2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 2423.34-2012
GB/T 2423.34-2012   Environmental testing - Part 2: Test methods - Test Z/AD: Composite temperature/humidity cyclic test (English Version)
Standard No.: GB/T 2423.34-2012 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5000 words Translation Price(USD):100.0 remind me the price change

Email:

Implemented on:2013-6-1 Delivery: via email in 1 business day

→ → →

2025-03-01,2025-3-1,2013-6-1,14113818191806D49D28ABA18A1D6
Standard No.: GB/T 2423.34-2012
English Name: Environmental testing - Part 2: Test methods - Test Z/AD: Composite temperature/humidity cyclic test
Chinese Name: 环境试验 第2部分:试验方法 试验Z/AD:温度/湿度组合循环试验
Chinese Classification: K04    Basic standards and general methods
Professional Classification: GB    National Standard
Source Content Issued by: AQSIQ;SAC
Issued on: 2012-12-31
Implemented on: 2013-6-1
Status: superseded
Superseded by:GB/T 2423.34-2024 Environmental testing—Part 2:Test methods—Test Z/AD: Composite temperature/humidity cyclic test
Superseded on:2025-3-1
Abolished on:2025-03-01
Superseding:GB/T 2423.34-2005 Environmental testing for electric and electronic products - Part 2: Test methods - Test Z/AD: Composite temeperature/humidity cyclic test
Target Language: English
File Format: PDF
Word Count: 5000 words
Translation Price(USD): 100.0
Delivery: via email in 1 business day
1 Scope GB/T 2423 provides a composite test procedure, primarily intended for component type specimens, to determine, in an accelerated manner, the resistance of specimens to the deteriorative effects of high temperature/humidity and cold conditions. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60068-1 Environmental Testing—Part 1: General and Guidance IEC 60068-2-30 Environmental Testing—Part 2-30: Tests—Test Db: Damp Heat, Cyclic (12 h+12 h Cycle) IEC 60068-2-78 Environmental Testing—Part 2-78: Tests—Test Cab: Damp Heat, Steady State 3 General 3.1 Description of the Test Test Z/AD is a cyclic temperature/humidity test which is designed to reveal defects in test specimens caused by "breathing" as distinct from the absorption of moisture. This test differs from other cyclic damp heat tests in that it derives its increased severity from: a) a greater number of temperature variations or "pumping" actions in a given time; b) a greater cyclic temperature range; c) a higher cyclic rate of change of temperature; d) the inclusion of a number of excursions to sub-zero temperatures. The accelerated breathing and the effect of the freezing of trapped water in cracks and fissures are the essential features of this composite test. It is emphasized, however, that the freezing effect will occur only if the fissure dimensions are large enough to allow the penetration of a coherent mass of water as is normally the case in fissures between seals and metal assemblies, or between seals and wire terminations. The degree of condensation will depend mainly upon the thermal time constant of the surface of the test specimens and may be negligible for very small specimens but copious for large specimens. Similarly, the breathing effect will be more apparent on specimens which contain relatively large air-filled or gas-filled voids, but again, the severity of the test will depend to some extent on the thermal characteristics of the specimens.
Foreword i 1 Scope 2 Normative References 3 General 3.1 Description of the Test 3.2 Application of the Test 4 Description of Test Chamber 4.1 Chamber for Exposure to Moisture 4.2 Chamber for Exposure to Cold 5 Severities 6 Testing Procedure 6.1 Preconditioning (see Figure 1) 6.2 Initial Measurements 6.3 Conditioning 6.4 Test Cycle 6.5 Final Measurements 7 Information to be Given in the Relevant Specification 8 Information to be Given in the Test Report Annex NA (Informative) Components of GB/T
GB/T 2423.34-2012 is referred in:
* QC/T 413-2002 Basic Technical Requirements for Automotive Electric Equipment
* GB/T 26149-2010 TPM Sensor Module based tire pressure monitoring systems for motor vehicles
*JB/T 12845-2016 Electrically driven compressor for automobile air conditioning
*GB/T 22068-2018 Electrically driven compressor assembly for automobile air conditioning
*GB/T 28046.4-2011 Road vehicles—Environmental conditions and testing for electrical and electronic equipment—Part 4:Climatic loads
*JB/T 11880.4-2014 Diesel Engines - Selective Catalytic Reduction (SCR) Systems - Part 4: Urea Solution Supply Pump
*QC/T 1082-2017 Electromotor for automobile electrical power steering
*QC/T 1083-2017 Controller for automobile electrical power steering
*QC/T 1175-2022 High voltage contactor for electric vehicles
*JB/T 11472-2013 Low-speed Vehicles Electrical Equipments - Technical Specification
*QC/T 727-2007 Instrument for automobile and motorcycle
*QC/T 727-2017 Instrument for automobile and motorcycle
*GB/T 2423.3-2016 Environmental testing―Part 2:Testing method―Test Cab:Damp heat,steady state
Code of China
Standard
GB/T 2423.34-2012  Environmental testing - Part 2: Test methods - Test Z/AD: Composite temperature/humidity cyclic test (English Version)
Standard No.GB/T 2423.34-2012
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count5000 words
Price(USD)100.0
Implemented on2013-6-1
Deliveryvia email in 1 business day
Detail of GB/T 2423.34-2012
Standard No.
GB/T 2423.34-2012
English Name
Environmental testing - Part 2: Test methods - Test Z/AD: Composite temperature/humidity cyclic test
Chinese Name
环境试验 第2部分:试验方法 试验Z/AD:温度/湿度组合循环试验
Chinese Classification
K04
Professional Classification
GB
ICS Classification
Issued by
AQSIQ;SAC
Issued on
2012-12-31
Implemented on
2013-6-1
Status
superseded
Superseded by
GB/T 2423.34-2024 Environmental testing—Part 2:Test methods—Test Z/AD: Composite temperature/humidity cyclic test
Superseded on
2025-3-1
Abolished on
2025-03-01
Superseding
GB/T 2423.34-2005 Environmental testing for electric and electronic products - Part 2: Test methods - Test Z/AD: Composite temeperature/humidity cyclic test
Language
English
File Format
PDF
Word Count
5000 words
Price(USD)
100.0
Keywords
GB/T 2423.34-2012, GB 2423.34-2012, GBT 2423.34-2012, GB/T2423.34-2012, GB/T 2423.34, GB/T2423.34, GB2423.34-2012, GB 2423.34, GB2423.34, GBT2423.34-2012, GBT 2423.34, GBT2423.34
Introduction of GB/T 2423.34-2012
1 Scope GB/T 2423 provides a composite test procedure, primarily intended for component type specimens, to determine, in an accelerated manner, the resistance of specimens to the deteriorative effects of high temperature/humidity and cold conditions. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60068-1 Environmental Testing—Part 1: General and Guidance IEC 60068-2-30 Environmental Testing—Part 2-30: Tests—Test Db: Damp Heat, Cyclic (12 h+12 h Cycle) IEC 60068-2-78 Environmental Testing—Part 2-78: Tests—Test Cab: Damp Heat, Steady State 3 General 3.1 Description of the Test Test Z/AD is a cyclic temperature/humidity test which is designed to reveal defects in test specimens caused by "breathing" as distinct from the absorption of moisture. This test differs from other cyclic damp heat tests in that it derives its increased severity from: a) a greater number of temperature variations or "pumping" actions in a given time; b) a greater cyclic temperature range; c) a higher cyclic rate of change of temperature; d) the inclusion of a number of excursions to sub-zero temperatures. The accelerated breathing and the effect of the freezing of trapped water in cracks and fissures are the essential features of this composite test. It is emphasized, however, that the freezing effect will occur only if the fissure dimensions are large enough to allow the penetration of a coherent mass of water as is normally the case in fissures between seals and metal assemblies, or between seals and wire terminations. The degree of condensation will depend mainly upon the thermal time constant of the surface of the test specimens and may be negligible for very small specimens but copious for large specimens. Similarly, the breathing effect will be more apparent on specimens which contain relatively large air-filled or gas-filled voids, but again, the severity of the test will depend to some extent on the thermal characteristics of the specimens.
Contents of GB/T 2423.34-2012
Foreword i 1 Scope 2 Normative References 3 General 3.1 Description of the Test 3.2 Application of the Test 4 Description of Test Chamber 4.1 Chamber for Exposure to Moisture 4.2 Chamber for Exposure to Cold 5 Severities 6 Testing Procedure 6.1 Preconditioning (see Figure 1) 6.2 Initial Measurements 6.3 Conditioning 6.4 Test Cycle 6.5 Final Measurements 7 Information to be Given in the Relevant Specification 8 Information to be Given in the Test Report Annex NA (Informative) Components of GB/T
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 2423.34-2012, GB 2423.34-2012, GBT 2423.34-2012, GB/T2423.34-2012, GB/T 2423.34, GB/T2423.34, GB2423.34-2012, GB 2423.34, GB2423.34, GBT2423.34-2012, GBT 2423.34, GBT2423.34