GB 7251.6-2015   Low-voltage switchgear and controlgear assemblies―Part 6:Busbar trunking systems(busways) (English Version)
Standard No.: GB 7251.6-2015 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 12000 words Translation Price(USD):140.0 remind me the price change

Email:

Implemented on:2016-6-1 Delivery: via email in 1 business day

→ → →

,,2016-6-1,14434306163940001b2349d8d247d8d2
Standard No.: GB 7251.6-2015
English Name: Low-voltage switchgear and controlgear assemblies―Part 6:Busbar trunking systems(busways)
Chinese Name: 低压成套开关设备和控制设备 第6部分:母线干线系统(母线槽)
Chinese Classification: K31    Low-voltage distribution electrical equipment
Professional Classification: GB    National Standard
ICS Classification: 29.130.20 29.130.20     Low voltage switchgear and controlgear 29.130.20
Source Content Issued by: AQSIQ; SAC
Issued on: 2015-05-15
Implemented on: 2016-6-1
Status: valid
Superseding:GB 7251.2-2006 Low-voltage Switchgear and Controlgear Assemblies - Part 2: Particular Requirements for Busbar Trunking Systems (Busways)
Target Language: English
File Format: PDF
Word Count: 12000 words
Translation Price(USD): 140.0
Delivery: via email in 1 business day
1 Scope Note 1: the abbreviation BTS used throughout this part refers to busbar trunking system. As for Part 1, the term "assembly" is referred to as "BTS" for short. This part of GB 7251 specifies the definitions, service conditions, structural requirements, technical characteristics and verification requirements of the following low-voltage assembly (see 3.101): - The assembly with the rated AC voltage not exceeding 1000V and the rated DC voltage not exceeding 1500V; - Assembly used with power generation, power transmission, power distribution, electric energy conversion and power consumption control equipment; - Assembly designed for special conditions, such as ships, railway and civil appliance (operated by non-professional personnel) as long as it meets the relevant specific requirements; Note 2: IEC 60092-302 includes the supplementary requirements of assemblies for ships. - For assembly designed for electrical equipment of machine, IEC 60204 includes the supplementary requirements of assemblies constituting the constituent part of the machine. This part is applicable to all assemblies designed, manufactured and inspected at one time or those totally under standardized batch manufacturing. The original manufacturer may not be responsible for the production and/or assembling (see 3.10.1 and 3.10.2 in Part 1). This part is not applicable to the separate device and self-contained component meeting their respective product standards, such as motor starter, fuse switch and electronic equipment. This part is not applicable to specific assemblies in other parts of GB 7251, electrical supply track systems in GB 13961-2008, cable trunking and ducting systems in GB/T 19215 (All Parts) and power track systems in IEC 61534 (All Parts). 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendments) applies. In addition to the following contents, Chapter 2 in GB 7251.1-2013 also applies. Add: GB 7251.1-2013 Low-voltage Switchgear and Controlgear Assemblies - Part 1: General Rules (IEC 61439-1:2011, IDT) GB/T 18380.31-2008 Test on Electric and Optical Fiber Cables under Fire Conditions - Part 31: Test for Vertical Flame Spread of Vertically-mounted Bunched Wires or Cables - Apparatus (IEC 60332-3-10:2000, IDT) IEC 60439-2:2000 Low-voltage Switchgear and Controlgear Assemblies - Part 2: Particular Requirements for Busbar Trunking Systems (Busways) [Low-voltage Switchgear and Controlgear Assemblies - Part 2: Particular Requirements for Busbar Trunking Systems (Busways)] IEC 61786:1998 Measurement of Low-frequency Magnetic and Electric Fields with Regard to Exposure of Human Beings - Special Requirements for Instruments and Guidance for Measurements ISO 834-1:1999 Fire-resistance Tests - Elements of Building Construction - Part 1: General Requirements 3 Terms and Definitions In addition to the following contents, Chapter 3 in GB 7251.1-2013 also applies. Add definitions: 3.101 Busbar trunking systems; BTS Busways The enclosed assembly composed of conductor system, used for power distribution and electricity control of all loads and applicable to industrial, commercial and similar purposes. This conductor system is composed of busbars separated or supported by the insulating material in pipeline, slot or similar enclosure. [Source: the revised IEC 60050-441:1984, 441-12-07] Note 1: see 3.1.1 in GB 7251.1-2013 for the definition of assembly. Note 2: BTS may be composed of a series of mechanical and electrical elements, e.g.: - BTU with or without tap-off facility; - Phase transposition, expansion, flexible, feeder and adapter units; - Tap-off unit; - Additional conductors for communication and/or control. Note 3: for the term "busbar", the geometrical shape, dimension and area of conductor are not preset. 3.102 Busbar trunking unit; BTU A unit of BTS. This unit is composed of busbar, busbar supporting part and insulating part, enclosure and fixed part and connected part connecting other units. It may or may not be equipped with tap-off facility. Note: busbar trunking may have different geometrical shapes such as straight, elbow, tee or cross. 3.103 Busbar trunking run; BT run Multiple BTUs (excluding tap-off unit) connected together to constitute the BTS. 3.104 Busbar trunking unit with tap-off facilities; BTU with tap-off facilities BTU prefabricated by the original manufacturer designed to enable tap-off units to be installed at one or more points. 3.105 Busbar trunking unit with trolley-type tap-off facilities; BTU with trolley-type tap-off facilities BTU designed to permit the use of roller- or trolley-type tap-off units. 3.106 Busbar trunking adapter unit; adapter BTU BTU intended to connect two units of the same system but of different types or different rated currents. 3.107 Busbar trunking thermal expansion unit; thermal expansion BTU BTU intended to permit a certain movement in the axial direction of the BT run due to thermal expansion of the system. Note: this term doesn't preset the part allowed to move, e.g. the conductor in enclosure or both the conductor and enclosure. 3.108 Busbar trunking phase transposition unit; phase transposition BTU BTU intended to change the relative position of the phase conductor in order to balance the inductive reactance or to transpose the phases (such as L1-L2-L3-N to N-L3-L2-L1). 3.109 Flexible busbar trunking unit; flexible BTU BTU having conductor and enclosure designed to be under assigned direction conversion during installation. 3.110 Busbar trunking feeder unit; feeder BTU BTU serving as an incoming unit. Note: see 3.1.9 in GB 7251.1-2013 for the definition of incoming unit. 3.111 Tap-off unit Outgoing unit, either stationary or movable, which is tapped off from BTU. Note 1: see 3.1.10, 3.2.1 and 3.2.2 in GB 7251.1-2013 for the definitions of outgoing unit, fixed part and removable part. Note 2: inserted tap-off unit is a kind of movable tap-off unit which may be manually connected and separated (see 8.5.2). 3.112 Busbar trunking unit for building movements; BTU for building movements BTU intended to allow for building movements due to thermal expansion, contraction and/or flection. 3.113 Busbar trunking fire barrier unit; fire barrier BTU BTU or a part of it intended to prevent the flame spread throughout a building structure within specified time under fire conditions.
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Symbols and Abbreviations 5 Interface Characteristics 6 Information 7 Service Conditions 8 Structural Requirements 9 Performance Requirements 10 Design Verification 11 Routine Inspection Appendix Appendix C (Informative) Table of Specification Appendix D (Informative) Design Verification Appendix AA (Informative) System Voltage Drop Appendix BB (Informative) Characteristics of Phase Conductors Appendix CC (Informative) Fault Zero Sequence Impedance Appendix DD (Informative) Resistance and Reactance of Fault Circuit Appendix EE (Informative) Determination of Magnetic Field Surrounding BTS Bibliography Figure 101 Mechanical Load Test of Straight Unit Figure 102 Mechanical Load Test of Connecting Points Figure 103 Test Arrangement for Verification of Flame Barrier BTU Figure BB.1 Determination of Characteristics of Phase Conductors Figure CC.1 Determination of Fault Zero Sequence Impedance Figure DD.1 Determination of Resistance and Reactance of Fault Circuit Figure EE.1 Arrangement of Magnetic Field Measurement Table 101 Rated Dispersion factor of Tap-off Unit Table 102 Characteristics of Phase Conductor Table 103 Characteristics of Fault Circuit Table 104 Characteristics Used for Fault Current Calculation Table 105 Thermal Cycling Test Conditions Table C.1 Table of User Specification Table D.1 Design Verification
Referred in GB 7251.6-2015:
*GB 7251.1-2013 Low-voltage switchgear and controlgear assemblies-Part 1:General rules
*GB/T 18380.31-2008 Test on electric and optical fibre cables under fire conditions - Part 31: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
Code of China
Standard
GB 7251.6-2015  Low-voltage switchgear and controlgear assemblies―Part 6:Busbar trunking systems(busways) (English Version)
Standard No.GB 7251.6-2015
Statusvalid
LanguageEnglish
File FormatPDF
Word Count12000 words
Price(USD)140.0
Implemented on2016-6-1
Deliveryvia email in 1 business day
Detail of GB 7251.6-2015
Standard No.
GB 7251.6-2015
English Name
Low-voltage switchgear and controlgear assemblies―Part 6:Busbar trunking systems(busways)
Chinese Name
低压成套开关设备和控制设备 第6部分:母线干线系统(母线槽)
Chinese Classification
K31
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2015-05-15
Implemented on
2016-6-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 7251.2-2006 Low-voltage Switchgear and Controlgear Assemblies - Part 2: Particular Requirements for Busbar Trunking Systems (Busways)
Language
English
File Format
PDF
Word Count
12000 words
Price(USD)
140.0
Keywords
GB 7251.6-2015, GB/T 7251.6-2015, GBT 7251.6-2015, GB7251.6-2015, GB 7251.6, GB7251.6, GB/T7251.6-2015, GB/T 7251.6, GB/T7251.6, GBT7251.6-2015, GBT 7251.6, GBT7251.6
Introduction of GB 7251.6-2015
1 Scope Note 1: the abbreviation BTS used throughout this part refers to busbar trunking system. As for Part 1, the term "assembly" is referred to as "BTS" for short. This part of GB 7251 specifies the definitions, service conditions, structural requirements, technical characteristics and verification requirements of the following low-voltage assembly (see 3.101): - The assembly with the rated AC voltage not exceeding 1000V and the rated DC voltage not exceeding 1500V; - Assembly used with power generation, power transmission, power distribution, electric energy conversion and power consumption control equipment; - Assembly designed for special conditions, such as ships, railway and civil appliance (operated by non-professional personnel) as long as it meets the relevant specific requirements; Note 2: IEC 60092-302 includes the supplementary requirements of assemblies for ships. - For assembly designed for electrical equipment of machine, IEC 60204 includes the supplementary requirements of assemblies constituting the constituent part of the machine. This part is applicable to all assemblies designed, manufactured and inspected at one time or those totally under standardized batch manufacturing. The original manufacturer may not be responsible for the production and/or assembling (see 3.10.1 and 3.10.2 in Part 1). This part is not applicable to the separate device and self-contained component meeting their respective product standards, such as motor starter, fuse switch and electronic equipment. This part is not applicable to specific assemblies in other parts of GB 7251, electrical supply track systems in GB 13961-2008, cable trunking and ducting systems in GB/T 19215 (All Parts) and power track systems in IEC 61534 (All Parts). 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendments) applies. In addition to the following contents, Chapter 2 in GB 7251.1-2013 also applies. Add: GB 7251.1-2013 Low-voltage Switchgear and Controlgear Assemblies - Part 1: General Rules (IEC 61439-1:2011, IDT) GB/T 18380.31-2008 Test on Electric and Optical Fiber Cables under Fire Conditions - Part 31: Test for Vertical Flame Spread of Vertically-mounted Bunched Wires or Cables - Apparatus (IEC 60332-3-10:2000, IDT) IEC 60439-2:2000 Low-voltage Switchgear and Controlgear Assemblies - Part 2: Particular Requirements for Busbar Trunking Systems (Busways) [Low-voltage Switchgear and Controlgear Assemblies - Part 2: Particular Requirements for Busbar Trunking Systems (Busways)] IEC 61786:1998 Measurement of Low-frequency Magnetic and Electric Fields with Regard to Exposure of Human Beings - Special Requirements for Instruments and Guidance for Measurements ISO 834-1:1999 Fire-resistance Tests - Elements of Building Construction - Part 1: General Requirements 3 Terms and Definitions In addition to the following contents, Chapter 3 in GB 7251.1-2013 also applies. Add definitions: 3.101 Busbar trunking systems; BTS Busways The enclosed assembly composed of conductor system, used for power distribution and electricity control of all loads and applicable to industrial, commercial and similar purposes. This conductor system is composed of busbars separated or supported by the insulating material in pipeline, slot or similar enclosure. [Source: the revised IEC 60050-441:1984, 441-12-07] Note 1: see 3.1.1 in GB 7251.1-2013 for the definition of assembly. Note 2: BTS may be composed of a series of mechanical and electrical elements, e.g.: - BTU with or without tap-off facility; - Phase transposition, expansion, flexible, feeder and adapter units; - Tap-off unit; - Additional conductors for communication and/or control. Note 3: for the term "busbar", the geometrical shape, dimension and area of conductor are not preset. 3.102 Busbar trunking unit; BTU A unit of BTS. This unit is composed of busbar, busbar supporting part and insulating part, enclosure and fixed part and connected part connecting other units. It may or may not be equipped with tap-off facility. Note: busbar trunking may have different geometrical shapes such as straight, elbow, tee or cross. 3.103 Busbar trunking run; BT run Multiple BTUs (excluding tap-off unit) connected together to constitute the BTS. 3.104 Busbar trunking unit with tap-off facilities; BTU with tap-off facilities BTU prefabricated by the original manufacturer designed to enable tap-off units to be installed at one or more points. 3.105 Busbar trunking unit with trolley-type tap-off facilities; BTU with trolley-type tap-off facilities BTU designed to permit the use of roller- or trolley-type tap-off units. 3.106 Busbar trunking adapter unit; adapter BTU BTU intended to connect two units of the same system but of different types or different rated currents. 3.107 Busbar trunking thermal expansion unit; thermal expansion BTU BTU intended to permit a certain movement in the axial direction of the BT run due to thermal expansion of the system. Note: this term doesn't preset the part allowed to move, e.g. the conductor in enclosure or both the conductor and enclosure. 3.108 Busbar trunking phase transposition unit; phase transposition BTU BTU intended to change the relative position of the phase conductor in order to balance the inductive reactance or to transpose the phases (such as L1-L2-L3-N to N-L3-L2-L1). 3.109 Flexible busbar trunking unit; flexible BTU BTU having conductor and enclosure designed to be under assigned direction conversion during installation. 3.110 Busbar trunking feeder unit; feeder BTU BTU serving as an incoming unit. Note: see 3.1.9 in GB 7251.1-2013 for the definition of incoming unit. 3.111 Tap-off unit Outgoing unit, either stationary or movable, which is tapped off from BTU. Note 1: see 3.1.10, 3.2.1 and 3.2.2 in GB 7251.1-2013 for the definitions of outgoing unit, fixed part and removable part. Note 2: inserted tap-off unit is a kind of movable tap-off unit which may be manually connected and separated (see 8.5.2). 3.112 Busbar trunking unit for building movements; BTU for building movements BTU intended to allow for building movements due to thermal expansion, contraction and/or flection. 3.113 Busbar trunking fire barrier unit; fire barrier BTU BTU or a part of it intended to prevent the flame spread throughout a building structure within specified time under fire conditions.
Contents of GB 7251.6-2015
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Symbols and Abbreviations 5 Interface Characteristics 6 Information 7 Service Conditions 8 Structural Requirements 9 Performance Requirements 10 Design Verification 11 Routine Inspection Appendix Appendix C (Informative) Table of Specification Appendix D (Informative) Design Verification Appendix AA (Informative) System Voltage Drop Appendix BB (Informative) Characteristics of Phase Conductors Appendix CC (Informative) Fault Zero Sequence Impedance Appendix DD (Informative) Resistance and Reactance of Fault Circuit Appendix EE (Informative) Determination of Magnetic Field Surrounding BTS Bibliography Figure 101 Mechanical Load Test of Straight Unit Figure 102 Mechanical Load Test of Connecting Points Figure 103 Test Arrangement for Verification of Flame Barrier BTU Figure BB.1 Determination of Characteristics of Phase Conductors Figure CC.1 Determination of Fault Zero Sequence Impedance Figure DD.1 Determination of Resistance and Reactance of Fault Circuit Figure EE.1 Arrangement of Magnetic Field Measurement Table 101 Rated Dispersion factor of Tap-off Unit Table 102 Characteristics of Phase Conductor Table 103 Characteristics of Fault Circuit Table 104 Characteristics Used for Fault Current Calculation Table 105 Thermal Cycling Test Conditions Table C.1 Table of User Specification Table D.1 Design Verification
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 7251.6-2015, GB/T 7251.6-2015, GBT 7251.6-2015, GB7251.6-2015, GB 7251.6, GB7251.6, GB/T7251.6-2015, GB/T 7251.6, GB/T7251.6, GBT7251.6-2015, GBT 7251.6, GBT7251.6