2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 50080-2002
GB/T 50080-2002   Standard for test method of performance on ordinary fresh concrete (English Version)
Standard No.: GB/T 50080-2002 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 12000 words Translation Price(USD):220.0 remind me the price change

Email:

Implemented on:2003-6-1 Delivery: via email in 1 business day

→ → →

,2017-4-1,2003-6-1,1411381817841547735BE9CD0C541
Standard No.: GB/T 50080-2002
English Name: Standard for test method of performance on ordinary fresh concrete
Chinese Name: 普通混凝土拌合物性能试验方法标准
Chinese Classification: Q13    Concrete, aggregate, plaster and mortar
Professional Classification: GB    National Standard
ICS Classification: 91.100.30 91.100.30    Concrete and concrete products 91.100.30
Source Content Issued by: MOC
Issued on: 2003-01-10
Implemented on: 2003-6-1
Status: superseded
Superseded by:GB/T 50080-2016 Standard for test method of performance on ordinary fresh concrete
Superseded on:2017-4-1
Superseding:GBJ 80-1985 Testing methods for the performance of ordinary concrete
Target Language: English
File Format: PDF
Word Count: 12000 words
Translation Price(USD): 220.0
Delivery: via email in 1 business day
1 General Provisions 1.0.1 This standard is formulated in order to further normalize concrete test methods, improve concrete test accuracy and test level, as well as have an uniform test method of performance on concrete mixture in inspecting or controlling the quality of concrete work or precast concrete unit. 1.0.2 This standard is applicable to the ordinary concrete mixture performance test in the construction engineering, including sampling, sample preparation, consistency test, setting time test, bleeding and pressure bleeding test, apparent density test, air content test and mixing proportion analysis test.1.0.3 As for the tests carried out according to the test methods in this standard, the test report shall include the following contents: 1 The contents submitted by the client: 1) Name of the client; 2) Name of engineering and construction position; 3) Names of the to-be-inspected items; 4) Variety, specification and producing area of raw materials as well as concrete mixing proportion; 5) Other contents to be illustrated. 2 The contents submitted by the testing unit: 1) Sample number; 2) Test date and time; 3) Name, model and number of instruments and equipments; 4) Ambient temperature and humidity; 5) Variety, specification and producing area of raw materials, concrete mixing proportion and corresponding test number; 6) Mixing mode; 7) Concrete strength grade; 8) Test results; 9) Other contents to be illustrated. 1.0.4 Test method of performance on ordinary concrete mixture shall not only conform to the requirements of this standard, but also those in the current national compulsory standards. 2 Sampling and Sample Preparation 2.1 Sampling 2.1.1 The same group of concrete mixture shall be selected from the same tray or the same vehicle of concrete. The sampling amount shall be more than 1.5 times of the amount required in the test and should not be less than 20L. 2.1.2 The sampling of concrete mixture shall be representative, and multiple sampling methods should be adopted. Generally, samples are selected from 1/4, 1/2 and 3/4 respectively of the same tray or the same vehicle of concrete; interval between the first sampling and the last sampling should not exceed 15 minutes; then the samples shall be mixed uniformly with hands. 2.1.3 The interval between the end of the sampling and each performance test should not exceed 5 minutes. 2.2 Sample Preparation
1 General Provisions 2 Sampling and Sample Preparation 2.1 Sampling 2.2 Sample Preparation 2.3 Test Record 3 Consistency Test 3.1 Slump and Slump Flow 3.2 Vebe Consistency 4 Setting Time Test 5 Bleeding and Pressure Bleeding Test 5.1 Bleeding Test 5.2 Pressure Bleeding Test 6 Apparent Density Test 7 Air Content Test 8 Mixing Proportion Analysis Test Annex A Compact Factor Method Wording Explanation
GB/T 50080-2002 is referred in:
* GB 50208-2011 Code for acceptance of construction quality of underground waterproof
* JGJ 55-2011 Specification for Mix Proportion Design of Ordinary Concrete
* GB 8076-2008 Concrete Admixtures
* GB/T 14902-2003 Ready-mixed concrete
* JC/T 986-2005 Cementitious grout
* GB 50204-2015 Code for acceptance of constructional quallty of concrete structures
* JGJ/T 221-2010 Technical specification for application of fiber reinforced concrete
* GB 50666-2011 Code for construction of concrete structures
* TB/T 3192-2008 Technical specification of cable grouts on post-prestressed concrete railway girder
* GB/T 50448-2015 Code for application technique of cementitious grout
* GB/T 50082-2009 Standard for test methods of long-term performance and durability of ordinary concrete
* GB 50550-2010 Code for acceptance of constructional guality of strengthening building structures
Code of China
Standard
GB/T 50080-2002  Standard for test method of performance on ordinary fresh concrete (English Version)
Standard No.GB/T 50080-2002
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count12000 words
Price(USD)220.0
Implemented on2003-6-1
Deliveryvia email in 1 business day
Detail of GB/T 50080-2002
Standard No.
GB/T 50080-2002
English Name
Standard for test method of performance on ordinary fresh concrete
Chinese Name
普通混凝土拌合物性能试验方法标准
Chinese Classification
Q13
Professional Classification
GB
ICS Classification
Issued by
MOC
Issued on
2003-01-10
Implemented on
2003-6-1
Status
superseded
Superseded by
GB/T 50080-2016 Standard for test method of performance on ordinary fresh concrete
Superseded on
2017-4-1
Abolished on
Superseding
GBJ 80-1985 Testing methods for the performance of ordinary concrete
Language
English
File Format
PDF
Word Count
12000 words
Price(USD)
220.0
Keywords
GB/T 50080-2002, GB 50080-2002, GBT 50080-2002, GB/T50080-2002, GB/T 50080, GB/T50080, GB50080-2002, GB 50080, GB50080, GBT50080-2002, GBT 50080, GBT50080
Introduction of GB/T 50080-2002
1 General Provisions 1.0.1 This standard is formulated in order to further normalize concrete test methods, improve concrete test accuracy and test level, as well as have an uniform test method of performance on concrete mixture in inspecting or controlling the quality of concrete work or precast concrete unit. 1.0.2 This standard is applicable to the ordinary concrete mixture performance test in the construction engineering, including sampling, sample preparation, consistency test, setting time test, bleeding and pressure bleeding test, apparent density test, air content test and mixing proportion analysis test.1.0.3 As for the tests carried out according to the test methods in this standard, the test report shall include the following contents: 1 The contents submitted by the client: 1) Name of the client; 2) Name of engineering and construction position; 3) Names of the to-be-inspected items; 4) Variety, specification and producing area of raw materials as well as concrete mixing proportion; 5) Other contents to be illustrated. 2 The contents submitted by the testing unit: 1) Sample number; 2) Test date and time; 3) Name, model and number of instruments and equipments; 4) Ambient temperature and humidity; 5) Variety, specification and producing area of raw materials, concrete mixing proportion and corresponding test number; 6) Mixing mode; 7) Concrete strength grade; 8) Test results; 9) Other contents to be illustrated. 1.0.4 Test method of performance on ordinary concrete mixture shall not only conform to the requirements of this standard, but also those in the current national compulsory standards. 2 Sampling and Sample Preparation 2.1 Sampling 2.1.1 The same group of concrete mixture shall be selected from the same tray or the same vehicle of concrete. The sampling amount shall be more than 1.5 times of the amount required in the test and should not be less than 20L. 2.1.2 The sampling of concrete mixture shall be representative, and multiple sampling methods should be adopted. Generally, samples are selected from 1/4, 1/2 and 3/4 respectively of the same tray or the same vehicle of concrete; interval between the first sampling and the last sampling should not exceed 15 minutes; then the samples shall be mixed uniformly with hands. 2.1.3 The interval between the end of the sampling and each performance test should not exceed 5 minutes. 2.2 Sample Preparation
Contents of GB/T 50080-2002
1 General Provisions 2 Sampling and Sample Preparation 2.1 Sampling 2.2 Sample Preparation 2.3 Test Record 3 Consistency Test 3.1 Slump and Slump Flow 3.2 Vebe Consistency 4 Setting Time Test 5 Bleeding and Pressure Bleeding Test 5.1 Bleeding Test 5.2 Pressure Bleeding Test 6 Apparent Density Test 7 Air Content Test 8 Mixing Proportion Analysis Test Annex A Compact Factor Method Wording Explanation
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 50080-2002, GB 50080-2002, GBT 50080-2002, GB/T50080-2002, GB/T 50080, GB/T50080, GB50080-2002, GB 50080, GB50080, GBT50080-2002, GBT 50080, GBT50080