2025-12-10 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 18114.10-2010
GB/T 18114.10-2010   Chemical analysis methods of rare earth concentrates—Part 10:Determination of water content—Gravimetry (English Version)
Standard No.: GB/T 18114.10-2010 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 4000 words Translation Price(USD):100.0 remind me the price change

Email:

Implemented on:2011-11-1 Delivery: via email in 1 business day

→ → →

,,2011-11-1,14113818189013DD79CEE0C0B0FA1
Standard No.: GB/T 18114.10-2010
English Name: Chemical analysis methods of rare earth concentrates—Part 10:Determination of water content—Gravimetry
Chinese Name: 稀土精矿化学分析方法 第10部分:水分的测定 重量法
Chinese Classification: H14    Rare metals and their alloys analysis method
Professional Classification: GB    National Standard
ICS Classification: 77.120.99 77.120.99    Other non-ferrous metals and their alloys 77.120.99
Source Content Issued by: AQSIQ;SAC
Issued on: 2011-1-14
Implemented on: 2011-11-1
Status: valid
Superseding:GB/T 18114.10-2000 Methods for chemical analysis of monazite concentrates-Determination of water content
Target Language: English
File Format: PDF
Word Count: 4000 words
Translation Price(USD): 100.0
Delivery: via email in 1 business day
GB/T 18114.10-2010 Chemical analysis methods of rare earth concentrates - Part 10: Determination of water content - Gravimetry 1 Scope This part of GB/T 18114 specifies the determination methods of water content in rare earth concentrates. This part is applicable to the determination of water content in rare earth concentrates, with a determination range of 0.02–20.00%. 2 Principle Weigh a certain quantity of rare earth concentrate test portion, dry it at 105–110°C for a specified period. Then measure the mass loss and calculate the water content. 3 Instruments and reagents 3.1 Oven: Capable of maintaining temperatures above 110°C. 3.2 Weighing bottle. 3.3 Balance: With a sensitivity of 0.0001 g. 4 Specimen The rare earth concentrate specimen shall be stored in a sealed container. 5 Analytical procedures
Foreword i 1 Scope 2 Principle 3 Instruments and reagents 4 Specimen 5 Analytical procedures 6 Calculation and expression of analysis results 7 Precision 8 Quality assurance and control
Code of China
Standard
GB/T 18114.10-2010  Chemical analysis methods of rare earth concentrates—Part 10:Determination of water content—Gravimetry (English Version)
Standard No.GB/T 18114.10-2010
Statusvalid
LanguageEnglish
File FormatPDF
Word Count4000 words
Price(USD)100.0
Implemented on2011-11-1
Deliveryvia email in 1 business day
Detail of GB/T 18114.10-2010
Standard No.
GB/T 18114.10-2010
English Name
Chemical analysis methods of rare earth concentrates—Part 10:Determination of water content—Gravimetry
Chinese Name
稀土精矿化学分析方法 第10部分:水分的测定 重量法
Chinese Classification
H14
Professional Classification
GB
ICS Classification
Issued by
AQSIQ;SAC
Issued on
2011-1-14
Implemented on
2011-11-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 18114.10-2000 Methods for chemical analysis of monazite concentrates-Determination of water content
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
100.0
Keywords
GB/T 18114.10-2010, GB 18114.10-2010, GBT 18114.10-2010, GB/T18114.10-2010, GB/T 18114.10, GB/T18114.10, GB18114.10-2010, GB 18114.10, GB18114.10, GBT18114.10-2010, GBT 18114.10, GBT18114.10
Introduction of GB/T 18114.10-2010
GB/T 18114.10-2010 Chemical analysis methods of rare earth concentrates - Part 10: Determination of water content - Gravimetry 1 Scope This part of GB/T 18114 specifies the determination methods of water content in rare earth concentrates. This part is applicable to the determination of water content in rare earth concentrates, with a determination range of 0.02–20.00%. 2 Principle Weigh a certain quantity of rare earth concentrate test portion, dry it at 105–110°C for a specified period. Then measure the mass loss and calculate the water content. 3 Instruments and reagents 3.1 Oven: Capable of maintaining temperatures above 110°C. 3.2 Weighing bottle. 3.3 Balance: With a sensitivity of 0.0001 g. 4 Specimen The rare earth concentrate specimen shall be stored in a sealed container. 5 Analytical procedures
Contents of GB/T 18114.10-2010
Foreword i 1 Scope 2 Principle 3 Instruments and reagents 4 Specimen 5 Analytical procedures 6 Calculation and expression of analysis results 7 Precision 8 Quality assurance and control
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 18114.10-2010, GB 18114.10-2010, GBT 18114.10-2010, GB/T18114.10-2010, GB/T 18114.10, GB/T18114.10, GB18114.10-2010, GB 18114.10, GB18114.10, GBT18114.10-2010, GBT 18114.10, GBT18114.10