2025-6-24 18.97.9.174
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 16803-1997
GB/T 16803-1997   Equipment of heating, ventilating, air conditioning and air cleaning terminology (English Version)
Standard No.: GB/T 16803-1997 Status:superseded remind me the status change

Email:

Language:English File Format:PDF
Word Count: 12000 words Price(USD):300.0 remind me the price change

Email:

Implemented on:1997-12-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 16803-1997
English Name: Equipment of heating, ventilating, air conditioning and air cleaning terminology
Chinese Name: 采暖、通风、空调、净化设备 术语
Chinese Classification: P45    Heat supply, air supply, air conditioning and refrigerating engineering in general
Professional Classification: GB    National Standard
ICS Classification: 91.140.01 91.140.01    Installations in buildings in general 91.140.01
Issued by: AQSIQ
Issued on: 1997-5-28
Implemented on: 1997-12-1
Status: superseded
Superseded by:GB/T 16803-2018 Equipment of heating,ventilating,air conditioning and air cleaning terminology
Superseded on:2019-4-1
Abolished on:2019-04-01
Language: English
File Format: PDF
Word Count: 12000 words
Price(USD): 300.0
Delivery: via email in 1 business day
1 Scope This standard specifies the generic terms for construction and performance of heating, ventilating, air conditioning and air cleaning equipment. This standard is applicable to the design and production of heating, ventilating, air conditioning and air cleaning equipment without cold source and heat source, and also applicable to research, teaching and publishing work of heating, ventilating, air conditioning and air cleaning equipment. 2 Heating Equipment 2.1 Generic terms 2.1.1 Standard heating capacity of radiator Heating capacity of radiator when the heating medium is hot water, the water inlet temperature of radiator is 90℃, and the difference of average water temperature of inlet and outlet and indoor air temperature is 60℃. 2.1.2 Heat emission per unit weight of radiator Heat emission per unit weight of metal of radiator under each degree of heat transfer temperature difference. Synonym: metal heat intensity of radiator. 2.1.3 Working pressure of radiator Maximum allowable pressure when the radiator operates. 2.1.4 Rated heating capacity of unit heater Heat quantity to supply air by unit heater under rated condition. 2.1.5 Rated air flow rate of unit heater Volume flow of air at outlet section per unit time under normal temperature at rated rotating speed of unit heater. 2.2 Radiator Equipment which heats room or space in convection and radiation mode. 2.2.1 Convector Radiator which mainly adopts convection heat emission mode. 2.2.2 Radiator Radiator which mainly adopts radiation heat emission mode. 2.2.3 Electric radiator Radiator made of electric heating element. The heat may be indirectly released or directly supplied through working medium (e.g. oil). 2.2.4 Gas-fired infrared radiator Radiator which uses combustible gas to combust in a radiator and releases radiant heat in infrared ray form. 2.2.5 Metal radiant panel Radiator which takes high-temperature hot water or high-pressure steam as the heating medium and takes metal panel as the main body, and mainly adopts radiant heat transfer. 2.2.6 Wing type radiator Radiator which has a lot of wings outside the tube, including column wing type, long wing type, circular wing type, square wing type, etc. 2.2.7 Column radiator Radiator composed of cooling fins with hollow column. 2.2.8 Panel radiator Radiator which is welded through metal panel pressing. 2.2.9 Flat tube radiator Radiator which is welded with flat tube and cooling fin. 2.2.10 Finned tube radiator Radiator which is connected in series with metal tube and piece. 2.2.11 Tubular radiator Radiator which is welded with several metal tubes as a grid type. 2.3 Unit heater Warm air heating equipment which is jointly composed of ventilator, air heater, air outlet, etc. It may be divided into steam, hot water, dual steam and hot water due to different heat media. 2.3.1 Unit heater with axial fan Unit heater which is equipped with axial fan. 2.3.2 Unit heater with centrifugal fan Unit heater which is equipped with centrifugal fan. 2.3.3 Circular top blow unit heater Unit heater which blows downward after the air is heated. 2.4 Heating part Part matching heating equipment and system. 2.4.1 Expansion tank Vessel which has adjusting compensation and constant pressure function for water volume expansion and contraction in hot water heating system, including open and closed type. 2.4.2 Manual vent Device which is installed on a radiator for manually eliminating air. 2.4.3 Automatic vent Device which is installed on pipeline or radiator for automatically eliminating air. 2.4.4 Thermostatic valve of radiator Valve which is installed on the radiator branch for automatically regulating the heating medium flow along with room temperature change. 2.4.5 Air collector Device which is used for collecting and eliminating air in hot water heating system. 2.4.6 Steam trap Device which is used for eliminating condensed water in steam heating system and preventing steam passing. 2.4.7 Strainer Device which is used for detaining sewage in hot water heating system. 3 Ventilating Equipment 3.1 Generic terms 3.1.1 Rated condition Working condition (parameter) which is specified in the standard for calibrating the capacity of ventilating and air conditioning equipment. 3.1.2 Rated air flow rate Air volume flow sucked or exhausted by equipment in unit time under rated condition. Synonym: nominal air flow rate. 3.1.3 Rated air pressure Total pressure of equipment at rated air flow rate. 3.1.4 Rated rotating speed Revolution number of equipment rotor in unit time under rated condition. 3.1.5 Outlet air velocity Average air velocity at equipment air outlet. 3.1.6 Total pressure loss Total pressure loss when air flows through equipment.
Foreword I 1 Scope 2 Heating Equipment 3 Ventilating Equipment 4 Air Conditioning Equipment 5 Air Cleaning Equipment
GB/T 16803-1997 is referred in:
* GB 19210-2003 Cleaning code for air duct system in heating, ventilating and air-
* GB/T 14294-2008 Central-station Air Handling Units
* GB/T 19232-2003 Fan-coil Unit
* GB/T 14294-2008 Central-station Air Handling Units
* GB/T 19232-2003 Fan-coil Unit
* GB 19210-2003 Cleaning code for air duct system in heating, ventilating and air-
* GB/T 21087-2007 Air-to-Air Energy Recovery Equipment
* GB/T 19232-2003 Fan-coil Unit
* GB/T 6167-2007 Methods for testing the performance of airborne particle counter
*WS 233-2002 General biosafety standard for microbiological and biomedical laboratories
Code of China
Standard
GB/T 16803-1997  Equipment of heating, ventilating, air conditioning and air cleaning terminology (English Version)
Standard No.GB/T 16803-1997
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count12000 words
Price(USD)300.0
Implemented on1997-12-1
Deliveryvia email in 1 business day
Detail of GB/T 16803-1997
Standard No.
GB/T 16803-1997
English Name
Equipment of heating, ventilating, air conditioning and air cleaning terminology
Chinese Name
采暖、通风、空调、净化设备 术语
Chinese Classification
P45
Professional Classification
GB
ICS Classification
Issued by
AQSIQ
Issued on
1997-5-28
Implemented on
1997-12-1
Status
superseded
Superseded by
GB/T 16803-2018 Equipment of heating,ventilating,air conditioning and air cleaning terminology
Superseded on
2019-4-1
Abolished on
2019-04-01
Superseding
Language
English
File Format
PDF
Word Count
12000 words
Price(USD)
300.0
Keywords
GB/T 16803-1997, GB 16803-1997, GBT 16803-1997, GB/T16803-1997, GB/T 16803, GB/T16803, GB16803-1997, GB 16803, GB16803, GBT16803-1997, GBT 16803, GBT16803
Introduction of GB/T 16803-1997
1 Scope This standard specifies the generic terms for construction and performance of heating, ventilating, air conditioning and air cleaning equipment. This standard is applicable to the design and production of heating, ventilating, air conditioning and air cleaning equipment without cold source and heat source, and also applicable to research, teaching and publishing work of heating, ventilating, air conditioning and air cleaning equipment. 2 Heating Equipment 2.1 Generic terms 2.1.1 Standard heating capacity of radiator Heating capacity of radiator when the heating medium is hot water, the water inlet temperature of radiator is 90℃, and the difference of average water temperature of inlet and outlet and indoor air temperature is 60℃. 2.1.2 Heat emission per unit weight of radiator Heat emission per unit weight of metal of radiator under each degree of heat transfer temperature difference. Synonym: metal heat intensity of radiator. 2.1.3 Working pressure of radiator Maximum allowable pressure when the radiator operates. 2.1.4 Rated heating capacity of unit heater Heat quantity to supply air by unit heater under rated condition. 2.1.5 Rated air flow rate of unit heater Volume flow of air at outlet section per unit time under normal temperature at rated rotating speed of unit heater. 2.2 Radiator Equipment which heats room or space in convection and radiation mode. 2.2.1 Convector Radiator which mainly adopts convection heat emission mode. 2.2.2 Radiator Radiator which mainly adopts radiation heat emission mode. 2.2.3 Electric radiator Radiator made of electric heating element. The heat may be indirectly released or directly supplied through working medium (e.g. oil). 2.2.4 Gas-fired infrared radiator Radiator which uses combustible gas to combust in a radiator and releases radiant heat in infrared ray form. 2.2.5 Metal radiant panel Radiator which takes high-temperature hot water or high-pressure steam as the heating medium and takes metal panel as the main body, and mainly adopts radiant heat transfer. 2.2.6 Wing type radiator Radiator which has a lot of wings outside the tube, including column wing type, long wing type, circular wing type, square wing type, etc. 2.2.7 Column radiator Radiator composed of cooling fins with hollow column. 2.2.8 Panel radiator Radiator which is welded through metal panel pressing. 2.2.9 Flat tube radiator Radiator which is welded with flat tube and cooling fin. 2.2.10 Finned tube radiator Radiator which is connected in series with metal tube and piece. 2.2.11 Tubular radiator Radiator which is welded with several metal tubes as a grid type. 2.3 Unit heater Warm air heating equipment which is jointly composed of ventilator, air heater, air outlet, etc. It may be divided into steam, hot water, dual steam and hot water due to different heat media. 2.3.1 Unit heater with axial fan Unit heater which is equipped with axial fan. 2.3.2 Unit heater with centrifugal fan Unit heater which is equipped with centrifugal fan. 2.3.3 Circular top blow unit heater Unit heater which blows downward after the air is heated. 2.4 Heating part Part matching heating equipment and system. 2.4.1 Expansion tank Vessel which has adjusting compensation and constant pressure function for water volume expansion and contraction in hot water heating system, including open and closed type. 2.4.2 Manual vent Device which is installed on a radiator for manually eliminating air. 2.4.3 Automatic vent Device which is installed on pipeline or radiator for automatically eliminating air. 2.4.4 Thermostatic valve of radiator Valve which is installed on the radiator branch for automatically regulating the heating medium flow along with room temperature change. 2.4.5 Air collector Device which is used for collecting and eliminating air in hot water heating system. 2.4.6 Steam trap Device which is used for eliminating condensed water in steam heating system and preventing steam passing. 2.4.7 Strainer Device which is used for detaining sewage in hot water heating system. 3 Ventilating Equipment 3.1 Generic terms 3.1.1 Rated condition Working condition (parameter) which is specified in the standard for calibrating the capacity of ventilating and air conditioning equipment. 3.1.2 Rated air flow rate Air volume flow sucked or exhausted by equipment in unit time under rated condition. Synonym: nominal air flow rate. 3.1.3 Rated air pressure Total pressure of equipment at rated air flow rate. 3.1.4 Rated rotating speed Revolution number of equipment rotor in unit time under rated condition. 3.1.5 Outlet air velocity Average air velocity at equipment air outlet. 3.1.6 Total pressure loss Total pressure loss when air flows through equipment.
Contents of GB/T 16803-1997
Foreword I 1 Scope 2 Heating Equipment 3 Ventilating Equipment 4 Air Conditioning Equipment 5 Air Cleaning Equipment
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 16803-1997, GB 16803-1997, GBT 16803-1997, GB/T16803-1997, GB/T 16803, GB/T16803, GB16803-1997, GB 16803, GB16803, GBT16803-1997, GBT 16803, GBT16803