2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 50336-2002
GB 50336-2002   Code of design for building reclaimed water system (English Version)
Standard No.: GB 50336-2002 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 7000 words Translation Price(USD):170.0 remind me the price change

Email:

Implemented on:2003-3-1 Delivery: via email in 1 business day

→ → →

,2018-12-1,2003-3-1,141138181784144D138E5B84B68BE
Standard No.: GB 50336-2002
English Name: Code of design for building reclaimed water system
Chinese Name: 建筑中水设计规范
Chinese Classification: P40    Water supply and draining engineering in general
Professional Classification: GB    National Standard
ICS Classification: 91.140.60 91.140.60    Water supply systems 91.140.60
Source Content Issued by: NDRC
Issued on: 2003-1-10
Implemented on: 2003-3-1
Status: superseded
Superseded by:GB 50336-2018 Standard for design of building reclaimed water system
Superseded on:2018-12-1
Superseding:CECS 30-1991
Target Language: English
File Format: PDF
Word Count: 7000 words
Translation Price(USD): 170.0
Delivery: via email in 1 business day
1 General Provisions 1.0.1 This code is formulated to realize sewage, wastewater recycling, water saving, pollution governing and environment protection and to make the design for building reclaimed water engineering safe, reliable, economic, applicable and advanced in technology. 1.0.2 This code is applicable to the constructed, renovated and extended reclaimed water engineering design of the various civil building and residential are. The reclaimed water engineering design of the domestic sewage and wastewater reutilization in industrial building may be executed with reference to this code. 1.0.3 Various sewage, wastewater resources shall be taken full advantage of according to the local water resource situation and economic development level. 1.0.4 Where various structures and residential areas are constructed in the city and other regions in water shortage, the overall planning design shall include the comprehensive utilization and reclaimed water facility construction of sewage, wastewater and rainwater resources. 1.0.5 The reclaimed water facility engineering projects are applicable to the cities and other regions in water shortage. The reclaimed water facilities shall be constructed according to the local regulations. Reclaimed water facilities must be designed together with the main works. They must be constructed and applied at the same time. 1.0.6 As for the reclaimed water engineering design, water balance and technical and economic analysis shall be executed according to the water quality , water quantity and reclaimed water purposes of the available raw water, to determine the reclaimed water source, systematic type, treatment process and scale reasonably. 1.0.7 The reclaimed water engineering design shall be in the charge of the design organization of the main works. The design schedule of the reclaimed engineering shall be in compliance with the design schedule of the main works, and the design depth at different stages shall meet the requirements of the preparation depth relevant architectonic engineering design documents. 1.0.8 The reclaimed water engineering design quality shall meet the requirements of the quality characteristic and quality evaluation enforcement regulations of the national design document on civil building engineering. 1.0.9 The acceptable age limit of the reclaimed water facilities shall be in conformity of the main building design criteria. 1.0.10 The safety measures for application and maintenance must be taken in the reclaimed water engineering design. The reclaimed water is strictly forbidden to enter the drinking water supply system. 1.0.11 The reclaimed water system design in the building shall meet the requirements of current relevant compulsary codes and standards except the implementation of this Code.
Contents Foreword I 1 General Provisions 2 Terms and Symbols 2.1 Terms 2.2 Symbols 3 Reclaimed Water Source 3.1 Water Source of Reclaimed Water System for Building 3.2 Water Resource of Reclaimed Water System for Building Area 4 Reclaimed Water Quality Standard 4.1 Reclaimed Water Utilization 4.2 Reclaimed Water Quality Standard 5 Reclaimed Water System 5.1 Reclaimed Water System Type 5.2 Raw-water System 5.3 Water Balance 5.4 The Water Supply System Of The Reclaimed Water 6 Treatment Process and Facility 6.1 Treatment Process 6.2 Treatment Facilities 7 Reclaimed Water's Treatment Plant 8 Safety Protection and Supervision (Inspection) Control 8.1 Safety Protection 8.2 Supervision (Inspection) Control Explanation of Wording in This Code
GB 50336-2002 is referred in:
* GB 50555-2010 Standard for water saving design in civil building
* GB 50555-2010 Standard for water saving design in civil building
Code of China
Standard
GB 50336-2002   Code of design for building reclaimed water system (English Version)
Standard No.GB 50336-2002
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count7000 words
Price(USD)170.0
Implemented on2003-3-1
Deliveryvia email in 1 business day
Detail of GB 50336-2002
Standard No.
GB 50336-2002
English Name
Code of design for building reclaimed water system
Chinese Name
建筑中水设计规范
Chinese Classification
P40
Professional Classification
GB
ICS Classification
Issued by
NDRC
Issued on
2003-1-10
Implemented on
2003-3-1
Status
superseded
Superseded by
GB 50336-2018 Standard for design of building reclaimed water system
Superseded on
2018-12-1
Abolished on
Superseding
CECS 30-1991
Language
English
File Format
PDF
Word Count
7000 words
Price(USD)
170.0
Keywords
GB 50336-2002, GB/T 50336-2002, GBT 50336-2002, GB50336-2002, GB 50336, GB50336, GB/T50336-2002, GB/T 50336, GB/T50336, GBT50336-2002, GBT 50336, GBT50336
Introduction of GB 50336-2002
1 General Provisions 1.0.1 This code is formulated to realize sewage, wastewater recycling, water saving, pollution governing and environment protection and to make the design for building reclaimed water engineering safe, reliable, economic, applicable and advanced in technology. 1.0.2 This code is applicable to the constructed, renovated and extended reclaimed water engineering design of the various civil building and residential are. The reclaimed water engineering design of the domestic sewage and wastewater reutilization in industrial building may be executed with reference to this code. 1.0.3 Various sewage, wastewater resources shall be taken full advantage of according to the local water resource situation and economic development level. 1.0.4 Where various structures and residential areas are constructed in the city and other regions in water shortage, the overall planning design shall include the comprehensive utilization and reclaimed water facility construction of sewage, wastewater and rainwater resources. 1.0.5 The reclaimed water facility engineering projects are applicable to the cities and other regions in water shortage. The reclaimed water facilities shall be constructed according to the local regulations. Reclaimed water facilities must be designed together with the main works. They must be constructed and applied at the same time. 1.0.6 As for the reclaimed water engineering design, water balance and technical and economic analysis shall be executed according to the water quality , water quantity and reclaimed water purposes of the available raw water, to determine the reclaimed water source, systematic type, treatment process and scale reasonably. 1.0.7 The reclaimed water engineering design shall be in the charge of the design organization of the main works. The design schedule of the reclaimed engineering shall be in compliance with the design schedule of the main works, and the design depth at different stages shall meet the requirements of the preparation depth relevant architectonic engineering design documents. 1.0.8 The reclaimed water engineering design quality shall meet the requirements of the quality characteristic and quality evaluation enforcement regulations of the national design document on civil building engineering. 1.0.9 The acceptable age limit of the reclaimed water facilities shall be in conformity of the main building design criteria. 1.0.10 The safety measures for application and maintenance must be taken in the reclaimed water engineering design. The reclaimed water is strictly forbidden to enter the drinking water supply system. 1.0.11 The reclaimed water system design in the building shall meet the requirements of current relevant compulsary codes and standards except the implementation of this Code.
Contents of GB 50336-2002
Contents Foreword I 1 General Provisions 2 Terms and Symbols 2.1 Terms 2.2 Symbols 3 Reclaimed Water Source 3.1 Water Source of Reclaimed Water System for Building 3.2 Water Resource of Reclaimed Water System for Building Area 4 Reclaimed Water Quality Standard 4.1 Reclaimed Water Utilization 4.2 Reclaimed Water Quality Standard 5 Reclaimed Water System 5.1 Reclaimed Water System Type 5.2 Raw-water System 5.3 Water Balance 5.4 The Water Supply System Of The Reclaimed Water 6 Treatment Process and Facility 6.1 Treatment Process 6.2 Treatment Facilities 7 Reclaimed Water's Treatment Plant 8 Safety Protection and Supervision (Inspection) Control 8.1 Safety Protection 8.2 Supervision (Inspection) Control Explanation of Wording in This Code
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 50336-2002, GB/T 50336-2002, GBT 50336-2002, GB50336-2002, GB 50336, GB50336, GB/T50336-2002, GB/T 50336, GB/T50336, GBT50336-2002, GBT 50336, GBT50336