GB/T 17215.322-2008   Electricity metering equipment (a.c.) - Particular requirements - Part 22: Static meters for active energy (classes 0 2 S and 0 5 S) (English Version)
Standard No.: GB/T 17215.322-2008 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5000 words Translation Price(USD):120.0 remind me the price change

Email:

Implemented on:2009-1-1 Delivery: via email in 1 business day

→ → →

2021-11-01,2021-11-1,2009-1-1,14113818185484CC0E6769A12E7CB
Standard No.: GB/T 17215.322-2008
English Name: Electricity metering equipment (a.c.) - Particular requirements - Part 22: Static meters for active energy (classes 0 2 S and 0 5 S)
Chinese Name: 交流电测量设备 特殊要求 第22部分:静止式有功电能表(0.2S级和0.5S级)
Chinese Classification: N22    Electric energy measurement and load control system
Professional Classification: GB    National Standard
ICS Classification: 17.220.20 17.220.20    Measurement of electrical and magnetic quantities 17.220.20
Source Content Issued by: AQSIQ; SAC
Issued on: 2008-06-30
Implemented on: 2009-1-1
Status: superseded
Superseded by:GB/T 17215.321-2021 Electricity metering equipment (AC)-Particular requirements-Part 21:Static meters for active energy
Superseded on:2021-11-1
Abolished on:2021-11-01
Superseding:GB/T 17883-1999 Alternating current static watt-hour meters for active energy (classes 0.2S and 0.5S)
Target Language: English
File Format: PDF
Word Count: 5000 words
Translation Price(USD): 120.0
Delivery: via email in 1 business day
1 Scope This part of GB/T 17215 is only applicable to newly manufactured static meters for active energy of accuracy classes 0.2S and 0.5S, for the measurement of alternating current electrical active energy in 50Hz or 60Hz networks and it is only applicable to their type tests. This Part is applicable to transformer-operated static electric energy meters for indoor application consisting of a measuring element and register(s) enclosed together in a meter case. It is also applicable to operation indicator(s) and test output(s). If the meter has a measuring element for more than one type of energy (multi-energy meters), or when other functional elements, like maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, data communication interfaces, etc. are enclosed in the same meter case, then the relevant standards for these elements also apply. Note: GB/T 1208.1-2006 specifies transformers having a measuring range of 0.01In to 1.2In, or of 0.05In to 1.5In, or of 0.05In to 2In and transformers having a measuring range of 0.01In to 1.2In for accuracy classes 0.2S and 0.5S. As the measuring ranges of a meter and its associated transformers must be matched and as only transformers of classes 0.2S and 0.5S have the accuracy required to operate the meters of this standard, the measuring range of the meter shall be 0.01In to 1.2In. This Part is not applicable to: a) active energy meters where the voltage across the connection terminals exceeds 600 V (line-to-line voltage for meters for polyphase systems); b) portable meters and meters for outdoor use; c) data interfaces to the register of the meter; d) reference meters. Note: The dependability aspect is covered by the documents of the IEC 62059 series. 2 Normative References The following documents contain provisions which, through reference in this Part of GB/T 17215, constitute provisions of this Part. For dated references, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties whose enter into agreement according to this Part are encouraged to research whether the latest editions of these documents are applied or not. For undated references, the latest edition of the normative document is applicable to this part. GB/T 1208.1—2006 Instrument Transformers – Part 1: Current Transformers (IEC 60044-1: 1996, IDT) GB/T 11150—2001 Testing Equipment for Electrical Energy Meters (neq IEC 60736: 1982) GB/T 17215.211—2006 Electricity Metering Equipment (a.c.) – General Requirements, Tests and Test Conditions – Part 11: Metering Equipment (IEC 62052-11 2003,IDT); IEC 62053-61:1998 Electricity Metering Equipment (a.c.) - Particular Requirements - Part 61: Power Consumption and Voltage Requirements 3 Terms and Definitions For the purposes of this Part, the terms and definitions given in GB/T 17215.211-2006 apply. 4 Standard Electrical Values For the purposes of this Part, the electrical values given in GB/T 17215.211-2006 apply. 5 Mechanical Requirements For the purposes of this Part, the requirements of GB/T 17215.211-2006 apply. 6 Climatic Conditions For the purposes of this Part, the conditions specified in GB/T 17215.211-2006 apply.
Foreword I Introduction II 1 Scope 2 Normative References 3 Terms and Definitions 4 Standard Electrical Values 5 Mechanical Requirements 6 Climatic Conditions 7 Electrical Requirements 7.1 Power Consumption 7.2 Influence of Short-time Overcurrents 7.3 Influence of Self-heating 7.4 AC Voltage Test 8 Accuracy Requirements 8.1 Limits of Error Due to Variation of the Current 8.2 Limits of Error Due to Other Influence Quantities 8.3 Test of Starting and No-load Condition 8.4 Meter Constant 8.5 Accuracy Test Conditions 8.6 Interpretation of Test Results Appendix A (Normative) Test Circuit Diagram for Sub-harmonics Appendix B (Normative) Electromagnet for Testing the Influence of Externally Produced Magnetic Fields Figure A.1 Test Circuit Diagram Figure A.2 Burst Fired Wave-form Figure A.3 Distribution of Harmonics (the Fourier analysis is not complete) Table 1 Power Consumption (Including the Power Supply) Table 2 Variation Due to Self-heating Table 3 AC Voltage Test Table 4 Percentage Error Limits (Single-phase Meters and Polyphase Meters with Balanced Loads) Table 5 Percent Error Limits (Polyphase Meters Carrying a Single-phase Load, but with Balanced Polyphase Voltages Applied to Voltage Circuits) Table 6 Influence Quantities Table 7 Voltage and Current Balance Table 8 Reference Conditions Table 9 Interpretation of Test Results
Referred in GB/T 17215.322-2008:
*-
*GB/T 11150-2001 equipment for electrical energy meters
*GB/T 17215.211-2006 GB/T 17215.211-2006
GB/T 17215.322-2008 is referred in:
*GB/T 29319-2012 Technical requirements for connecting photovoltaic power system to distribution network
*GB/T 17215.304-2017 Electricity metering equipment(a.c.)-Particular requirements- Part 4:Static meters connected via electronic transformer
Code of China
Standard
GB/T 17215.322-2008  Electricity metering equipment (a.c.) - Particular requirements - Part 22: Static meters for active energy (classes 0 2 S and 0 5 S) (English Version)
Standard No.GB/T 17215.322-2008
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count5000 words
Price(USD)120.0
Implemented on2009-1-1
Deliveryvia email in 1 business day
Detail of GB/T 17215.322-2008
Standard No.
GB/T 17215.322-2008
English Name
Electricity metering equipment (a.c.) - Particular requirements - Part 22: Static meters for active energy (classes 0 2 S and 0 5 S)
Chinese Name
交流电测量设备 特殊要求 第22部分:静止式有功电能表(0.2S级和0.5S级)
Chinese Classification
N22
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2008-06-30
Implemented on
2009-1-1
Status
superseded
Superseded by
GB/T 17215.321-2021 Electricity metering equipment (AC)-Particular requirements-Part 21:Static meters for active energy
Superseded on
2021-11-1
Abolished on
2021-11-01
Superseding
GB/T 17883-1999 Alternating current static watt-hour meters for active energy (classes 0.2S and 0.5S)
Language
English
File Format
PDF
Word Count
5000 words
Price(USD)
120.0
Keywords
GB/T 17215.322-2008, GB 17215.322-2008, GBT 17215.322-2008, GB/T17215.322-2008, GB/T 17215.322, GB/T17215.322, GB17215.322-2008, GB 17215.322, GB17215.322, GBT17215.322-2008, GBT 17215.322, GBT17215.322
Introduction of GB/T 17215.322-2008
1 Scope This part of GB/T 17215 is only applicable to newly manufactured static meters for active energy of accuracy classes 0.2S and 0.5S, for the measurement of alternating current electrical active energy in 50Hz or 60Hz networks and it is only applicable to their type tests. This Part is applicable to transformer-operated static electric energy meters for indoor application consisting of a measuring element and register(s) enclosed together in a meter case. It is also applicable to operation indicator(s) and test output(s). If the meter has a measuring element for more than one type of energy (multi-energy meters), or when other functional elements, like maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, data communication interfaces, etc. are enclosed in the same meter case, then the relevant standards for these elements also apply. Note: GB/T 1208.1-2006 specifies transformers having a measuring range of 0.01In to 1.2In, or of 0.05In to 1.5In, or of 0.05In to 2In and transformers having a measuring range of 0.01In to 1.2In for accuracy classes 0.2S and 0.5S. As the measuring ranges of a meter and its associated transformers must be matched and as only transformers of classes 0.2S and 0.5S have the accuracy required to operate the meters of this standard, the measuring range of the meter shall be 0.01In to 1.2In. This Part is not applicable to: a) active energy meters where the voltage across the connection terminals exceeds 600 V (line-to-line voltage for meters for polyphase systems); b) portable meters and meters for outdoor use; c) data interfaces to the register of the meter; d) reference meters. Note: The dependability aspect is covered by the documents of the IEC 62059 series. 2 Normative References The following documents contain provisions which, through reference in this Part of GB/T 17215, constitute provisions of this Part. For dated references, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties whose enter into agreement according to this Part are encouraged to research whether the latest editions of these documents are applied or not. For undated references, the latest edition of the normative document is applicable to this part. GB/T 1208.1—2006 Instrument Transformers – Part 1: Current Transformers (IEC 60044-1: 1996, IDT) GB/T 11150—2001 Testing Equipment for Electrical Energy Meters (neq IEC 60736: 1982) GB/T 17215.211—2006 Electricity Metering Equipment (a.c.) – General Requirements, Tests and Test Conditions – Part 11: Metering Equipment (IEC 62052-11 2003,IDT); IEC 62053-61:1998 Electricity Metering Equipment (a.c.) - Particular Requirements - Part 61: Power Consumption and Voltage Requirements 3 Terms and Definitions For the purposes of this Part, the terms and definitions given in GB/T 17215.211-2006 apply. 4 Standard Electrical Values For the purposes of this Part, the electrical values given in GB/T 17215.211-2006 apply. 5 Mechanical Requirements For the purposes of this Part, the requirements of GB/T 17215.211-2006 apply. 6 Climatic Conditions For the purposes of this Part, the conditions specified in GB/T 17215.211-2006 apply.
Contents of GB/T 17215.322-2008
Foreword I Introduction II 1 Scope 2 Normative References 3 Terms and Definitions 4 Standard Electrical Values 5 Mechanical Requirements 6 Climatic Conditions 7 Electrical Requirements 7.1 Power Consumption 7.2 Influence of Short-time Overcurrents 7.3 Influence of Self-heating 7.4 AC Voltage Test 8 Accuracy Requirements 8.1 Limits of Error Due to Variation of the Current 8.2 Limits of Error Due to Other Influence Quantities 8.3 Test of Starting and No-load Condition 8.4 Meter Constant 8.5 Accuracy Test Conditions 8.6 Interpretation of Test Results Appendix A (Normative) Test Circuit Diagram for Sub-harmonics Appendix B (Normative) Electromagnet for Testing the Influence of Externally Produced Magnetic Fields Figure A.1 Test Circuit Diagram Figure A.2 Burst Fired Wave-form Figure A.3 Distribution of Harmonics (the Fourier analysis is not complete) Table 1 Power Consumption (Including the Power Supply) Table 2 Variation Due to Self-heating Table 3 AC Voltage Test Table 4 Percentage Error Limits (Single-phase Meters and Polyphase Meters with Balanced Loads) Table 5 Percent Error Limits (Polyphase Meters Carrying a Single-phase Load, but with Balanced Polyphase Voltages Applied to Voltage Circuits) Table 6 Influence Quantities Table 7 Voltage and Current Balance Table 8 Reference Conditions Table 9 Interpretation of Test Results
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 17215.322-2008, GB 17215.322-2008, GBT 17215.322-2008, GB/T17215.322-2008, GB/T 17215.322, GB/T17215.322, GB17215.322-2008, GB 17215.322, GB17215.322, GBT17215.322-2008, GBT 17215.322, GBT17215.322