GB/T 18204.1-2025   Examination methods for public places—Part 1: Physical indicators (English Version)
Standard No.: GB/T 18204.1-2025 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 16500 words Translation Price(USD):495.0 remind me the price change

Email:

Implemented on:2025-12-1 Delivery: via email in 1~3 business day

→ → →

,,2025-12-1,9B2F6D966174C1881749469384003
Standard No.: GB/T 18204.1-2025
English Name: Examination methods for public places—Part 1: Physical indicators
Chinese Name: 公共场所卫生检验方法 第1部分:物理性指标
Chinese Classification: C51    Environmental sanitation
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2025-05-30
Implemented on: 2025-12-1
Status: valid
Superseding:GB/T 18204.1-2013 Examination methods for public places - Part 1: Physical parameters
Target Language: English
File Format: PDF
Word Count: 16500 words
Translation Price(USD): 495.0
Delivery: via email in 1~3 business day
GB/T 18204.1-2025 Examination methods for public places – Part 1: Physical indicators 1 Scope This document describes the methods for measuring physical indicators in public places. This document is applicable to the measurement of physical indicators in public places. Other places, such as residential rooms and other indoor environments, should refer to this document for guidance. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 18049 Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria GB/T 18883 Standards for indoor air quality HJ/T 10.2 Guideline on management of radioactive environmental protection - Electromagnetic radiation monitoring instruments and methods HJ 1212 Measurement methods for determination of radon in environmental air JGJ/T 309 The standard of the measurement and evaluation for efficiency of building ventilation ISO 7726 Ergonomics of the thermal environment - Instruments for measuring physical quantities ISO/TS 14415:2005 Ergonomics of the thermal environment - Application of International Standards to people with special requirements 3 Terms and definitions No terms and definitions are listed in this document. 4 Air temperature 4.1 Liquid-in-glass thermometer method 4.1.1 Principle The liquid-in-glass thermometer is composed of a thin-walled temperature sensing bulb containing the thermometer liquid and a thin glass tube sealed and connected with the temperature sensing bulb. The change of air temperature will cause the temperature change of the temperature sensing bulb, and the liquid volume in the temperature sensing bulb will change accordingly. When the temperature of the temperature sensing bulb increases, the liquid expands and the liquid column in the thin tube rises; and vice versa. The thin glass tube is graduated to indicate the height of the liquid column inside the tube, and the liquid column height reading accurately indicates the temperature of the temperature sensing bulb. 4.1.2 Instruments The instruments used in this method are as follows: ——Liquid-in-glass thermometer (minimum scale division not exceeding 0.2°C, measurement accuracy ±0.5°C); ——Thermometer hanging bracket. 4.1.3 Measurement procedures Measurement procedures shall be carried out as follows: a) The layout of measuring points shall comply with the provisions of A.2, Annex A; b) Readings shall be taken after 5 minutes. When taking readings, first read the decimal part and then the integer. The line of sight shall be perpendicular to the thermometer scale. For mercury thermometers, readings shall be taken at the highest point of the convex surface; for alcohol thermometers, readings shall be taken at the lowest point of the concave surface. c) Readings shall be taken quickly and accurately to avoid the influence of human breath on the accuracy of the readings; d) Due to the thermal after-effect of glass, the zero point position of the liquid-in-glass thermometer shall be frequently calibrated with a standard thermometer. If there is a displacement at the zero point, the displacement value shall be added to the reading; e) When exposed to sunlight or other thermal radiation, the temperature sensing bulb shall be shielded from heat when necessary to prevent contact with body parts such as hands. 4.1.4 Result calculation Temperatures shall be calculated using Equations (1) and (2). tactual = tmeasured + d (1) where, tactual——the actual temperature, °C. tmeasured——the measured temperature, °C. d——the zero displacement value, °C. d = a - b (2) where, a——the zero point shown by thermometer; b——the zero point position of standard thermometer calibration. 4.1.5 Result expression The measurement result of an area is given as the arithmetic mean of the measured values of the measuring points in the area. 4.1.6 Measuring range Air temperature: -0°C ~ 50°C. 4.2 Digital display thermometer 4.2.1 Principle PN junction thermistor, thermocouple, platinum resistor, etc. are used as the temperature sensor of the thermometer. The sensors generate electrical signals in response to temperature changes, which are then amplified and converted by an A/D converter before being directly displayed by the display as air temperature. 4.2.2 Instrument Digital display thermometer: minimum resolution of 0.1°C, measurement accuracy of ±0.5°C. 4.2.3 Measurement procedures The measurement procedures shall be carried out as follows: a) Perform in-service verification and pre-use calibration of the instrument as required; b) The arrangement of measuring points is in accordance with the provisions of A.2; c) Operate the instrument in accordance with the instrument manual; d) Read the temperature value after the reading on the display stabilizes. 4.2.4 Measuring range Air temperature: 0°C ~ 50°C; 5 Relative humidity 5.1 Resistance capacitance method 5.1.1 Principle Humidity is measured by utilizing the characteristic of moisture-sensitive elements, whose resistance and capacitance values change according to a certain pattern in response to changes in environmental humidity. 5.1.2 Instruments Various hygrometers using resistive or capacitive humidity sensors (at 25°C, the maximum allowable error is not greater than ±5%). 5.1.3 Measurement procedures The measurement procedures shall be carried out as follows: a) The arrangement of measuring points is in accordance with the provisions of A.2; b) The instrument is operated according to the instruction manual, and the relative humidity value is directly read out after the indicated value of the instrument is stable; c) The humidity-sensitive part of the humidity sensor of the instrument shall not be touched by hands, and shall be protected from dust pollution, harmful gas corrosion or condensation. 5.1.4 Measuring range Under conditions of 0°C ~ 60°C, the measurement range of a resistive hygrometer is 10% to 90%, while that of a capacitive hygrometer is 0% to 100%. 5.2 Dry and wet bulb method 5.2.1 Principle Two identical mercury thermometers are installed in metal sleeves, and the ball part of the mercury thermometers has double radiation protection tubes. The top of the set is equipped with a fan driven by clockwork or electricity. Once activated, the fan draws air evenly through the sleeve, exposing the bulb to an airflow of ≥2.5 m/s (up to 3 m/s for electric models). The temperature of the dry and wet bulb thermometers is then measured, and the relative humidity of the air is calculated based on the temperature difference between the two thermometers. 5.2.2 Instruments The instruments used in this method are as follows: ——Mechanical ventilation psychrometer: the minimum division of the temperature scale is not greater than 0.2°C, and the measurement accuracy is ±3%; ——Electric ventilation psychrometer: the minimum score of the temperature scale is not greater than 0.2°C, and the measurement accuracy is ±3%. 5.2.3 Measurement procedures The measurement procedures shall be carried out as follows: a) The arrangement of measuring points is in accordance with the provisions of A.2; b) Correction of the working time of the ventilator of mechanical ventilation psychrometer: operate according to the instruction manual, and the total working time of the ventilator shall not be less than 6 min.
Contents Foreword i Introduction i 1 Scope 2 Normative references 3 Terms and definitions 4 Air temperature 5 Relative humidity 6 Wind speed (electronic anemometer method) 7 Fresh air volume 8 Noise (digital sound level meter method) 9 Illuminance (illuminance meter method) 10 Natural daylight factor 11 Atmospheric pressure (barometer method) 12 Radiant heat 13 Thermal comfort 14 Electromagnetic radiation (broadband omnidirectional field strength meter method) 15 Ultraviolet radiation (ultraviolet spectrum analysis dosimetry method) 16 Radon concentration in the air 17 Pool water temperature (thermometer method) 18 Pool water transparency Annex A (Normative) Requirements for on-site detection sampling points Annex B (informative) Environmental background and toxicity levels of tracer gases
Referred in GB/T 18204.1-2025:
*GB/T 18049-2017 Ergonomics of the thermal environment―Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
*GB/T 18883-2022 Standards for indoor air quality
*HJ/T 10.2-1996 Guideline on management of radioactive environmental Protection electromagnetic radiation monitoring Instruments and Methods
*HJ 1212-2021 Measurement methods for determination of radon in environmental air
*JGJ/T 309-2013 The Standard of the Measurement and Evaluation for Efficiency of Building Ventilation
Code of China
Standard
GB/T 18204.1-2025  Examination methods for public places—Part 1: Physical indicators (English Version)
Standard No.GB/T 18204.1-2025
Statusvalid
LanguageEnglish
File FormatPDF
Word Count16500 words
Price(USD)495.0
Implemented on2025-12-1
Deliveryvia email in 1~3 business day
Detail of GB/T 18204.1-2025
Standard No.
GB/T 18204.1-2025
English Name
Examination methods for public places—Part 1: Physical indicators
Chinese Name
公共场所卫生检验方法 第1部分:物理性指标
Chinese Classification
C51
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-05-30
Implemented on
2025-12-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 18204.1-2013 Examination methods for public places - Part 1: Physical parameters
Language
English
File Format
PDF
Word Count
16500 words
Price(USD)
495.0
Keywords
GB/T 18204.1-2025, GB 18204.1-2025, GBT 18204.1-2025, GB/T18204.1-2025, GB/T 18204.1, GB/T18204.1, GB18204.1-2025, GB 18204.1, GB18204.1, GBT18204.1-2025, GBT 18204.1, GBT18204.1
Introduction of GB/T 18204.1-2025
GB/T 18204.1-2025 Examination methods for public places – Part 1: Physical indicators 1 Scope This document describes the methods for measuring physical indicators in public places. This document is applicable to the measurement of physical indicators in public places. Other places, such as residential rooms and other indoor environments, should refer to this document for guidance. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 18049 Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria GB/T 18883 Standards for indoor air quality HJ/T 10.2 Guideline on management of radioactive environmental protection - Electromagnetic radiation monitoring instruments and methods HJ 1212 Measurement methods for determination of radon in environmental air JGJ/T 309 The standard of the measurement and evaluation for efficiency of building ventilation ISO 7726 Ergonomics of the thermal environment - Instruments for measuring physical quantities ISO/TS 14415:2005 Ergonomics of the thermal environment - Application of International Standards to people with special requirements 3 Terms and definitions No terms and definitions are listed in this document. 4 Air temperature 4.1 Liquid-in-glass thermometer method 4.1.1 Principle The liquid-in-glass thermometer is composed of a thin-walled temperature sensing bulb containing the thermometer liquid and a thin glass tube sealed and connected with the temperature sensing bulb. The change of air temperature will cause the temperature change of the temperature sensing bulb, and the liquid volume in the temperature sensing bulb will change accordingly. When the temperature of the temperature sensing bulb increases, the liquid expands and the liquid column in the thin tube rises; and vice versa. The thin glass tube is graduated to indicate the height of the liquid column inside the tube, and the liquid column height reading accurately indicates the temperature of the temperature sensing bulb. 4.1.2 Instruments The instruments used in this method are as follows: ——Liquid-in-glass thermometer (minimum scale division not exceeding 0.2°C, measurement accuracy ±0.5°C); ——Thermometer hanging bracket. 4.1.3 Measurement procedures Measurement procedures shall be carried out as follows: a) The layout of measuring points shall comply with the provisions of A.2, Annex A; b) Readings shall be taken after 5 minutes. When taking readings, first read the decimal part and then the integer. The line of sight shall be perpendicular to the thermometer scale. For mercury thermometers, readings shall be taken at the highest point of the convex surface; for alcohol thermometers, readings shall be taken at the lowest point of the concave surface. c) Readings shall be taken quickly and accurately to avoid the influence of human breath on the accuracy of the readings; d) Due to the thermal after-effect of glass, the zero point position of the liquid-in-glass thermometer shall be frequently calibrated with a standard thermometer. If there is a displacement at the zero point, the displacement value shall be added to the reading; e) When exposed to sunlight or other thermal radiation, the temperature sensing bulb shall be shielded from heat when necessary to prevent contact with body parts such as hands. 4.1.4 Result calculation Temperatures shall be calculated using Equations (1) and (2). tactual = tmeasured + d (1) where, tactual——the actual temperature, °C. tmeasured——the measured temperature, °C. d——the zero displacement value, °C. d = a - b (2) where, a——the zero point shown by thermometer; b——the zero point position of standard thermometer calibration. 4.1.5 Result expression The measurement result of an area is given as the arithmetic mean of the measured values of the measuring points in the area. 4.1.6 Measuring range Air temperature: -0°C ~ 50°C. 4.2 Digital display thermometer 4.2.1 Principle PN junction thermistor, thermocouple, platinum resistor, etc. are used as the temperature sensor of the thermometer. The sensors generate electrical signals in response to temperature changes, which are then amplified and converted by an A/D converter before being directly displayed by the display as air temperature. 4.2.2 Instrument Digital display thermometer: minimum resolution of 0.1°C, measurement accuracy of ±0.5°C. 4.2.3 Measurement procedures The measurement procedures shall be carried out as follows: a) Perform in-service verification and pre-use calibration of the instrument as required; b) The arrangement of measuring points is in accordance with the provisions of A.2; c) Operate the instrument in accordance with the instrument manual; d) Read the temperature value after the reading on the display stabilizes. 4.2.4 Measuring range Air temperature: 0°C ~ 50°C; 5 Relative humidity 5.1 Resistance capacitance method 5.1.1 Principle Humidity is measured by utilizing the characteristic of moisture-sensitive elements, whose resistance and capacitance values change according to a certain pattern in response to changes in environmental humidity. 5.1.2 Instruments Various hygrometers using resistive or capacitive humidity sensors (at 25°C, the maximum allowable error is not greater than ±5%). 5.1.3 Measurement procedures The measurement procedures shall be carried out as follows: a) The arrangement of measuring points is in accordance with the provisions of A.2; b) The instrument is operated according to the instruction manual, and the relative humidity value is directly read out after the indicated value of the instrument is stable; c) The humidity-sensitive part of the humidity sensor of the instrument shall not be touched by hands, and shall be protected from dust pollution, harmful gas corrosion or condensation. 5.1.4 Measuring range Under conditions of 0°C ~ 60°C, the measurement range of a resistive hygrometer is 10% to 90%, while that of a capacitive hygrometer is 0% to 100%. 5.2 Dry and wet bulb method 5.2.1 Principle Two identical mercury thermometers are installed in metal sleeves, and the ball part of the mercury thermometers has double radiation protection tubes. The top of the set is equipped with a fan driven by clockwork or electricity. Once activated, the fan draws air evenly through the sleeve, exposing the bulb to an airflow of ≥2.5 m/s (up to 3 m/s for electric models). The temperature of the dry and wet bulb thermometers is then measured, and the relative humidity of the air is calculated based on the temperature difference between the two thermometers. 5.2.2 Instruments The instruments used in this method are as follows: ——Mechanical ventilation psychrometer: the minimum division of the temperature scale is not greater than 0.2°C, and the measurement accuracy is ±3%; ——Electric ventilation psychrometer: the minimum score of the temperature scale is not greater than 0.2°C, and the measurement accuracy is ±3%. 5.2.3 Measurement procedures The measurement procedures shall be carried out as follows: a) The arrangement of measuring points is in accordance with the provisions of A.2; b) Correction of the working time of the ventilator of mechanical ventilation psychrometer: operate according to the instruction manual, and the total working time of the ventilator shall not be less than 6 min.
Contents of GB/T 18204.1-2025
Contents Foreword i Introduction i 1 Scope 2 Normative references 3 Terms and definitions 4 Air temperature 5 Relative humidity 6 Wind speed (electronic anemometer method) 7 Fresh air volume 8 Noise (digital sound level meter method) 9 Illuminance (illuminance meter method) 10 Natural daylight factor 11 Atmospheric pressure (barometer method) 12 Radiant heat 13 Thermal comfort 14 Electromagnetic radiation (broadband omnidirectional field strength meter method) 15 Ultraviolet radiation (ultraviolet spectrum analysis dosimetry method) 16 Radon concentration in the air 17 Pool water temperature (thermometer method) 18 Pool water transparency Annex A (Normative) Requirements for on-site detection sampling points Annex B (informative) Environmental background and toxicity levels of tracer gases
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 18204.1-2025, GB 18204.1-2025, GBT 18204.1-2025, GB/T18204.1-2025, GB/T 18204.1, GB/T18204.1, GB18204.1-2025, GB 18204.1, GB18204.1, GBT18204.1-2025, GBT 18204.1, GBT18204.1