2026-3-18 216.73.216.153
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 22390.5-2026
GB/T 22390.5-2026   Control and protection equipment of high-voltage direct current (HVDC) transmission system—Part 5: DC line fault location device (English Version)
Standard No.: GB/T 22390.5-2026 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 12500 words Translation Price(USD):375.0 remind me the price change

Email:

Implemented on:2026-8-1 Delivery: via email in 1~5 business day

→ → →

,,2026-8-1,75C4F96829F460771770337773960
Standard No.: GB/T 22390.5-2026
English Name: Control and protection equipment of high-voltage direct current (HVDC) transmission system—Part 5: DC line fault location device
Chinese Name: 高压直流输电系统控制与保护设备 第5部分:直流线路故障定位装置
Professional Classification: GB    National Standard
Source Content Issued by: SAMR, SAC
Issued on: 2026-01-28
Implemented on: 2026-8-1
Status: to be valid
Superseding:GB/T 22390.5-2008 Control and protection equipment of high-voltage direct current (HVDC) transmission system - Part 5: DC line fault location
GB/T 22390.5-2008E
Target Language: English
File Format: PDF
Word Count: 12500 words
Translation Price(USD): 375.0
Delivery: via email in 1~5 business day
GB/T 22390.5-2026 Control and protection equipment of high-voltage direct current (HVDC) transmission system—Part 5: DC line fault location device English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 13.220.10 CCS H 57 National Standard of the People's Republic of China ‌GB/T 22390.5-2026 Replaces GB/T 22390.5-2008 Control and protection equipment of high-voltage direct current (HVDC) transmission system - Part 5: DC line fault location device 高压直流输电系统控制与保护设备 第5部分:直流线路故障定位装置 Issue date: 2026-01-28 Implementation date: 2027-02-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword Introduction 1 Scope 2 Normative References 3 Terms and Definitions 4 Technical Requirements 5 Test Methods 6 Inspection Rules 7 Marking, Labels, and Instruction Manual 8 Packaging, Transport, and Storage 9 Completeness of Supply 10 Quality Assurance Control and Protection Equipment for High-Voltage Direct Current (HVDC) Transmission Systems — Part 5: DC Line Fault Locator 1 Scope This document specifies the technical requirements, test methods, inspection rules, packaging, transport, storage, marking, labels, instruction manual, completeness of supply, and quality assurance for DC line fault locators used in HVDC transmission systems. This document is applicable to DC line fault locators (hereinafter referred to as "equipment") installed at the station ends of HVDC transmission systems with voltage levels of ±500 kV and below. 2 Normative References The following documents contain provisions which, through normative reference in this text, constitute essential provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB/T 2887-2011 General Specification for Computer Field GB/T 2900.49 Electrotechnical Terminology — Power System Protection GB/T 4208-2017 Degrees of Protection Provided by Enclosures (IP Code) GB/T 7261-2016 Basic Test Methods for Relaying Protection and Security Automatic Equipment GB/T 9361-2011 Safety Requirements for Computer Field GB/T 9969 General Principles for Preparation of Instructions for Use of Industrial Products GB/T 11287-2000 Electrical Relays — Part 21: Vibration, Shock, Bump and Seismic Tests on Measuring Relays and Protection Equipment — Section One: Vibration Tests (Sinusoidal) GB/T 13498 Terminology for High-Voltage Direct Current (HVDC) Transmission GB/T 14537-1993 Shock and Bump Tests on Measuring Relays and Protection Equipment GB/T 14598.24 Measuring Relays and Protection Equipment — Part 24: Common Format for Transient Data Exchange (COMTRADE) for Power Systems GB/T 14598.26-2025 Measuring Relays and Protection Equipment — Part 26: Electromagnetic Compatibility Requirements GB/T 14598.27-2025 Measuring Relays and Protection Equipment — Part 27: Product Safety Requirements GB/T 17626.9-2011 Electromagnetic Compatibility (EMC) — Testing and Measurement Techniques — Pulse Magnetic Field Immunity Test GB/T 17626.10-2017 Electromagnetic Compatibility (EMC) — Testing and Measurement Techniques — Damped Oscillatory Magnetic Field Immunity Test GB/T 32890 IEC 61850 Engineering Application Model for Protection Relays DL/T 357-2019 Technical Specification for Transmission Line Travelling Wave Fault Location Equipment NB/T 10448-2020 Testing Specification for Transmission Line Travelling Wave Fault Location Equipment 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 2900.49 and GB/T 13498, and the following apply. 3.1 time synchronization system A system that uses a standard time source to provide a unified time synchronization signal to the DC line fault locator. 3.2 fault location A technique for determining the location of a fault on a transmission line using electrical quantities during the fault. NOTE: Also known as "fault distance measurement". 3.3 fault location error The deviation between the fault point measured by the fault locator and the actual fault point. 4 Technical Requirements 4.1 Environmental Conditions 4.1.1 Normal Service Atmospheric Conditions The normal service atmospheric conditions are as follows: a) Ambient temperature: -10°C to +55°C; b) Atmospheric pressure: 80 kPa to 110 kPa; c) Relative humidity: 5% to 95%. 4.1.2 Standard Test Atmospheric Conditions The standard test atmospheric conditions are as follows: a) Ambient temperature: +15°C to +35°C; b) Atmospheric pressure: 86 kPa to 106 kPa; c) Relative humidity: 45% to 75%. 4.1.3 Standard Test Atmospheric Conditions for Arbitration Tests The standard test atmospheric conditions for arbitration tests are as follows: a) Ambient temperature: +20°C ± 2°C; b) Atmospheric pressure: 86 kPa to 106 kPa; c) Relative humidity: 45% to 75%. 4.1.4 Other Requirements for the Service Environment 4.1.4.1 The service environment shall not have vibration and shock exceeding the limits specified in this document. 4.1.4.2 The service environment shall be free from gases and conductive media that cause corrosion or damage to insulation. For environments with fire or explosion hazards, the equipment shall have explosion-proof measures. 4.1.4.3 The service environment for indoor equipment shall have facilities for protection against rain, snow, wind, and sand. 4.1.4.4 Site safety requirements shall comply with Class B provisions of GB/T 9361-2011, and grounding resistance shall comply with Clause 5.8 of GB/T 2887-2011. 4.1.5 Extreme Range Limits of Environmental Temperature The extreme temperature limits for the equipment are -25°C and +70°C. Under transport, storage, and installation conditions, the equipment without applied excitation shall withstand temperatures within this range without undergoing irreversible damage. 4.1.6 Special Environmental Conditions When environmental conditions exceed those specified in 4.1.1 to 4.1.5, they shall be subject to agreement between the manufacturer and the user. 4.2 Power Supply 4.2.1 AC Power Supply Requirements for AC power supply are as follows: a) Rated voltage: 220 V, with allowable deviation -20% to +15%;
Code of China
Standard
GB/T 22390.5-2026  Control and protection equipment of high-voltage direct current (HVDC) transmission system—Part 5: DC line fault location device (English Version)
Standard No.GB/T 22390.5-2026
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count12500 words
Price(USD)375.0
Implemented on2026-8-1
Deliveryvia email in 1~5 business day
Detail of GB/T 22390.5-2026
Standard No.
GB/T 22390.5-2026
English Name
Control and protection equipment of high-voltage direct current (HVDC) transmission system—Part 5: DC line fault location device
Chinese Name
高压直流输电系统控制与保护设备 第5部分:直流线路故障定位装置
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR, SAC
Issued on
2026-01-28
Implemented on
2026-8-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 22390.5-2008 Control and protection equipment of high-voltage direct current (HVDC) transmission system - Part 5: DC line fault location
GB/T 22390.5-2008E
Language
English
File Format
PDF
Word Count
12500 words
Price(USD)
375.0
Keywords
GB/T 22390.5-2026, GB 22390.5-2026, GBT 22390.5-2026, GB/T22390.5-2026, GB/T 22390.5, GB/T22390.5, GB22390.5-2026, GB 22390.5, GB22390.5, GBT22390.5-2026, GBT 22390.5, GBT22390.5
Introduction of GB/T 22390.5-2026
GB/T 22390.5-2026 Control and protection equipment of high-voltage direct current (HVDC) transmission system—Part 5: DC line fault location device English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 13.220.10 CCS H 57 National Standard of the People's Republic of China ‌GB/T 22390.5-2026 Replaces GB/T 22390.5-2008 Control and protection equipment of high-voltage direct current (HVDC) transmission system - Part 5: DC line fault location device 高压直流输电系统控制与保护设备 第5部分:直流线路故障定位装置 Issue date: 2026-01-28 Implementation date: 2027-02-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword Introduction 1 Scope 2 Normative References 3 Terms and Definitions 4 Technical Requirements 5 Test Methods 6 Inspection Rules 7 Marking, Labels, and Instruction Manual 8 Packaging, Transport, and Storage 9 Completeness of Supply 10 Quality Assurance Control and Protection Equipment for High-Voltage Direct Current (HVDC) Transmission Systems — Part 5: DC Line Fault Locator 1 Scope This document specifies the technical requirements, test methods, inspection rules, packaging, transport, storage, marking, labels, instruction manual, completeness of supply, and quality assurance for DC line fault locators used in HVDC transmission systems. This document is applicable to DC line fault locators (hereinafter referred to as "equipment") installed at the station ends of HVDC transmission systems with voltage levels of ±500 kV and below. 2 Normative References The following documents contain provisions which, through normative reference in this text, constitute essential provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB/T 2887-2011 General Specification for Computer Field GB/T 2900.49 Electrotechnical Terminology — Power System Protection GB/T 4208-2017 Degrees of Protection Provided by Enclosures (IP Code) GB/T 7261-2016 Basic Test Methods for Relaying Protection and Security Automatic Equipment GB/T 9361-2011 Safety Requirements for Computer Field GB/T 9969 General Principles for Preparation of Instructions for Use of Industrial Products GB/T 11287-2000 Electrical Relays — Part 21: Vibration, Shock, Bump and Seismic Tests on Measuring Relays and Protection Equipment — Section One: Vibration Tests (Sinusoidal) GB/T 13498 Terminology for High-Voltage Direct Current (HVDC) Transmission GB/T 14537-1993 Shock and Bump Tests on Measuring Relays and Protection Equipment GB/T 14598.24 Measuring Relays and Protection Equipment — Part 24: Common Format for Transient Data Exchange (COMTRADE) for Power Systems GB/T 14598.26-2025 Measuring Relays and Protection Equipment — Part 26: Electromagnetic Compatibility Requirements GB/T 14598.27-2025 Measuring Relays and Protection Equipment — Part 27: Product Safety Requirements GB/T 17626.9-2011 Electromagnetic Compatibility (EMC) — Testing and Measurement Techniques — Pulse Magnetic Field Immunity Test GB/T 17626.10-2017 Electromagnetic Compatibility (EMC) — Testing and Measurement Techniques — Damped Oscillatory Magnetic Field Immunity Test GB/T 32890 IEC 61850 Engineering Application Model for Protection Relays DL/T 357-2019 Technical Specification for Transmission Line Travelling Wave Fault Location Equipment NB/T 10448-2020 Testing Specification for Transmission Line Travelling Wave Fault Location Equipment 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 2900.49 and GB/T 13498, and the following apply. 3.1 time synchronization system A system that uses a standard time source to provide a unified time synchronization signal to the DC line fault locator. 3.2 fault location A technique for determining the location of a fault on a transmission line using electrical quantities during the fault. NOTE: Also known as "fault distance measurement". 3.3 fault location error The deviation between the fault point measured by the fault locator and the actual fault point. 4 Technical Requirements 4.1 Environmental Conditions 4.1.1 Normal Service Atmospheric Conditions The normal service atmospheric conditions are as follows: a) Ambient temperature: -10°C to +55°C; b) Atmospheric pressure: 80 kPa to 110 kPa; c) Relative humidity: 5% to 95%. 4.1.2 Standard Test Atmospheric Conditions The standard test atmospheric conditions are as follows: a) Ambient temperature: +15°C to +35°C; b) Atmospheric pressure: 86 kPa to 106 kPa; c) Relative humidity: 45% to 75%. 4.1.3 Standard Test Atmospheric Conditions for Arbitration Tests The standard test atmospheric conditions for arbitration tests are as follows: a) Ambient temperature: +20°C ± 2°C; b) Atmospheric pressure: 86 kPa to 106 kPa; c) Relative humidity: 45% to 75%. 4.1.4 Other Requirements for the Service Environment 4.1.4.1 The service environment shall not have vibration and shock exceeding the limits specified in this document. 4.1.4.2 The service environment shall be free from gases and conductive media that cause corrosion or damage to insulation. For environments with fire or explosion hazards, the equipment shall have explosion-proof measures. 4.1.4.3 The service environment for indoor equipment shall have facilities for protection against rain, snow, wind, and sand. 4.1.4.4 Site safety requirements shall comply with Class B provisions of GB/T 9361-2011, and grounding resistance shall comply with Clause 5.8 of GB/T 2887-2011. 4.1.5 Extreme Range Limits of Environmental Temperature The extreme temperature limits for the equipment are -25°C and +70°C. Under transport, storage, and installation conditions, the equipment without applied excitation shall withstand temperatures within this range without undergoing irreversible damage. 4.1.6 Special Environmental Conditions When environmental conditions exceed those specified in 4.1.1 to 4.1.5, they shall be subject to agreement between the manufacturer and the user. 4.2 Power Supply 4.2.1 AC Power Supply Requirements for AC power supply are as follows: a) Rated voltage: 220 V, with allowable deviation -20% to +15%;
Contents of GB/T 22390.5-2026
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Contact us via WeChat
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 22390.5-2026, GB 22390.5-2026, GBT 22390.5-2026, GB/T22390.5-2026, GB/T 22390.5, GB/T22390.5, GB22390.5-2026, GB 22390.5, GB22390.5, GBT22390.5-2026, GBT 22390.5, GBT22390.5