2025-12-15 216.73.216.89
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 10264-1988
GB/T 10264-1988   Thermoluminescence dosimetry for personal and environmental monitoring (English Version)
Standard No.: GB/T 10264-1988 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 13000 words Translation Price(USD):180.0 remind me the price change

Email:

Implemented on:1989-10-1 Delivery: via email in 1 business day

→ → →

,2015-2-1,1989-10-1,14113813343935C0AE4474EEF9332
Standard No.: GB/T 10264-1988
English Name: Thermoluminescence dosimetry for personal and environmental monitoring
Chinese Name: 个人和环境监测用热释光剂量测量系统
Professional Classification: GB    National Standard
Source Content Issued by: AQSIQ
Issued on: 1988-1-2
Implemented on: 1989-10-1
Status: superseded
Superseded by:GB/T 10264-2014 Thermoluminescence dosimetry systems for personal and environmental monitoring
Superseded on:2015-2-1
Target Language: English
File Format: PDF
Word Count: 13000 words
Translation Price(USD): 180.0
Delivery: via email in 1 business day
This standard specifies the classification, symbols, performance criteria and corresponding test rules of the measuring system, detector and reader of thermoluminescence radiation dose used for personal and environmental monitoring, however, it does not cover the parts of information access and data processing. The thermoluminescence dosimetry system is mainly composed of the following parts: a. The passive device refer to dosemeter, it contains one or more detectors showing the thermoluminescence characteristics and is set with some kind of recognition method. b. The reader is used to heat the detector that has been exposed to the ionizing radiation and to measure out the light output of detector simultaneously so as to measure the corresponding radiation dose. c. Other optional equipments and operational procedures are used for carrying out necessary auxiliary processes such as annealing and cleaning so as to guarantee the efficiency of the overall system. d. The data processing procedure is used to convert the measured light output to dose so as to obtain the result. This standard respectively establishes the clauses on examining the performance of the whole thermoluminescence dosimetry system, detector or reader. Whereas, it does not include special provisions on the examination of the aforementioned Item c and Item d, Item c and Item d will only be taken as a part of indirect examination of the thermoluminescence dosimetry system. The contents of the performance criteria of Thermoluminescence dosimetry system are most comprehensive, the design makes those systems meeting this standard be able to meet the requirements of modern science and technology levels on the measurement of personal and environmental dose. The performance criteria used for separate examination of detector only includes those contents that obviously depend mainly on detector instead of the influence of other necessity parts in the examination. Here, the criteria only make sense to detectors but is irrelevant to the rest parts used as one integrated system. And this principle also may be implemented when examining the reader separately. Even if the detector or reader meets their own performance criteria, it can not be guaranteed that any system including these parts meets the criteria of thermoluminescence dosimetry system.
Chapter 1 1 Subject Content and Application Scope 2 Measurement Object 3 Definitions 4 Units 5 Classification and Symbols Chapter 2 6 Performance Requirements 7 Test Rules Chapter 3 8 Quality Certificate of Product 9 Power Supply 10 Instruction Manual 11 Marking and Packing Annex A Dose Equivalent Conversion Factor for Personal Dosemeter (Informative) Annex B Dose Equivalent Conversion Factor for Environmental Dosemeter (Informative) Annex C Calculation of Evaluated Value (E) with Readout Value (r) (Informative) Annex D Confidence Limit (Informative)
Code of China
Standard
GB/T 10264-1988  Thermoluminescence dosimetry for personal and environmental monitoring (English Version)
Standard No.GB/T 10264-1988
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count13000 words
Price(USD)180.0
Implemented on1989-10-1
Deliveryvia email in 1 business day
Detail of GB/T 10264-1988
Standard No.
GB/T 10264-1988
English Name
Thermoluminescence dosimetry for personal and environmental monitoring
Chinese Name
个人和环境监测用热释光剂量测量系统
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
AQSIQ
Issued on
1988-1-2
Implemented on
1989-10-1
Status
superseded
Superseded by
GB/T 10264-2014 Thermoluminescence dosimetry systems for personal and environmental monitoring
Superseded on
2015-2-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
13000 words
Price(USD)
180.0
Keywords
GB/T 10264-1988, GB 10264-1988, GBT 10264-1988, GB/T10264-1988, GB/T 10264, GB/T10264, GB10264-1988, GB 10264, GB10264, GBT10264-1988, GBT 10264, GBT10264
Introduction of GB/T 10264-1988
This standard specifies the classification, symbols, performance criteria and corresponding test rules of the measuring system, detector and reader of thermoluminescence radiation dose used for personal and environmental monitoring, however, it does not cover the parts of information access and data processing. The thermoluminescence dosimetry system is mainly composed of the following parts: a. The passive device refer to dosemeter, it contains one or more detectors showing the thermoluminescence characteristics and is set with some kind of recognition method. b. The reader is used to heat the detector that has been exposed to the ionizing radiation and to measure out the light output of detector simultaneously so as to measure the corresponding radiation dose. c. Other optional equipments and operational procedures are used for carrying out necessary auxiliary processes such as annealing and cleaning so as to guarantee the efficiency of the overall system. d. The data processing procedure is used to convert the measured light output to dose so as to obtain the result. This standard respectively establishes the clauses on examining the performance of the whole thermoluminescence dosimetry system, detector or reader. Whereas, it does not include special provisions on the examination of the aforementioned Item c and Item d, Item c and Item d will only be taken as a part of indirect examination of the thermoluminescence dosimetry system. The contents of the performance criteria of Thermoluminescence dosimetry system are most comprehensive, the design makes those systems meeting this standard be able to meet the requirements of modern science and technology levels on the measurement of personal and environmental dose. The performance criteria used for separate examination of detector only includes those contents that obviously depend mainly on detector instead of the influence of other necessity parts in the examination. Here, the criteria only make sense to detectors but is irrelevant to the rest parts used as one integrated system. And this principle also may be implemented when examining the reader separately. Even if the detector or reader meets their own performance criteria, it can not be guaranteed that any system including these parts meets the criteria of thermoluminescence dosimetry system.
Contents of GB/T 10264-1988
Chapter 1 1 Subject Content and Application Scope 2 Measurement Object 3 Definitions 4 Units 5 Classification and Symbols Chapter 2 6 Performance Requirements 7 Test Rules Chapter 3 8 Quality Certificate of Product 9 Power Supply 10 Instruction Manual 11 Marking and Packing Annex A Dose Equivalent Conversion Factor for Personal Dosemeter (Informative) Annex B Dose Equivalent Conversion Factor for Environmental Dosemeter (Informative) Annex C Calculation of Evaluated Value (E) with Readout Value (r) (Informative) Annex D Confidence Limit (Informative)
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 10264-1988, GB 10264-1988, GBT 10264-1988, GB/T10264-1988, GB/T 10264, GB/T10264, GB10264-1988, GB 10264, GB10264, GBT10264-1988, GBT 10264, GBT10264