2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 50745-2012
GB 50745-2012   Code for design of fire protection for conventiontional island in nuclear power plants (English Version)
Standard No.: GB 50745-2012 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 13000 words Translation Price(USD):260.0 remind me the price change

Email:

Implemented on:2012-10-1 Delivery: via email in 1 business day

→ → →

,,2012-10-1,14113818192110E67F6B7B2181A67
Standard No.: GB 50745-2012
English Name: Code for design of fire protection for conventiontional island in nuclear power plants
Chinese Name: 核电厂常规岛设计防火规范
Professional Classification: GB    National Standard
Source Content Issued by: MOHURD
Issued on: 2012-01-21
Implemented on: 2012-10-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 13000 words
Translation Price(USD): 260.0
Delivery: via email in 1 business day
1 General Provisions 1.0.1 This code is formulated with a view to preventing fire in conventional island in nuclear power plants, reducing fire hazards as well as guaranteeing personal safety, property safety and safety of nuclear power plants. 1.0.2 This code is applicable to fire protection design for conventional island in pressurized water reactor plant with unit capacity of steam turbine generator up to and including mega-kilowatt class. 1.0.3 Design of fire protection for conventional island shall implement the national relevant guidelines and policies, to give overall consideration, to achieve safety, reliability and advanced technology, and to be economic and applicable. 1.0.4 Design of fire protection for conventional island in nuclear power plants shall not only meet the requirements of this code but also comply with those in the current relevant ones of the nation. 2 Terms 2.0.1 Conventional island A general term of steam turbine generators and their supporting facilities and buildings (structures) 2.0.2 Turbine building Building complex composed of turbine house, deaerator bay, condensate polishing room and lubricating oil transfer room 2.0.3 Main switchgear station High-voltage electrical installations and buildings (structures) for conveying electrical energy to the power grid and providing normal-start power supply to the units 2.0.4 Auxiliary switchgear station High-voltage electrical installations and buildings (structures) for providing normal standby and maintenance power supply to the auxiliary power system 2.0.5 Switchgear control building Building that controls the main electrical equipment in main switchgear station and auxiliary switchgear station 2.0.6 Auxiliary boiler house Building complex, mainly auxiliary boiler room, for providing auxiliary steam to startup or shutdown of steam turbine generators 3 Classification of Fire Hazards and Fire Resistance Class of Buildings (Structures) 3.0.1 Classification of fire hazards and fire resistance class of buildings (structures) shall not be lower than those specified in Table 3.0.1.
Contents 1 General Provisions 2 Terms 3 Classification of Fire Hazards and Fire Resistance Class of Buildings (Structures) 4 General Plane Layout 5 Fire Compartment, Safe Evacuation of Buildings (Structures) and Building Structure 5.1 Fire Compartment of Buildings (Structures) 5.2 Safe Evacuation of Factory Buildings and Storages 5.3 Building Structure 6 Process System 6.1 Steam Turbine Generator 6.2 Area of Fuel Oil Tank and Oil Pump House 6.3 Transformer 6.4 Cable and Cable Laying 7 Fire Water Supply, Fire Extinguishing Facilities and Fire Alarm 7.1 General Requirement 7.2 Outdoor Water Supply for Firefighting 7.3 Arrangement and Fire Flow Rates of Indoor Hydrant 7.4 Indoor Fire Water Pipe and Hydrant 7.5 Water Spray Extinguishing System and Water Sprinkler System 7.6 Fire Water Discharge 7.7 Foam Extinguishing System 7.8 Gas Extinguishing System 7.9 Fire Extinguisher 7.10 Automatic Fire Alarm and Fire Facilities Control 8 Heating, Ventilating and Air Conditioning 8.1 Heating 8.2 Ventilating 8.3 Smoke Control and Smoke Exhaust 8.4 Air Conditioning 9 Fire Power Supply and Lighting 9.1 Fire Power Supply 9.2 Lighting Explanation of Wording in This Code List of Quoted Standards
Referred in GB 50745-2012:

GB 50745-2012 is referred in:
*GB 50217-2018 Standard for design of cables of electric power engineering
*GB/T 22158-2021 Code for fire protection design of nuclear power plant
Code of China
Standard
GB 50745-2012  Code for design of fire protection for conventiontional island in nuclear power plants (English Version)
Standard No.GB 50745-2012
Statusvalid
LanguageEnglish
File FormatPDF
Word Count13000 words
Price(USD)260.0
Implemented on2012-10-1
Deliveryvia email in 1 business day
Detail of GB 50745-2012
Standard No.
GB 50745-2012
English Name
Code for design of fire protection for conventiontional island in nuclear power plants
Chinese Name
核电厂常规岛设计防火规范
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
MOHURD
Issued on
2012-01-21
Implemented on
2012-10-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
13000 words
Price(USD)
260.0
Keywords
GB 50745-2012, GB/T 50745-2012, GBT 50745-2012, GB50745-2012, GB 50745, GB50745, GB/T50745-2012, GB/T 50745, GB/T50745, GBT50745-2012, GBT 50745, GBT50745
Introduction of GB 50745-2012
1 General Provisions 1.0.1 This code is formulated with a view to preventing fire in conventional island in nuclear power plants, reducing fire hazards as well as guaranteeing personal safety, property safety and safety of nuclear power plants. 1.0.2 This code is applicable to fire protection design for conventional island in pressurized water reactor plant with unit capacity of steam turbine generator up to and including mega-kilowatt class. 1.0.3 Design of fire protection for conventional island shall implement the national relevant guidelines and policies, to give overall consideration, to achieve safety, reliability and advanced technology, and to be economic and applicable. 1.0.4 Design of fire protection for conventional island in nuclear power plants shall not only meet the requirements of this code but also comply with those in the current relevant ones of the nation. 2 Terms 2.0.1 Conventional island A general term of steam turbine generators and their supporting facilities and buildings (structures) 2.0.2 Turbine building Building complex composed of turbine house, deaerator bay, condensate polishing room and lubricating oil transfer room 2.0.3 Main switchgear station High-voltage electrical installations and buildings (structures) for conveying electrical energy to the power grid and providing normal-start power supply to the units 2.0.4 Auxiliary switchgear station High-voltage electrical installations and buildings (structures) for providing normal standby and maintenance power supply to the auxiliary power system 2.0.5 Switchgear control building Building that controls the main electrical equipment in main switchgear station and auxiliary switchgear station 2.0.6 Auxiliary boiler house Building complex, mainly auxiliary boiler room, for providing auxiliary steam to startup or shutdown of steam turbine generators 3 Classification of Fire Hazards and Fire Resistance Class of Buildings (Structures) 3.0.1 Classification of fire hazards and fire resistance class of buildings (structures) shall not be lower than those specified in Table 3.0.1.
Contents of GB 50745-2012
Contents 1 General Provisions 2 Terms 3 Classification of Fire Hazards and Fire Resistance Class of Buildings (Structures) 4 General Plane Layout 5 Fire Compartment, Safe Evacuation of Buildings (Structures) and Building Structure 5.1 Fire Compartment of Buildings (Structures) 5.2 Safe Evacuation of Factory Buildings and Storages 5.3 Building Structure 6 Process System 6.1 Steam Turbine Generator 6.2 Area of Fuel Oil Tank and Oil Pump House 6.3 Transformer 6.4 Cable and Cable Laying 7 Fire Water Supply, Fire Extinguishing Facilities and Fire Alarm 7.1 General Requirement 7.2 Outdoor Water Supply for Firefighting 7.3 Arrangement and Fire Flow Rates of Indoor Hydrant 7.4 Indoor Fire Water Pipe and Hydrant 7.5 Water Spray Extinguishing System and Water Sprinkler System 7.6 Fire Water Discharge 7.7 Foam Extinguishing System 7.8 Gas Extinguishing System 7.9 Fire Extinguisher 7.10 Automatic Fire Alarm and Fire Facilities Control 8 Heating, Ventilating and Air Conditioning 8.1 Heating 8.2 Ventilating 8.3 Smoke Control and Smoke Exhaust 8.4 Air Conditioning 9 Fire Power Supply and Lighting 9.1 Fire Power Supply 9.2 Lighting Explanation of Wording in This Code List of Quoted Standards
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 50745-2012, GB/T 50745-2012, GBT 50745-2012, GB50745-2012, GB 50745, GB50745, GB/T50745-2012, GB/T 50745, GB/T50745, GBT50745-2012, GBT 50745, GBT50745