GB/T 14542-2017   Guide for maintenance and supervision of transformer oil (English Version)
Standard No.: GB/T 14542-2017 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 10500 words Translation Price(USD):260.0 remind me the price change

Email:

Implemented on:2017-12-1 Delivery: via email in 1 business day

→ → →

,,2017-12-1,2B6DE4E830C5E0D71501161147620
Standard No.: GB/T 14542-2017
English Name: Guide for maintenance and supervision of transformer oil
Chinese Name: 变压器油维护管理导则
Chinese Classification: F24    Electric power testing technique
Professional Classification: GB    National Standard
Source Content Issued by: MOHURD; AQSIQ
Issued on: 2017-05-12
Implemented on: 2017-12-1
Status: valid
Superseding:GB/T 14542-2005 Guide for maintenance and supervision of transformer oil in service
Target Language: English
File Format: PDF
Word Count: 10500 words
Translation Price(USD): 260.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB/T 14542-2005 Guide for maintenance and supervision of transformer oil in service, and has the following main technical changes, in addition to editorial changes, made with respect to GB/T 14542-2005: —The standard name has been changed to Guide for maintenance and supervision of transformer oil; —The application scope of the standard has been modified; —The normative references have been modified; —The terms and definitions have been introduced; —The contents in the clause of sampling have been simplified; —The inspection items and quality criteria for oil after new oil purification and hot oil circulation have been modified; —The quality criteria and inspection frequency of in-service transformer oil have been modified, and items including color, gassing, charging tendency, corrosive sulfur, particulate contamination, antioxidant additive content, furfural content and DBDS content have been introduced; —The interpretation of test results has been deleted; —The causes for in-service transformer oil exceeding limits and actions taken have been modified, and limits, possible causes and countermeasures of corrosive sulfur, particulate contamination, furfural content and DBDS content have been introduced; —The oil compatibility (oil mixing) has been modified; —The contents of the clauses regarding anti-aging measures for in-service oil and oil treatment have been consolidated and modified, and the title has been changed to "Maintenance of in-service transformer oil"; —The contents of the clause regarding of oil storage, transportation and technical management have been modified; —The informative Annex A has been deleted. —The contents in Annex B of the original standard have been modified. This standard was prepared using the redrafting method with reference to IEC 60422:2013 Mineral insulating oils in electrical equipment—Supervision and maintenance guidance, and is not equivalent to IEC 60422:2013. This standard was proposed by the China Electricity Council (CEC). This standard is under the jurisdiction of the National Technical Committee on Electrochemistry of Standardization Administration of China (SAC/TC 322). The previous editions of this standard are as follows: —GB/T 14542-1993, GB/T 14542-2005. Guide for maintenance and supervision of transformer oil 1 Scope This standard gives principles for maintenance and supervision of transformer oil. This standard is applicable to mineral insulating oils used in oil-filled electrical equipment such as power transformers, reactors, instrument transformers, and oil-filled bushings. This standard does not apply to synthetic insulating liquids. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 261 Determination of flash point—Pensky-Martens closed cup method GB 264 Petroleum products—Determination of acid number GB/T 507 Insulating liquids—Determination of the breakdown voltage at power frequency GB 2536 Fluids for electrotechnical applications—Unused mineral insulating oils for transformers and switchgear GB/T 5654 Insulating liquids—Measurement of relative permittivity, dielectric dissipation factor (tanδ) and d.c. resistivity GB/T 6540 Petroleum products—Determination of color GB/T 6541 Petroleum products—Mineral oils—Determination of interfacial tension of oil against water—Ring method GB/T 7595 Quality of transformer oils in service GB/T 7597 Method of sampling for transformer and turbine oils in electric power industry GB/T 7598 Determination of water-soluble acid in transformer oils in service GB/T 7600 Determination of water content in transformer oils and turbine oils in service by coulometric method GB/T 8926-2012 Standard test method for insolubles in used lubricating oils GB 50150 Standard for hand-over test of electric equipment electric equipment installation engineering DL/T 285 Determination of corrosive sulfur in mineral insulating oils—Insulated copper flat wire method DL/T 385 Determination of electrification tendency of transformer oil DL/T 419 Power oil terminology DL/T 421 Determination of oil volume resistivity of power oil DL/T 429.6 Open cup aging test for power oils DL/T 429.7 Determination of sludge by precipitation DL/T 432 Determination of particulate contamination in power oils DL/T 596 Preventive test procedures for power equipment DL/T 703 Determination of gas content in insulating oil by gas chromatography DL/T 722 Guideline for the analysis and determination of dissolved gases in transformer oil DL/T 1096 Particle size limit in transformer oil DL/T 1355 Determination of furfural content in transformer oil—Liquid chromatography DL/T 1419 Guideline for reclamation and use of transformer oil DL/T 1459 Determination of the content of metal passivator in mineral insulating oils—High performance liquid chromatography DL/T 1552 Guideline for storage management of transformer oil NB/SH/T 0810 Determination of gassing characteristic of insulating liquid under electric field and ionization effect NB/SH/T 0812 Determination of 2-furfural and related components in mineral insulating oil SH/T 0802 Determination of 2,6-bi-tert-butyl-paracresol in insulating oils IEC 60422 Mineral insulating oils in electrical equipment—Supervision and maintenance guidance IEC 62697-1 Test methods for quantitative determination of corrosive sulfur compounds in unused and used insulating liquids—Part 1: Test method for quantitative determination of dibenzyl disulfide (DBDS) 3 Terms and definitions For the purposes of this document, the terms and definitions given in DL/T 419 and the following apply. 3.1 mineral insulating oil refined insulating oil from natural petroleum [Definition 3.9 in DL/T 419-2015] 3.2 reconditioning process that reduces the content of impurities such as gases, water, and solid particles in used oil products to an acceptable level by physical processing [Definition 8.2 in DL/T 419-2015] 3.3 reclaiming, regeneration process that eliminates harmful chemical components from the oil by chemical and physical processing so as to restore the oil properties as close as possible to its original values [Definition 8.3 in DL/T 419-2015] 4 Sampling Sampling containers and methods are implemented in accordance with GB/T 7597, and containers and methods for measuring particle contamination in oil are implemented in accordance with DL/T 432. 5 Acceptance of new transformer oil 5.1 Acceptance of new oil During the acceptance of new oil, all accepted oil products shall be monitored to prevent errors or introduction of contaminants. New oil shall be accepted in accordance with GB 2536, or may be accepted in accordance with relevant international standards or the contract. 5.2 Inspection of new oil before filling in transformer (reactor) Before filling in equipment, new oil shall be filtered with vacuum filterer to remove water, gases and other particulate impurities from the oil, to the satisfaction of Table 1. Inspection of instrument transformer and bushing oil is performed in accordance with the relevant provision of GB 50150. Table 1 Quality indicators of filtered new oil Item Equipment voltage rating/kV 1 000 750 500 330 220 ≤110 Breakdown voltage/kV ≥75 ≥75 ≥65 ≥55 ≥45 ≥45 Moisture/(mg/L) ≤8 ≤10 ≤10 ≤10 ≤15 ≤20 Dielectric dissipation factor (DDF) (90℃) ≤0.005 Particulate contamination/particle a ≤1 000 ≤1 000 ≤2 000 — — — Note: When necessary, filtered new oil may be inspected for the content of dissolved gas components in the oil according to DL/T 722. a Number of particles larger than 5 μm in 100 mL of oil. 5.3 Inspection of new oil after filling in transformer (reactor) and thermal circulation After filling in transformer (reactor) and thermal circulation, the new oil shall meet the requirements of Table 2. Table 2 Quality indication of the oil after thermal circulation Item Equipment voltage rating/kV 1 000 750 500 330 220 ≤110 Breakdown voltage/kV ≥75 ≥75 ≥65 ≥55 ≥45 ≥45 Moisture/(mg/L) ≤8 ≤10 ≤10 ≤10 ≤15 ≤20 Gas content in oil (by volume)/% ≤0.8 ≤1 ≤1 ≤1 — — Dielectric dissipation factor (90 ℃) ≤0.005 Particulate contamination/particle a ≤1 000 ≤2 000 ≤3 000 — — — a Number of particles larger than 5 μm in 100 mL of oil. 5.4 Inspection before energization for service of new equipment The quality of oil, after filling in a qualified new transformer and thermal circulation but before energization for service, shall meet the requirements under "oil before service" in Table 3. The content of dissolved gas components in oil shall be inspected in accordance with DL/T 722. 6 Inspection of in-service transformer oil 6.1 Quality criteria and inspection frequency of in-service transformer oil 6.1.1 The quality of in-service oil for transformer and circuit breaker shall be inspected in accordance with GB/T 7595, and oils for specific equipment shall be inspected as specified by the manufacturer. The quality criteria of in-service transformer oil are shown in Table 3, and those of in service circuit breaker oil are shown in Table 4.
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Sampling 5 Acceptance of new transformer oil 6 Inspection of in-service transformer oil 7 Oil compatibility (mixed oil) 8 Maintenance of in-service transformer oil 9 Transformer sludge flushing 10 Storage and transportation of oil 11 Technical files and information of equipment 12 Safety and health Annex A (Informative) Measures to prevent transformer oil deterioration Annex B (Informative) Common materials for oil aging prevention and oil processing methods
Referred in GB/T 14542-2017:
*GB/T 261-2021 Determination of flash point—Pensky-Martens closed cup method
*GB 264-1983 Petroleum products;Determination of acid number
*GB/T 507-2002 Insulating liquids--Determination of the breakdown voltage at power frequency
*GB 2536-2011 Fluids for electrotechnical applications—Unused mineral insulating oils for transformers and switchgear
*GB/T 5654-2007 Insulating liquids - Measurement of relative permittivity dielectric dissipation factor(tanδ)and d.c. resistivity
*GB/T 6540-1986 Petroleum products; Determination of colour
*GB/T 6541-1986 Petroleum products; Mineral oils; Determination of interfacial tension of oil against water; Ring method
*GB/T 7595-2017 Quality of transformer oils in service
*GB/T 7597-2007 Method of sampling for transformer and turbine oils in electric power industry
*GB/T 7598-2008 Determination of water-soluble acid in transformer oils in service
*GB/T 7600-2014 Determination of water content in transformer oils and turbine oils in service by coulometric method
*GB/T 8926-2012 Standard test method for insolubles in used lubricating oils
*GB 50150-2016 Standard for hand - over test of electrical equipment for installation of electrical installations
*DL/T 285-2012 Test method for corrosive sulphur in mineral insulating oils. Copper conductor wrapped with insulating paper
*DL/T 385-2010 Determination of electrostatic charging tendency of transformer oil
*DL/T 419-2015 Glossary on Electric Power Oil
*DL/T 421-2009 Determination of volume resistivity of power oils
*DL/T 429.6-2015 Determination of Open Cup Aging of Power Oils
*DL/T 429.7-2017 Determination of sludge for electric power oils
*DL/T 432-2018 Determination of particulate contamination in oil used in power industry
*DL/T 596-2021 Preventive test code for electric power equipment
*DL/T 703-2015 Determination of Dissolved Gas Content in Insulating Oil by Gas Chromatograhy
*DL/T 722-2014 Guide to the Analysis and the Diagnosis of Gases Dissolved in Transformer Oil
*DL/T 1096-2018
*DL/T 1355-2014 Method for Determination of Furfural Content in Transformer Oil by HPLC
*DL/T 1419-2015 Guide for the Reclamation of Transformer Oil and Criteria for Its Use
*DL/T 1459-2015 Quantitative Determination of Metal Passivators In Mineral Insulating Oils(HPLC)
*DL/T 1552-2016 Code for storage and management of transformer oil
*NB/SH/T 0810-2010 Gassing of Insulating Liquids Under Electrical Stress and Ionization
*NB/SH/T 0812-2010 Mineral Insulating Oils - Method for the Determination of 2-Furfural and Related Compounds
*SH/T 0802-2007 Determination of 2 6-bi-tert-butyl-paracresol in insulating oils
GB/T 14542-2017 is referred in:
*GB/T 20042.1-2017 Proton exchange membrane fuel cell -- Part 1: Terminology
*GB/T 246-2017 Metallic materials - Tube - Flattening test
*GB/T 26949.15-2017 Industrial trucks-Verification of stability- Part 15:Counterbalanced trucks with articulated steering
*GB/T 22731-2017 Fragrance compound
*GB/T 15670.6-2017 Toxicological test methods for pesticides registration. Part 6: Acute inhalation toxicity test
Code of China
Standard
GB/T 14542-2017  Guide for maintenance and supervision of transformer oil (English Version)
Standard No.GB/T 14542-2017
Statusvalid
LanguageEnglish
File FormatPDF
Word Count10500 words
Price(USD)260.0
Implemented on2017-12-1
Deliveryvia email in 1 business day
Detail of GB/T 14542-2017
Standard No.
GB/T 14542-2017
English Name
Guide for maintenance and supervision of transformer oil
Chinese Name
变压器油维护管理导则
Chinese Classification
F24
Professional Classification
GB
ICS Classification
Issued by
MOHURD; AQSIQ
Issued on
2017-05-12
Implemented on
2017-12-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 14542-2005 Guide for maintenance and supervision of transformer oil in service
Language
English
File Format
PDF
Word Count
10500 words
Price(USD)
260.0
Keywords
GB/T 14542-2017, GB 14542-2017, GBT 14542-2017, GB/T14542-2017, GB/T 14542, GB/T14542, GB14542-2017, GB 14542, GB14542, GBT14542-2017, GBT 14542, GBT14542
Introduction of GB/T 14542-2017
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB/T 14542-2005 Guide for maintenance and supervision of transformer oil in service, and has the following main technical changes, in addition to editorial changes, made with respect to GB/T 14542-2005: —The standard name has been changed to Guide for maintenance and supervision of transformer oil; —The application scope of the standard has been modified; —The normative references have been modified; —The terms and definitions have been introduced; —The contents in the clause of sampling have been simplified; —The inspection items and quality criteria for oil after new oil purification and hot oil circulation have been modified; —The quality criteria and inspection frequency of in-service transformer oil have been modified, and items including color, gassing, charging tendency, corrosive sulfur, particulate contamination, antioxidant additive content, furfural content and DBDS content have been introduced; —The interpretation of test results has been deleted; —The causes for in-service transformer oil exceeding limits and actions taken have been modified, and limits, possible causes and countermeasures of corrosive sulfur, particulate contamination, furfural content and DBDS content have been introduced; —The oil compatibility (oil mixing) has been modified; —The contents of the clauses regarding anti-aging measures for in-service oil and oil treatment have been consolidated and modified, and the title has been changed to "Maintenance of in-service transformer oil"; —The contents of the clause regarding of oil storage, transportation and technical management have been modified; —The informative Annex A has been deleted. —The contents in Annex B of the original standard have been modified. This standard was prepared using the redrafting method with reference to IEC 60422:2013 Mineral insulating oils in electrical equipment—Supervision and maintenance guidance, and is not equivalent to IEC 60422:2013. This standard was proposed by the China Electricity Council (CEC). This standard is under the jurisdiction of the National Technical Committee on Electrochemistry of Standardization Administration of China (SAC/TC 322). The previous editions of this standard are as follows: —GB/T 14542-1993, GB/T 14542-2005. Guide for maintenance and supervision of transformer oil 1 Scope This standard gives principles for maintenance and supervision of transformer oil. This standard is applicable to mineral insulating oils used in oil-filled electrical equipment such as power transformers, reactors, instrument transformers, and oil-filled bushings. This standard does not apply to synthetic insulating liquids. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 261 Determination of flash point—Pensky-Martens closed cup method GB 264 Petroleum products—Determination of acid number GB/T 507 Insulating liquids—Determination of the breakdown voltage at power frequency GB 2536 Fluids for electrotechnical applications—Unused mineral insulating oils for transformers and switchgear GB/T 5654 Insulating liquids—Measurement of relative permittivity, dielectric dissipation factor (tanδ) and d.c. resistivity GB/T 6540 Petroleum products—Determination of color GB/T 6541 Petroleum products—Mineral oils—Determination of interfacial tension of oil against water—Ring method GB/T 7595 Quality of transformer oils in service GB/T 7597 Method of sampling for transformer and turbine oils in electric power industry GB/T 7598 Determination of water-soluble acid in transformer oils in service GB/T 7600 Determination of water content in transformer oils and turbine oils in service by coulometric method GB/T 8926-2012 Standard test method for insolubles in used lubricating oils GB 50150 Standard for hand-over test of electric equipment electric equipment installation engineering DL/T 285 Determination of corrosive sulfur in mineral insulating oils—Insulated copper flat wire method DL/T 385 Determination of electrification tendency of transformer oil DL/T 419 Power oil terminology DL/T 421 Determination of oil volume resistivity of power oil DL/T 429.6 Open cup aging test for power oils DL/T 429.7 Determination of sludge by precipitation DL/T 432 Determination of particulate contamination in power oils DL/T 596 Preventive test procedures for power equipment DL/T 703 Determination of gas content in insulating oil by gas chromatography DL/T 722 Guideline for the analysis and determination of dissolved gases in transformer oil DL/T 1096 Particle size limit in transformer oil DL/T 1355 Determination of furfural content in transformer oil—Liquid chromatography DL/T 1419 Guideline for reclamation and use of transformer oil DL/T 1459 Determination of the content of metal passivator in mineral insulating oils—High performance liquid chromatography DL/T 1552 Guideline for storage management of transformer oil NB/SH/T 0810 Determination of gassing characteristic of insulating liquid under electric field and ionization effect NB/SH/T 0812 Determination of 2-furfural and related components in mineral insulating oil SH/T 0802 Determination of 2,6-bi-tert-butyl-paracresol in insulating oils IEC 60422 Mineral insulating oils in electrical equipment—Supervision and maintenance guidance IEC 62697-1 Test methods for quantitative determination of corrosive sulfur compounds in unused and used insulating liquids—Part 1: Test method for quantitative determination of dibenzyl disulfide (DBDS) 3 Terms and definitions For the purposes of this document, the terms and definitions given in DL/T 419 and the following apply. 3.1 mineral insulating oil refined insulating oil from natural petroleum [Definition 3.9 in DL/T 419-2015] 3.2 reconditioning process that reduces the content of impurities such as gases, water, and solid particles in used oil products to an acceptable level by physical processing [Definition 8.2 in DL/T 419-2015] 3.3 reclaiming, regeneration process that eliminates harmful chemical components from the oil by chemical and physical processing so as to restore the oil properties as close as possible to its original values [Definition 8.3 in DL/T 419-2015] 4 Sampling Sampling containers and methods are implemented in accordance with GB/T 7597, and containers and methods for measuring particle contamination in oil are implemented in accordance with DL/T 432. 5 Acceptance of new transformer oil 5.1 Acceptance of new oil During the acceptance of new oil, all accepted oil products shall be monitored to prevent errors or introduction of contaminants. New oil shall be accepted in accordance with GB 2536, or may be accepted in accordance with relevant international standards or the contract. 5.2 Inspection of new oil before filling in transformer (reactor) Before filling in equipment, new oil shall be filtered with vacuum filterer to remove water, gases and other particulate impurities from the oil, to the satisfaction of Table 1. Inspection of instrument transformer and bushing oil is performed in accordance with the relevant provision of GB 50150. Table 1 Quality indicators of filtered new oil Item Equipment voltage rating/kV 1 000 750 500 330 220 ≤110 Breakdown voltage/kV ≥75 ≥75 ≥65 ≥55 ≥45 ≥45 Moisture/(mg/L) ≤8 ≤10 ≤10 ≤10 ≤15 ≤20 Dielectric dissipation factor (DDF) (90℃) ≤0.005 Particulate contamination/particle a ≤1 000 ≤1 000 ≤2 000 — — — Note: When necessary, filtered new oil may be inspected for the content of dissolved gas components in the oil according to DL/T 722. a Number of particles larger than 5 μm in 100 mL of oil. 5.3 Inspection of new oil after filling in transformer (reactor) and thermal circulation After filling in transformer (reactor) and thermal circulation, the new oil shall meet the requirements of Table 2. Table 2 Quality indication of the oil after thermal circulation Item Equipment voltage rating/kV 1 000 750 500 330 220 ≤110 Breakdown voltage/kV ≥75 ≥75 ≥65 ≥55 ≥45 ≥45 Moisture/(mg/L) ≤8 ≤10 ≤10 ≤10 ≤15 ≤20 Gas content in oil (by volume)/% ≤0.8 ≤1 ≤1 ≤1 — — Dielectric dissipation factor (90 ℃) ≤0.005 Particulate contamination/particle a ≤1 000 ≤2 000 ≤3 000 — — — a Number of particles larger than 5 μm in 100 mL of oil. 5.4 Inspection before energization for service of new equipment The quality of oil, after filling in a qualified new transformer and thermal circulation but before energization for service, shall meet the requirements under "oil before service" in Table 3. The content of dissolved gas components in oil shall be inspected in accordance with DL/T 722. 6 Inspection of in-service transformer oil 6.1 Quality criteria and inspection frequency of in-service transformer oil 6.1.1 The quality of in-service oil for transformer and circuit breaker shall be inspected in accordance with GB/T 7595, and oils for specific equipment shall be inspected as specified by the manufacturer. The quality criteria of in-service transformer oil are shown in Table 3, and those of in service circuit breaker oil are shown in Table 4.
Contents of GB/T 14542-2017
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Sampling 5 Acceptance of new transformer oil 6 Inspection of in-service transformer oil 7 Oil compatibility (mixed oil) 8 Maintenance of in-service transformer oil 9 Transformer sludge flushing 10 Storage and transportation of oil 11 Technical files and information of equipment 12 Safety and health Annex A (Informative) Measures to prevent transformer oil deterioration Annex B (Informative) Common materials for oil aging prevention and oil processing methods
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 14542-2017, GB 14542-2017, GBT 14542-2017, GB/T14542-2017, GB/T 14542, GB/T14542, GB14542-2017, GB 14542, GB14542, GBT14542-2017, GBT 14542, GBT14542