standards
GB 50333-2013 is referred in:
* GB 51039-2014 Code for design of general hospital
*GB 15982-2012 Hygienic standard for disinfection in hospitals
Code of China
Standard
GB 50333-2013   Architectural technical code for hospital clean operating department (English Version)
Standard No.GB 50333-2013
Statusvalid
LanguageEnglish
File FormatPDF
Word Count28000 words
Price(USD)840.0
Implemented on2014-6-1
Deliveryvia email in 1 business day
Detail of GB 50333-2013
Standard No.
GB 50333-2013
English Name
Architectural technical code for hospital clean operating department
Chinese Name
医院洁净手术部建筑技术规范
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
MOHURD
Issued on
2013-11-29
Implemented on
2014-6-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 50333-2002 Architectural technical code for hospital clean operating department
Language
English
File Format
PDF
Word Count
28000 words
Price(USD)
840.0
Keywords
GB 50333-2013, GB/T 50333-2013, GBT 50333-2013, GB50333-2013, GB 50333, GB50333, GB/T50333-2013, GB/T 50333, GB/T50333, GBT50333-2013, GBT 50333, GBT50333
Introduction of GB 50333-2013
1 General provisions 1.0.1 This code is formulated with view to standardizing the design, construction and acceptance of the hospital clean operating department, improving the medical environment control capability of the hospital clean operating department, conforming to the requirements of safety, health, economical efficiency, applicability, energy conservation, environmental protection, etc., and meeting the needs of medical service functions. 1.0.2 This code is applicable to the design, construction and acceptance of the constructed, renovated and extended hospital clean operating departments. 1.0.3 For the construction of the hospital clean operating department, the technical measures for air cleaning shall be focused on and the protection of the operating zone shall be strengthened to reduce the risk of infection. The principle of being practical and economical shall be adhered to in terms of the building facilities. 1.0.4 The clean operating department should be such designed that development space is reserved, and the flexibility and versatility of the design shall be emphasized to adapt to the needs of future renovation or extension. 1.0.5 In addition to this code, the construction of the hospital clean operating department shall also comply with those stipulated in the current relevant standards and codes of the nation.   2 Terms 2.0.1 clean operating department an independent functional zone consisting of part or all of clean operating room, clean supporting space, and non-clean supporting space 2.0.2 clean operating room a kind of operating room where the total amount of the microbial particles and the particles in the operating environment air is reduced to an allowable level by using air cleaning technology 2.0.3 clean supporting space non-operating room having requirement for air cleanliness 2.0.4 non-clean supporting space non-operating room not having requirement for air cleanliness 2.0.5 operating zone a zone that requires special protection, including the operating table and a certain distance outward its four sides 2.0.6 surrounding zone other zone other than the operating zone in the clean operating room 2.0.7 cleanliness class 5 a kind of air cleanliness meeting that the concentration of the particles larger than or equal to 0.5μm is greater than 350 particles/m3 (0.35 particles/L) but less than or equal to 3,500 particles/m3 (3.5 particles/L) and that of the particles larger than or equal to 5μm is 0 particle/L in the ambient air, which is equivalent to the original Class 100 2.0.8 cleanliness class 6 a kind of air cleanliness meeting that the concentration of the particles larger than or equal to 0.5μm is greater than 3,500 particles/m3 (3.5 particles/L) but less than or equal to 35,200 particles/m3 (35.2 particles/L) and that of the particles larger than or equal to 5μm is less than or equal to 293 particles/m3 (0.3 particles/L) in the ambient air, which is equivalent to the original Class 1,000 2.0.9 cleanliness class 7 a kind of air cleanliness meeting that the concentration of the particles larger than or equal to 0.5μm is greater than 35,200 particles/m3 (35.2 particles/L) but less than or equal to 352,000 particles/m3 (352 particles/L) and that of the particles larger than or equal to 5μm is greater than 293 particles/m3 (0.3 particles/L) but less than or equal to 2,930 particles/m3 (3 particles/L) in the ambient air, which is equivalent to the original Class 10,000 2.0.10 cleanliness class 8 a kind of air cleanliness meeting that the concentration of the particles larger than or equal to 0.5μm is greater than 352,000 particles/m3 (352 particles/L) but less than or equal to 3,520,000 particles/m3 (3,520 particles/L) and that of the particles larger than or equal to 5μm is greater than 2,930 particles/m3 (3 particles/L) but less than or equal to 29,300 particles/m3 (29 particles/L) in the ambient air, which is equivalent to the original Class 100,000 2.0.11 cleanliness class 8.5 a kind of air cleanliness meeting that the concentration of the particles larger than or equal to 0.5μm is greater than 3,520,000 particles/m3 (3,520 particles/L) but less than or equal to 11,120,000 particles/m3 (11,120 particles/L) and that of the particles larger than or equal to 5μm is greater than 29,300 particles/m3 (29 particles/L) but less than or equal to 92,500 particles/m3 (93 particles/L) in the ambient air, which is equivalent to the original Class 300,000 2.0.12 as-built the status that the indoor cleaning and air conditioning facilities and functions are complete and not operating, but no medical equipment or staff are allocated indoors
Contents of GB 50333-2013
1 General provisions 2 Terms 3 Classification of rooms for clean operating department 4 Technical indexes of rooms for clean operating department 5 Medical process requirements for clean operating department 5.1 Scale of clean operating department 5.2 Hygiene requirements of clean operating department 5.3 Medical process of clean operating department 5.4 Function plane of clean operating department 6 Basic equipment in clean operating room 7 Architecture 7.1 Building environment 7.2 Layout of clean operating department 7.3 Architectural decoration 8 Air conditioning and air cleaning 8.1 Air cleaning and conditioning system 8.2 Air distribution 8.3 Components and materials in the air cleaning and conditioning system 9 Medical gases 9.1 Gas source 9.2 Gas terminal 9.3 Gas piping 9.4 Medical gas acceptance 10 Water supply and drainage 10.1 General requirements 10.2 Water supply 10.3 Water drainage 11 Electrical system 11.1 Power supply 11.2 Power distribution 11.3 Lightning and others 12 Fire prevention 13 Construction acceptance 13.1 Construction 13.2 Project acceptance 13.3 Project inspection Annex A Annual average concentration of inhalable particulate matters/total suspended particulate matters in the cities above prefecture level Annex B Acceptance inspection items of clean operating department project Explanation of wording in this code List of quoted standards
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 50333-2013, GB/T 50333-2013, GBT 50333-2013, GB50333-2013, GB 50333, GB50333, GB/T50333-2013, GB/T 50333, GB/T50333, GBT50333-2013, GBT 50333, GBT50333