GB/T 2951.51-2008   Common test methods for insulating and sheathing materials of electric and optical cables - Part 51: Methods specific to filling compounds - Drop point - Separation of oil - Lower te (English Version)
Standard No.: GB/T 2951.51-2008 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 7000 words Translation Price(USD):170.0 remind me the price change

Email:

Implemented on:2009-4-1 Delivery: via email in 1 business day

→ → →

,,2009-4-1,141138181856904B4B72B00EF5733
Standard No.: GB/T 2951.51-2008
English Name: Common test methods for insulating and sheathing materials of electric and optical cables - Part 51: Methods specific to filling compounds - Drop point - Separation of oil - Lower te
Chinese Name: 电缆和光缆绝缘和护套材料通用试验方法 第51部分:填充膏专用试验方法 滴点 油分离 低温脆性 总酸值 腐蚀性23℃时的介电常数 23℃和100℃时的直流电阻率
Chinese Classification: K31    Low-voltage distribution electrical equipment
Professional Classification: GB    National Standard
Source Content Issued by: AQSIQ; SAC
Issued on: 2008-6-26
Implemented on: 2009-4-1
Status: valid
Superseding:GB/T 2951.10-1997 Common test methods for insulating and sheathing materials of electric cables Part 5: Methods specific to filling compounds Section one: Drop-point―Separation of oil―Lower temperature brittleness―Total acid number―Absence of corrosive components―Perm
Target Language: English
File Format: PDF
Word Count: 7000 words
Translation Price(USD): 170.0
Delivery: via email in 1 business day
1 General 1.1 Scope This part of GB/T 2951 specifies the test methods for filling compounds of electric and optical cables used with telecommunications equipment, including cables used in ships and in offshore applications This part of GB/T 2951 specifies the methods for drop-point, separation of oil, lower temperature brittleness, total acid number, absence of corrosive components, permittivity at 23 °C, d.c. resistivity at 23 °C and 100 °C. 1.2 Normative References The following normative document contains provisions which, through reference in this text, constitute provisions of this part of GB/T 2951. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent edition of the normative document indicated below. For undated references, the latest edition of the normative document referred to applies. GB/T 5654-2007 Insulating Liquids — Measurement of Relative Permittivity Dielectric Dissipation Factor (tanδ) and D.C. Resistivity (IEC 60247:2004, IDT) 2 Test Values Any test requirements which are given in this part may be modified by the relevant cable standard to suit the needs of a particular type of cable. 3 Applicability Conditioning values and testing parameters are either specified in the materials specifications or in the product specifications. 4 Drop-point Note: These tests are intended for classification purposes only.
Foreword II 1 General 1.1 Scope 1.2 Normative References 2 Terms and Definitions 3 Test Values 4 Applicability 5 Type Tests and Other Tests 6 Pre-conditioning 7 Median Value 8 Tensile Strength and Elongation at Break After Conditioning at Elevated Temperature 8.1 General 8.2 Conditioning Procedure 8.3 Tensile Strength and Elongation Tests After Conditioning at Elevated Temperature 8.4 Expression of Results 9 Wrapping Test After Conditioning at Elevated Temperature 9.1 General 9.2 Conditioning Procedure 9.3 Test Procedure 9.4 Evaluation of Results 10 Wrapping Test After Thermal Ageing in Air 10.1 General 10.2 Apparatus 10.3 Sampling 10.4 Ageing Procedure 10.5 Test Procedure 10.6 Evaluation of Results 11 Mass Increase of Insulation 11.1 General 11.2 Sampling 11.3 Test Procedure 11.4 Calculation Annex A (Normative) Long-term Stability Test Annex B (Normative) Test Method for Copper-catalyzed Oxidative Degradation of Polyolefin Insulated Conductors [Oxidation Induction Time (OIT) Test]
GB/T 2951.51-2008 is referred in:
*YD/T 839.1-2015 Filling compounds and flooding compounds for telecommunication cable and optical fibre cable Part 1:Test methods
Code of China
Standard
GB/T 2951.51-2008  Common test methods for insulating and sheathing materials of electric and optical cables - Part 51: Methods specific to filling compounds - Drop point - Separation of oil - Lower te (English Version)
Standard No.GB/T 2951.51-2008
Statusvalid
LanguageEnglish
File FormatPDF
Word Count7000 words
Price(USD)170.0
Implemented on2009-4-1
Deliveryvia email in 1 business day
Detail of GB/T 2951.51-2008
Standard No.
GB/T 2951.51-2008
English Name
Common test methods for insulating and sheathing materials of electric and optical cables - Part 51: Methods specific to filling compounds - Drop point - Separation of oil - Lower te
Chinese Name
电缆和光缆绝缘和护套材料通用试验方法 第51部分:填充膏专用试验方法 滴点 油分离 低温脆性 总酸值 腐蚀性23℃时的介电常数 23℃和100℃时的直流电阻率
Chinese Classification
K31
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2008-6-26
Implemented on
2009-4-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 2951.10-1997 Common test methods for insulating and sheathing materials of electric cables Part 5: Methods specific to filling compounds Section one: Drop-point―Separation of oil―Lower temperature brittleness―Total acid number―Absence of corrosive components―Perm
Language
English
File Format
PDF
Word Count
7000 words
Price(USD)
170.0
Keywords
GB/T 2951.51-2008, GB 2951.51-2008, GBT 2951.51-2008, GB/T2951.51-2008, GB/T 2951.51, GB/T2951.51, GB2951.51-2008, GB 2951.51, GB2951.51, GBT2951.51-2008, GBT 2951.51, GBT2951.51
Introduction of GB/T 2951.51-2008
1 General 1.1 Scope This part of GB/T 2951 specifies the test methods for filling compounds of electric and optical cables used with telecommunications equipment, including cables used in ships and in offshore applications This part of GB/T 2951 specifies the methods for drop-point, separation of oil, lower temperature brittleness, total acid number, absence of corrosive components, permittivity at 23 °C, d.c. resistivity at 23 °C and 100 °C. 1.2 Normative References The following normative document contains provisions which, through reference in this text, constitute provisions of this part of GB/T 2951. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent edition of the normative document indicated below. For undated references, the latest edition of the normative document referred to applies. GB/T 5654-2007 Insulating Liquids — Measurement of Relative Permittivity Dielectric Dissipation Factor (tanδ) and D.C. Resistivity (IEC 60247:2004, IDT) 2 Test Values Any test requirements which are given in this part may be modified by the relevant cable standard to suit the needs of a particular type of cable. 3 Applicability Conditioning values and testing parameters are either specified in the materials specifications or in the product specifications. 4 Drop-point Note: These tests are intended for classification purposes only.
Contents of GB/T 2951.51-2008
Foreword II 1 General 1.1 Scope 1.2 Normative References 2 Terms and Definitions 3 Test Values 4 Applicability 5 Type Tests and Other Tests 6 Pre-conditioning 7 Median Value 8 Tensile Strength and Elongation at Break After Conditioning at Elevated Temperature 8.1 General 8.2 Conditioning Procedure 8.3 Tensile Strength and Elongation Tests After Conditioning at Elevated Temperature 8.4 Expression of Results 9 Wrapping Test After Conditioning at Elevated Temperature 9.1 General 9.2 Conditioning Procedure 9.3 Test Procedure 9.4 Evaluation of Results 10 Wrapping Test After Thermal Ageing in Air 10.1 General 10.2 Apparatus 10.3 Sampling 10.4 Ageing Procedure 10.5 Test Procedure 10.6 Evaluation of Results 11 Mass Increase of Insulation 11.1 General 11.2 Sampling 11.3 Test Procedure 11.4 Calculation Annex A (Normative) Long-term Stability Test Annex B (Normative) Test Method for Copper-catalyzed Oxidative Degradation of Polyolefin Insulated Conductors [Oxidation Induction Time (OIT) Test]
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 2951.51-2008, GB 2951.51-2008, GBT 2951.51-2008, GB/T2951.51-2008, GB/T 2951.51, GB/T2951.51, GB2951.51-2008, GB 2951.51, GB2951.51, GBT2951.51-2008, GBT 2951.51, GBT2951.51