2025-5-20 18.97.9.174
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 16430-2018
GB/T 16430-2018   Determination of the minimum ignition temperature of dust layer (English Version)
Standard No.: GB/T 16430-2018 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 7500 words Price(USD):220.0 remind me the price change

Email:

Implemented on:2019-7-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 16430-2018
English Name: Determination of the minimum ignition temperature of dust layer
Chinese Name: 粉尘层最低着火温度测定方法
Chinese Classification: C67    Factory fire and blast protection technology
Professional Classification: GB    National Standard
Issued by: SAMR; SAC
Issued on: 2018-12-28
Implemented on: 2019-7-1
Status: valid
Superseding:GB/T 16430-1996 Determination of the minimum ignition temperature of dust layer
Language: English
File Format: PDF
Word Count: 7500 words
Price(USD): 220.0
Delivery: via email in 1 business day
GB/T 16430-2018 Determination of the minimum ignition temperature of dust layer 1 Scope This standard specifies the specimen, test devices, determination procedure and expression of determination results for determination of the minimum ignition temperature of dust layer. This standard is applicable to combustible dust that relies on oxygen in the air to maintain its oxidation reaction. This standard is not applicable to explosives or substances capable of combusting or exploding without relying on oxygen in the air. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 15604 Terminology for dust explosion prevention 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 15604 and the following apply. 3.1 ignition of dust layer state of the test dust layer when flameless or flaming combustion occurs, or when its temperature reaches 450 °C and above, or when its temperature rise reaches or exceeds the hot surface temperature of 250 °C 3.2 minimum ignition temperature of dust layer minimum temperature of the hot surface when a dust layer of specified thickness on the hot surface catches fire Note: Dust exists in a variety of processes, dust layer ignition depends on the actual working conditions, this standard may not represent all process conditions, such as the thickness of the dust layer and ambient temperature distribution and other factors. 3.3 ignition time time from the beginning of the heating of the dust until it reaches its maximum temperature or appears to catch fire 4 Specimen Dust specimen shall be made homogeneous and representative. The dust specimen shall be able to pass through a metal mesh or square orifice plate test sieve with a nominal aperture diameter of 75μm. If it is necessary to test with coarser dust, it is allowed that the dusts pass through a test sieve with a nominal aperture of up to 500μm, and the sieve aperture size shall be specified in the test report. During the preparation of the specimen, any obvious changes in the properties of the dust shall be described in the test report, such as changes caused by sieving or temperature and humidity.
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Specimen 5 Test device 6 Determination procedure 7 Presentation of determination results Annex A (Normative) Structure of hot surface Annex B (Normative) Measurement of temperature distribution on hot surface Annex C (Normative) Inference of minimum ignition temperature of dust layer
Referred in GB/T 16430-2018:
*GB/T 15604-2008 Terminology for dust explosion prevention
Code of China
Standard
GB/T 16430-2018  Determination of the minimum ignition temperature of dust layer (English Version)
Standard No.GB/T 16430-2018
Statusvalid
LanguageEnglish
File FormatPDF
Word Count7500 words
Price(USD)220.0
Implemented on2019-7-1
Deliveryvia email in 1 business day
Detail of GB/T 16430-2018
Standard No.
GB/T 16430-2018
English Name
Determination of the minimum ignition temperature of dust layer
Chinese Name
粉尘层最低着火温度测定方法
Chinese Classification
C67
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2018-12-28
Implemented on
2019-7-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 16430-1996 Determination of the minimum ignition temperature of dust layer
Language
English
File Format
PDF
Word Count
7500 words
Price(USD)
220.0
Keywords
GB/T 16430-2018, GB 16430-2018, GBT 16430-2018, GB/T16430-2018, GB/T 16430, GB/T16430, GB16430-2018, GB 16430, GB16430, GBT16430-2018, GBT 16430, GBT16430
Introduction of GB/T 16430-2018
GB/T 16430-2018 Determination of the minimum ignition temperature of dust layer 1 Scope This standard specifies the specimen, test devices, determination procedure and expression of determination results for determination of the minimum ignition temperature of dust layer. This standard is applicable to combustible dust that relies on oxygen in the air to maintain its oxidation reaction. This standard is not applicable to explosives or substances capable of combusting or exploding without relying on oxygen in the air. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 15604 Terminology for dust explosion prevention 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 15604 and the following apply. 3.1 ignition of dust layer state of the test dust layer when flameless or flaming combustion occurs, or when its temperature reaches 450 °C and above, or when its temperature rise reaches or exceeds the hot surface temperature of 250 °C 3.2 minimum ignition temperature of dust layer minimum temperature of the hot surface when a dust layer of specified thickness on the hot surface catches fire Note: Dust exists in a variety of processes, dust layer ignition depends on the actual working conditions, this standard may not represent all process conditions, such as the thickness of the dust layer and ambient temperature distribution and other factors. 3.3 ignition time time from the beginning of the heating of the dust until it reaches its maximum temperature or appears to catch fire 4 Specimen Dust specimen shall be made homogeneous and representative. The dust specimen shall be able to pass through a metal mesh or square orifice plate test sieve with a nominal aperture diameter of 75μm. If it is necessary to test with coarser dust, it is allowed that the dusts pass through a test sieve with a nominal aperture of up to 500μm, and the sieve aperture size shall be specified in the test report. During the preparation of the specimen, any obvious changes in the properties of the dust shall be described in the test report, such as changes caused by sieving or temperature and humidity.
Contents of GB/T 16430-2018
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Specimen 5 Test device 6 Determination procedure 7 Presentation of determination results Annex A (Normative) Structure of hot surface Annex B (Normative) Measurement of temperature distribution on hot surface Annex C (Normative) Inference of minimum ignition temperature of dust layer